A novel electrocautery-enhanced delivery system for one-step endoscopic ultrasound-guided drainage of the gallbladder and bile duct using a lumen-apposing metal stent: a feasibility study

被引:18
|
作者
Yoo, Hae Won [1 ,2 ]
Moon, Jong Ho [1 ,2 ]
Jo, Seok Jung [1 ,2 ]
Lee, Yun Nah [1 ,2 ]
Park, Jae Keun [1 ,2 ]
Lee, Tae Hoon [3 ,4 ]
Cha, Sang-Woo [5 ,6 ]
Cho, Young Deok [5 ,6 ]
Park, Sang-Heum [3 ,4 ]
Park, Se Ik [7 ]
Jeong, Seok [8 ,9 ]
Lee, Don Haeng [8 ,9 ]
机构
[1] SoonChunHyang Univ, Digest Dis Ctr, Sch Med, 170 Jomaru Ro, Bucheon 14584, South Korea
[2] SoonChunHyang Univ, Res Inst, Sch Med, Dept Internal Med, Bucheon, South Korea
[3] SoonChunHyang Univ, Digest Dis Ctr, Sch Med, Cheonan, South Korea
[4] SoonChunHyang Univ, Res Inst, Sch Med, Dept Internal Med, Cheonan, South Korea
[5] SoonChunHyang Univ, Digest Dis Ctr, Sch Med, Seoul, South Korea
[6] SoonChunHyang Univ, Res Inst, Sch Med, Dept Internal Med, Seoul, South Korea
[7] Taewoong Med, Dept Res & Dev, Ilsan, South Korea
[8] Inha Univ, Digest Dis Ctr, Coll Med, Incheon, South Korea
[9] Inha Univ, Res Inst, Coll Med, Dept Internal Med, Incheon, South Korea
关键词
D O I
10.1055/a-1301-1526
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background The use of a lumen-apposing metal stent (LAMS) capable of one-step endoscopic ultrasound-guided transmural drainage (EUS-TD) can increase the effectiveness of the procedure. We evaluated the newly developed electrocautery-enhanced (EC) delivery system with a LAMS for one-step EUS-guided gallbladder drainage (EUS-GBD) or choledochoduodenostomy (EUS-CDS). Methods In the animal experiment, an EC-LAMS was advanced into the gallbladder without prior tract dilation in four pigs. A conventional LAMS was inserted in another four pigs as a control group. After the animal experiment, 17 patients underwent EUS-TD using the EC-LAMS (EUS-GBD in 10 patients, EUS-CDS in 7). The primary outcome was the technical success rate. Results In the animal study, the mean procedure time was significantly shorter in the EC-LAMS group than in the conventional LAMS group. In the human study, the overall technical success rate was 94.1%, with one EUS-GBD failure. The clinical success rate was 100%. The overall adverse event rate was 17.6%. Conclusions One-step EUS-GBD or EUS-CDS using the novel EC-LAMS is a feasible approach that achieves a high success rate and maintains safety.
引用
收藏
页码:922 / 926
页数:5
相关论文
共 50 条
  • [41] Endoscopic ultrasound-guided transjejunal drainage of an obstructed afferent loop using a novel lumen-apposing metal stent
    Lakhtakia, Sundeep
    Chavan, Radhika
    Basha, Jahangeer
    Nabi, Zaheer
    Gupta, Rajesh
    Reddy, D. Nageshwar
    ENDOSCOPY, 2019, 51 (09) : E253 - E254
  • [42] Endoscopic ultrasound-guided choledochojejunostomy with a lumen-apposing metal stent: a shortcut for biliary drainage
    Tyberg, Amy
    Karia, Kunal
    Zerbo, Steven
    Sharaiha, Reem Z.
    Kahaleh, Michel
    ENDOSCOPY, 2015, 47 : E342 - E343
  • [43] Endoscopic ultrasound-guided transesophageal drainage of a mediastinal pancreatic pseudocyst using a novel lumen-apposing metal stent
    Gornals, J. B.
    Loras, C.
    Mast, R.
    Botargues, J. M.
    Busquets, J.
    Castellote, J.
    ENDOSCOPY, 2012, 44 : E211 - E212
  • [44] EUS-guided gallbladder drainage in patients with acute cholecystitis and high surgical risk using an electrocautery-enhanced lumen-apposing metal stent device
    Dollhopf, Markus
    Larghi, Alberto
    Will, Uwe
    Rimbas, Mihai
    Anderloni, Andrea
    Sanchez-Yague, Andres
    Teoh, Anthony Yuen Bun
    Kunda, Rastislav
    GASTROINTESTINAL ENDOSCOPY, 2017, 86 (04) : 636 - 643
  • [45] A comparison of novel electrocautery-enhanced lumen-apposing metal stents and plastic stents in endoscopic ultrasound-guided drainage of infected walled-off necrosis: a multicenter randomized study
    Moon, Jong Ho
    Park, Se Woo
    Lee, Yun Nah
    Lee, Sang Hyub
    Kim, Seong-Hun
    Lee, Dong Wook
    Cho, Chang Min
    Kim, Sung Bum
    Park, Chan Hyuk
    ENDOSCOPY, 2024, 56 (12) : 926 - 937
  • [46] Outcomes of a single-step endoscopic ultrasound-guided drainage of pancreatic-fluid collections using an electrocautery-enhanced coaxial lumen-apposing, self-expanding metal stent with and without fluoroscopy
    Olaiya, Babatunde
    Mekaroonkamol, Parit
    Li, Bai-Wen
    Massaad, Julia
    Vachaparambil, Cicily T.
    Xu, Jennifer
    Lamm, Vladamir
    Luo, Hui
    Shen, Shan-Shan
    Chen, Hui-Min
    Keilin, Steve
    Willingham, Field F.
    Cai, Qiang
    GASTROENTEROLOGY REPORT, 2020, 8 (06): : 425 - 430
  • [47] Resection of gallbladder polyps following endoscopic ultrasound-guided cholecystoduodenostomy using a lumen-apposing metal stent
    Tian, Li
    Yang, Yuanyuan
    Xiao, Dinghua
    Wang, Rui
    Li, Xiayu
    Shen, Shourong
    Wang, Xiaoyan
    ENDOSCOPY, 2018, 50 (10) : E307 - E308
  • [48] Endoscopic ultrasound-guided choledochoduodenostomy (EUS-CDS) using electrocautery-enhanced lumen-apposing metal stent: the easiest way to perform EUS-CDS?
    Schaefer, Marion
    Albouys, Jeremie
    Legros, Romain
    Sautereau, Denis
    Charissoux, Aurelie
    Lepetit, Hugo
    Jacques, Jeremie
    ENDOSCOPY, 2019, 51 (08) : E219 - E220
  • [49] Revolutionizing palliative care: Electrocautery-enhanced lumen-apposing metal stents in endoscopic-ultrasound-guided biliary drainage for malignant obstructions
    Onteddu, Nirmal Kumar Reddy
    Mareddy, Naga Sai Rasagna
    Vulasala, Sai Swarupa R.
    Onteddu, Jayabharath
    Virarkar, Mayur
    WORLD JOURNAL OF GASTROINTESTINAL SURGERY, 2024, 16 (07):
  • [50] Endoscopic ultrasound-guided cystesophagostomy using a lumen-apposing metal stent for endoscopic drainage of a large mediastinal cyst
    Sanchez-Luna, Sergio A.
    Rustagi, Tarun
    DIGESTIVE ENDOSCOPY, 2020, 32 (07) : 1117 - 1117