A novel electrocautery-enhanced delivery system for one-step endoscopic ultrasound-guided drainage of the gallbladder and bile duct using a lumen-apposing metal stent: a feasibility study

被引:17
|
作者
Yoo, Hae Won [1 ,2 ]
Moon, Jong Ho [1 ,2 ]
Jo, Seok Jung [1 ,2 ]
Lee, Yun Nah [1 ,2 ]
Park, Jae Keun [1 ,2 ]
Lee, Tae Hoon [3 ,4 ]
Cha, Sang-Woo [5 ,6 ]
Cho, Young Deok [5 ,6 ]
Park, Sang-Heum [3 ,4 ]
Park, Se Ik [7 ]
Jeong, Seok [8 ,9 ]
Lee, Don Haeng [8 ,9 ]
机构
[1] SoonChunHyang Univ, Digest Dis Ctr, Sch Med, 170 Jomaru Ro, Bucheon 14584, South Korea
[2] SoonChunHyang Univ, Res Inst, Sch Med, Dept Internal Med, Bucheon, South Korea
[3] SoonChunHyang Univ, Digest Dis Ctr, Sch Med, Cheonan, South Korea
[4] SoonChunHyang Univ, Res Inst, Sch Med, Dept Internal Med, Cheonan, South Korea
[5] SoonChunHyang Univ, Digest Dis Ctr, Sch Med, Seoul, South Korea
[6] SoonChunHyang Univ, Res Inst, Sch Med, Dept Internal Med, Seoul, South Korea
[7] Taewoong Med, Dept Res & Dev, Ilsan, South Korea
[8] Inha Univ, Digest Dis Ctr, Coll Med, Incheon, South Korea
[9] Inha Univ, Res Inst, Coll Med, Dept Internal Med, Incheon, South Korea
关键词
D O I
10.1055/a-1301-1526
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background The use of a lumen-apposing metal stent (LAMS) capable of one-step endoscopic ultrasound-guided transmural drainage (EUS-TD) can increase the effectiveness of the procedure. We evaluated the newly developed electrocautery-enhanced (EC) delivery system with a LAMS for one-step EUS-guided gallbladder drainage (EUS-GBD) or choledochoduodenostomy (EUS-CDS). Methods In the animal experiment, an EC-LAMS was advanced into the gallbladder without prior tract dilation in four pigs. A conventional LAMS was inserted in another four pigs as a control group. After the animal experiment, 17 patients underwent EUS-TD using the EC-LAMS (EUS-GBD in 10 patients, EUS-CDS in 7). The primary outcome was the technical success rate. Results In the animal study, the mean procedure time was significantly shorter in the EC-LAMS group than in the conventional LAMS group. In the human study, the overall technical success rate was 94.1%, with one EUS-GBD failure. The clinical success rate was 100%. The overall adverse event rate was 17.6%. Conclusions One-step EUS-GBD or EUS-CDS using the novel EC-LAMS is a feasible approach that achieves a high success rate and maintains safety.
引用
收藏
页码:922 / 926
页数:5
相关论文
共 50 条
  • [31] Pancreaticoduodenectomy following endoscopic ultrasound-guided choledochoduodenostomy with electrocautery-enhanced lumen-apposing stents an ACHBT - SFED study
    Gaujoux, Sebastien
    Jacques, Jeremie
    Bourdariat, Raphael
    Sulpice, Laurent
    Lesurtel, Mickael
    Truant, Stephanie
    Robin, Fabien
    Prat, Frederic
    Palazzo, Maxime
    Schwarz, Lilian
    Buc, Emmanuel
    Sauvanet, Alain
    Taibi, Abdelkader
    Napoleon, Bertrand
    HPB, 2021, 23 (01) : 154 - 160
  • [32] Peroral cholecystoscopy using a multibending ultraslim endoscope through a lumen-apposing metal stent for endoscopic ultrasound-guided gallbladder drainage: a feasibility study
    Yoo, Hae Won
    Moon, Jong Ho
    Lee, Yun Nah
    Song, Yeon Han
    Yang, Jae Kook
    Lee, Tae Hoon
    Cha, Sang-Woo
    Cho, Young Deok
    Park, Sang-Heum
    ENDOSCOPY, 2022, 54 (04) : 384 - 388
  • [33] Endoscopic ultrasound-guided gastronephrostomy using a lumen-apposing metal stent
    Horny, Ivo
    ENDOSCOPY, 2024, 56 : E447 - E447
  • [34] ELECTROCAUTERY-ENHANCED DELIVERY SYSTEM OF LUMEN APPOSING METAL STENT FOR EUS-GUIDED BILIARY AND GALLBLADDER DRAINAGE: A SINGLE-CENTER STUDY
    Robles-Medranda, Carlos
    Oleas, Roberto
    Alcivar-Vasquez, Juan M.
    Acosta, Ariana C. Lopez
    Sanchez-Carriel, Maria
    Puga-Tejada, Miguel
    Lukashok, Hannah P.
    GASTROINTESTINAL ENDOSCOPY, 2021, 93 (06) : AB260 - AB260
  • [35] A SINGLE CENTER EXPERIENCE OF NOVEL LUMEN-APPOSING METAL STENT FOR ENDOSCOPIC ULTRASOUND-GUIDED DRAINAGE
    Anderloni, A.
    Di Leo, M.
    Carrara, S.
    Loriga, A.
    Repici, A.
    DIGESTIVE AND LIVER DISEASE, 2016, 48 : E99 - E100
  • [36] Endoscopic ultrasound-guided choledocoduodenostomy with electrocautery-enhanced lumen-apposing metal stent for benign biliary obstruction: When all other options fail
    Fuentes-Valenzuela, Esteban
    de la Serna Higuera, Carlos
    Perez-Miranda, Manuel
    DIGESTIVE ENDOSCOPY, 2021, 33 (04) : 670 - 670
  • [37] Conversion of Percutaneous Cholecystostomy to Internal Transmural Gallbladder Drainage Using an Endoscopic Ultrasound-Guided, Lumen-Apposing Metal Stent
    Law, Ryan
    Grimm, Ian S.
    Stavas, Joseph M.
    Baron, Todd H.
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2016, 14 (03) : 476 - 480
  • [38] Endoscopic ultrasound-guided transrectal pelvic abscess drainage using a lumen-apposing metal stent
    Shah, Shawn L.
    Karadesh, Salem
    Dawod, Enad
    Saumoy, Monica
    Afaneh, Cheguevara
    Sharaiha, Reem Z.
    ENDOSCOPY, 2018, 50 (09) : E254 - E255
  • [39] Endoscopic ultrasound-guided cholecystostomy for resection of gallbladder polyps with lumen-apposing metal stent
    Shen, Yonghua
    Cao, Jun
    Zhou, Xiaoliang
    Zhang, Song
    Li, Juan
    Xu, Guifang
    Zou, Xiaoping
    Lu, Ying
    Yao, Yuling
    Wang, Lei
    MEDICINE, 2020, 99 (43)
  • [40] Endoscopic ultrasound-guided choledochoduodenostomy with pyloric occlusion by proximal flange of electrocautery-enhanced lumen-apposing metal stent: solving a rare adverse event
    Paduano, Danilo
    Auriemma, Francesco
    Spatola, Federica
    Lamonaca, Laura
    Repici, Alessandro
    Mangiavillano, Benedetto
    ENDOSCOPY, 2022, 54 : E918 - E919