A novel electrocautery-enhanced delivery system for one-step endoscopic ultrasound-guided drainage of the gallbladder and bile duct using a lumen-apposing metal stent: a feasibility study

被引:17
|
作者
Yoo, Hae Won [1 ,2 ]
Moon, Jong Ho [1 ,2 ]
Jo, Seok Jung [1 ,2 ]
Lee, Yun Nah [1 ,2 ]
Park, Jae Keun [1 ,2 ]
Lee, Tae Hoon [3 ,4 ]
Cha, Sang-Woo [5 ,6 ]
Cho, Young Deok [5 ,6 ]
Park, Sang-Heum [3 ,4 ]
Park, Se Ik [7 ]
Jeong, Seok [8 ,9 ]
Lee, Don Haeng [8 ,9 ]
机构
[1] SoonChunHyang Univ, Digest Dis Ctr, Sch Med, 170 Jomaru Ro, Bucheon 14584, South Korea
[2] SoonChunHyang Univ, Res Inst, Sch Med, Dept Internal Med, Bucheon, South Korea
[3] SoonChunHyang Univ, Digest Dis Ctr, Sch Med, Cheonan, South Korea
[4] SoonChunHyang Univ, Res Inst, Sch Med, Dept Internal Med, Cheonan, South Korea
[5] SoonChunHyang Univ, Digest Dis Ctr, Sch Med, Seoul, South Korea
[6] SoonChunHyang Univ, Res Inst, Sch Med, Dept Internal Med, Seoul, South Korea
[7] Taewoong Med, Dept Res & Dev, Ilsan, South Korea
[8] Inha Univ, Digest Dis Ctr, Coll Med, Incheon, South Korea
[9] Inha Univ, Res Inst, Coll Med, Dept Internal Med, Incheon, South Korea
关键词
D O I
10.1055/a-1301-1526
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background The use of a lumen-apposing metal stent (LAMS) capable of one-step endoscopic ultrasound-guided transmural drainage (EUS-TD) can increase the effectiveness of the procedure. We evaluated the newly developed electrocautery-enhanced (EC) delivery system with a LAMS for one-step EUS-guided gallbladder drainage (EUS-GBD) or choledochoduodenostomy (EUS-CDS). Methods In the animal experiment, an EC-LAMS was advanced into the gallbladder without prior tract dilation in four pigs. A conventional LAMS was inserted in another four pigs as a control group. After the animal experiment, 17 patients underwent EUS-TD using the EC-LAMS (EUS-GBD in 10 patients, EUS-CDS in 7). The primary outcome was the technical success rate. Results In the animal study, the mean procedure time was significantly shorter in the EC-LAMS group than in the conventional LAMS group. In the human study, the overall technical success rate was 94.1%, with one EUS-GBD failure. The clinical success rate was 100%. The overall adverse event rate was 17.6%. Conclusions One-step EUS-GBD or EUS-CDS using the novel EC-LAMS is a feasible approach that achieves a high success rate and maintains safety.
引用
收藏
页码:922 / 926
页数:5
相关论文
共 50 条
  • [1] Clinical evaluation of a novel electrocautery-enhanced delivery system for one step endoscopic ultrasound-guided drainage using a lumen-apposing metal stent
    Shin, I. S.
    Moon, J. H.
    Lee, Y. N.
    Min, C. W.
    Lee, J. W.
    Lee, T. H.
    Yang, J. K.
    Cha, S. W.
    Cho, Y. D.
    Park, S. H.
    [J]. JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2021, 36 : 60 - 60
  • [2] Endoscopic ultrasound-guided drainage of a pancreatic pseudocyst with a novel lumen-apposing metal stent on an electrocautery-enhanced delivery system
    Anderloni, Andrea
    Orellana, Franco
    Jovani, Manol
    Repici, Alessandro
    [J]. DIGESTIVE AND LIVER DISEASE, 2015, 47 (10) : E17 - E17
  • [3] Endoscopic ultrasound-guided transmural gallbladder drainage with a lumen-apposing metal stent using an electrocautery enhanced delivery system
    Kumta, Nikhil A.
    Passos, Marina Lordello
    Silva, Gustavo Luis Rodela
    Novikov, Aleksey
    Kahaleh, Michel
    [J]. ENDOSCOPY, 2016, 48 : E327 - E327
  • [4] Contralateral gallbladder perforation and hemoperitoneum caused by an electrocautery-enhanced lumen-apposing metal stent during endoscopic ultrasound-guided gallbladder drainage
    Su, Jiayi
    Liu, Chuntao
    Li, Peng
    Wu, Jing
    [J]. ENDOSCOPY, 2023, 55 : E42 - E43
  • [5] A NOVEL ELECTROCAUTERY-ENHANCED DELIVERY SYSTEM FOR ONE STEP EUS-GUIDED DRAINAGE AND ACCESS BY USING LUMEN-APPOSING METAL STENT: A PORCINE STUDY
    Moon, Jong Ho
    Lee, Yun Nah
    Choi, Hyun Jong
    Lee, Hyun Woo
    Lee, Tae Hoon
    Choi, Moon Han
    Cha, Sang-Woo
    Cho, Young Deok
    Park, Sang-Heum
    Lee, Don Haeng
    [J]. GASTROINTESTINAL ENDOSCOPY, 2018, 87 (06) : AB465 - AB465
  • [6] Afferent loop syndrome treated by endoscopic ultrasound-guided gastrojejunostomy, using a lumen-apposing metal stent with an electrocautery-enhanced delivery system
    Yamamoto, Kenjiro
    Tsuchiya, Takayoshi
    Tanaka, Reina
    Mitsuyoshi, Honjo
    Mukai, Shuntaro
    Nagakawa, Yuichi
    Itoi, Takao
    [J]. ENDOSCOPY, 2017, 49 (11) : E270 - E272
  • [7] Unveiling the potential of electrocautery-enhanced lumen-apposing metal stents in endoscopic ultrasound-guided biliary drainage
    Chisthi, Meer M.
    [J]. WORLD JOURNAL OF GASTROINTESTINAL SURGERY, 2024, 16 (07):
  • [8] Endoscopic drainage of a jejunopancreatic pseudocyst with an electrocautery-enhanced lumen-apposing metal stent
    Terauchi, Toshiaki
    Shinozaki, Satoshi
    Mori, Kiyoto
    Lefor, Alan Kawarai
    Shinozaki, Hiroharu
    [J]. ENDOSCOPY, 2019, 51 (04) : E67 - E68
  • [9] Endoscopic ultrasound-guided drainage of a post-hepatectomy abscess using a lumen-apposing self-expandable metal stent with electrocautery-enhanced delivery system
    Attili, Fabia
    Dang, Shyam
    Rimbas, Mihai
    Di Maurizio, Luca
    Ettorre, Giuseppe Maria
    Attili, Adolfo Francesco
    Larghi, Alberto
    [J]. ENDOSCOPY, 2016, 48 : E222 - E223
  • [10] A novel bipolar electrocautery-enhanced delivery system with a lumen-apposing metal stent for EUS-guided drainage: A porcine study
    Jo, Seok Jung
    Moon, Jong Ho
    Lee, Yun Nah
    Park, Jae Keun
    Lee, Tae Hoon
    Park, Sang-Heum
    Park, Se Ik
    Jeong, Seok
    Lee, Don Haeng
    [J]. JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES, 2023, 30 (02) : 263 - 268