Automated Instead of Manual Treatment Planning? A Plan Comparison Based on Dose-Volume Statistics and Clinical Preference

被引:36
|
作者
Vanderstraeten, Barbara [1 ,2 ]
Goddeeris, Bruno [1 ]
Vandecasteele, Katrien [1 ,2 ]
van Eijkeren, Marc [1 ,2 ]
De Wagter, Carlos [1 ,2 ]
Lievens, Yolande [1 ,2 ]
机构
[1] Ghent Univ Hosp, Dept Radiotherapy Oncol, De Pintelaan 185 RTP, B-9000 Ghent, Belgium
[2] Univ Ghent, Dept Radiotherapy & Expt Canc Res, Ghent, Belgium
关键词
MODULATED RADIATION-THERAPY; STEREOTACTIC BODY RADIOTHERAPY; AT-RISK; IMRT; HEAD; QUALITY; GENERATION; VMAT; OPTIMIZATION; VALIDATION;
D O I
10.1016/j.ijrobp.2018.05.063
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Automated planning aims to speed up treatment planning and improve plan quality. We compared manual planning with automated planning for lung stereotactic body radiation therapy based on dose-volume histogram statistics and clinical preference. Methods and Materials: Manual and automated intensity modulated radiation therapy plans were generated for 56 patients by use of software developed in-house and Pinnacle 9.10 Auto-Planning, respectively. Optimization times were measured in 10 patients, and the impact of the automated plan (AP) on the total treatment cost was estimated. For the remaining 46 patients, each plan was checked against our clinical objectives, and a pair-wise dose-volume histogram comparison was performed. Three experienced radiation oncologists evaluated each plan and indicated their preference. Results: APs reduced the average optimization time by 77.3% but only affected the total treatment cost by 3.6%. Three APs and 0 manual plans failed our clinical objectives, and 13 APs and 9 manual plans showed a minor deviation. APs significantly reduced D2% (2% of the volume receives a dose of at least D2%) for the spinal cord, esophagus, heart, aorta, and main stem bronchus (P <.05) while preserving target coverage. The radiation oncologists found > 75% of the APs clinically acceptable without any further fine-tuning. Conclusions: APs may help to create satisfactory treatment plans quickly and effectively. Because critical appraisal by qualified professionals remains necessary, there is no such thing as "fully automated" planning yet. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:443 / 450
页数:8
相关论文
共 50 条
  • [21] Impact of the delineation of the heart on dose-volume histograms in treatment planning of NSCLC
    Cuervers, C.
    Nestle, U.
    Schimek-Jasch, T.
    Wiehle, R.
    Koenig, R.
    Decknatel, A.
    Hoffmanns, H.
    Kuesters, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S318 - S318
  • [22] A Comparison of Head and Neck IMRT Plans Optimized with Biologically Based Versus Dose-Volume Based Objectives in a Commercial Treatment Planning System
    Myint, K.
    Pyakuryal, A.
    Gopalakrishnan, M.
    Sathiaseelan, V.
    Mittal, B.
    [J]. MEDICAL PHYSICS, 2009, 36 (06) : 2644 - +
  • [23] Accuracy of calculation of volumes for the evaluation of dose-volume histograms. Comparison of different treatment planning systems
    Fellner, C
    Sommer, B
    Siedhoff, N
    Potter, R
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 1998, 174 (07) : 345 - 349
  • [24] A Web-based Dose-volume Histogram Dashboard for Library-based Individualized Dose-constraints and Clinical Plan Evaluation
    Mallick, Indranil
    Saha, Saheli
    Arunsingh, Moses A.
    [J]. JOURNAL OF MEDICAL SYSTEMS, 2021, 45 (06)
  • [25] A Web-based Dose-volume Histogram Dashboard for Library-based Individualized Dose-constraints and Clinical Plan Evaluation
    Indranil Mallick
    Saheli Saha
    Moses A Arunsingh
    [J]. Journal of Medical Systems, 2021, 45
  • [26] Direct optimization of dose-volume histogram metrics in radiation therapy treatment planning
    Zhang, Tianfang
    Bokrantz, Rasmus
    Olsson, Jimmy
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (06)
  • [27] The dose-volume constraint satisfaction problem for inverse treatment planning with field segments
    Michalski, D
    Xiao, Y
    Censor, Y
    Galvin, JM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (04): : 601 - 616
  • [28] A method for the implementation of dose-volume objectives in gradient algorithms for inverse treatment planning
    Hristov, D
    Stavrev, P
    Sham, E
    Fallone, B
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1255 - 1255
  • [29] CT-guided intracavitary radiotherapy for cervical cancer: Comparison of conventional point a plan with clinical target volume-based three-dimensional plan using dose-volume parameters
    Shin, KH
    Kim, TH
    Cho, JK
    Kim, JY
    Park, SY
    Park, SY
    Kim, DY
    Chie, EK
    Pyo, HR
    Cho, KH
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (01): : 197 - 204
  • [30] Automated Clinical Treatment Planning for breast: from manual to auto planning in Clinical Practise
    Vella, A.
    Gallagher, A.
    Stubbs, L.
    Dodkins, R.
    Singh, H.
    Padmanaban, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1362 - S1362