Accuracy of calculation of volumes for the evaluation of dose-volume histograms. Comparison of different treatment planning systems

被引:0
|
作者
Fellner, C [1 ]
Sommer, B [1 ]
Siedhoff, N [1 ]
Potter, R [1 ]
机构
[1] Univ Vienna, Klin Strahlentherapie & Biol, Allgemeines Krankenhaus Wien, A-1090 Vienna, Austria
关键词
treatment planning; accuracy of calculations; volumes; dose-volume histiograms;
D O I
10.1007/BF03038347
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Modern 3-dimensional treatment planning systems on the basis of sectional imaging allow the calculation of volumes for organs of interest. The aim of this study is to investigate systematically the accuracy of calculations of volumes by the use of a phantom for 4 different treatment planning systems. Material and Method: The tests were done with a phantom with 5 cylindrical structures and 6 spherical shaped structures. After performing a CT-scan and reading the data into the planning systems the structures were contoured and the volumes were calculated in order to compare these values with the values calculated by mathematical equations. This was systematically done as a function of different parameters. Results: Comparing different methods of contouring showed:notable influence on the result. Parameters as number of calculation points or length of cylinders showed no significant differences. In summary, the mean deviations for cylinders were +7% for system A, -2% for B, -17% for C, and 0% for D. For larger spheres (radii between 5 and 2.5 cm) the mean deviations were -5% for A, +3% for B, +1% for C, and +5% for D. For smaller spheres (radii between 1.75 and 1.25 cm) the mean deviations were -14% for A, -2% for B, -10% for C, and 4% for D. Conclusion: Verifying results of planning systems is important for the daily routine, but it has to be taken into account, that small changes of the radius of a cylinder or sphere cause substantial volume changes. The differences are also caused by inaccuracies of the whole procedure, e.g., the CT study, the shape and dimensions of the cylinders and the spheres and the CT information and the delineariation of the structures.
引用
收藏
页码:345 / 349
页数:5
相关论文
共 50 条
  • [1] Berechnungsgenauigkeit von Volumina zur Evaluierung von Dosis-Volumen-HistogrammenVergleich verschiedener BestrahlungsplanungssystemeAccuracy of calculation of volumes for the evaluation of dose-volume histograms. Comparison of different treatment planning systems
    Claudia Fellner
    Brit Sommer
    Nicole Siedhoff
    Richard Pötter
    [J]. Strahlentherapie und Onkologie, 1998, 174 (7) : 345 - 349
  • [2] DOSE-VOLUME DISTRIBUTIONS - A NEW APPROACH TO DOSE-VOLUME HISTOGRAMS IN 3-DIMENSIONAL TREATMENT PLANNING
    NIEMIERKO, A
    GOITEIN, M
    [J]. MEDICAL PHYSICS, 1994, 21 (01) : 3 - 11
  • [3] Cumulative Histograms under Uncertainty: An Application to Dose-Volume Histograms in Radiotherapy Treatment Planning
    Gesualdi, Flavia
    Wahl, Niklas
    [J]. STATS, 2024, 7 (01): : 284 - 300
  • [4] Impact of the delineation of the heart on dose-volume histograms in treatment planning of NSCLC
    Cuervers, C.
    Nestle, U.
    Schimek-Jasch, T.
    Wiehle, R.
    Koenig, R.
    Decknatel, A.
    Hoffmanns, H.
    Kuesters, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S318 - S318
  • [5] DOSE-VOLUME HISTOGRAMS FOR 3-D RADIATION TREATMENT PLANNING
    DRZYMALA, RE
    HARMS, WB
    PURDY, JA
    [J]. MEDICAL PHYSICS, 1987, 14 (03) : 460 - 460
  • [6] Radiotherapy of liver metastases - Comparison of target volumes and dose-volume histograms employing CT- or MRI-based treatment planning
    Pech, Maciej
    Mohnike, Konrad
    Wieners, Gero
    Bialek, Ewa
    Ducleck, Oliver
    Seidensticker, Max
    Peters, Nils
    Wust, Peter
    Gademann, Guenher
    Ricke, Jens
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2008, 184 (05) : 256 - 261
  • [7] Independent Evaluation Of Dose-Volume Histogram (Dvh) Calculation Accuracy
    Moragues Femenia, S.
    Calvo-Ortega, J. F.
    Casals, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S465 - S465
  • [8] 3D-based virtual simulation in treatment planning for breast cancer patients: Description of accuracy and evaluation of dose-volume histograms
    Schiebe, M
    Pinkert, U
    Kornek, P
    Hennig, I
    Hoffmann, W
    [J]. RADIOLOGY, 2001, 221 : 173 - 173
  • [9] Dose-volume histograms can be interpreted in different ways
    Jayaraman, S
    Asbell, SO
    [J]. CANCER INVESTIGATION, 1997, 15 (06) : 611 - 613
  • [10] Comparison of dose-volume histograms of IMRT treatment plans for ethmoid sinus cancer computed by advanced treatment planning systems including Monte Carlo
    Paelinck, Leen
    De Smedt, Bart
    Reynaert, Nick
    Coghe, Marc
    De Gersem, Werner
    De Wagter, Carlos
    Vanderstraeten, Barbara
    Thierens, Hubert
    De Neve, Wilfried
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 (03) : 250 - 256