Determination of norepinephrine in small volume plasma samples by stable-isotope dilution gas chromatography-tandem mass spectrometry with negative ion chemical ionization

被引:39
|
作者
Kuhlenbeck, DL [1 ]
O'Neill, TP [1 ]
Mack, CE [1 ]
Hoke, SH [1 ]
Wehmeyer, KR [1 ]
机构
[1] Procter & Gamble Co, Pharmaceut, Hlth Care Res Ctr, Mason, OH 45040 USA
来源
JOURNAL OF CHROMATOGRAPHY B | 2000年 / 738卷 / 02期
关键词
norepinephrine;
D O I
10.1016/S0378-4347(99)00541-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A stable-isotope based gas chromatography-tandem mass spectrometry-negative ion chemical ionization method was developed for the determination of norepinephrine (NE) levels in small volumes (25-100 mu l) of plasma. NE was stabilized in plasma by the addition of semicarbazide and spiked with deuterium-labeled norepinephrine internal standard. The analytes were isolated from the plasma by solid-phase extraction using phenylborofiic acid columns and derivatized using pentafluoropropionic anhydride. The derivatized analytes were chromatographed on a capillary column and detected by tandem mass spectrometry with negative ion chemical ionization. Unparalleled sensitivity and selectivity were obtained using this detection scheme, allowing the unambiguous analysis of trace levels of NE in small-volume plasma samples. Linear standard curves were obtained for NE over a mass range from 1 to 200 pg per sample. The method had a limit of quantitation of 10 pg NE/ml plasma when using a 100-mu 1*1 sample aliquot (1 pg/sample). Accuracy for the analysis of plasma samples spiked with 10 to 200 pg NE/ml typically ranged from 100+/-10%, with RSD values of less than 108. The methodology was applied to determine the effect of clonidine on plasma NE levels in conscious spontaneously hypertensive rats. Administration of clonidine (30 mu g/kg) produced an similar to 80% reduction in plasma NE accompanied by a 30% reduction in heart and mean arterial pressure that persisted >90 min after drug administration. The ability to take multiple samples from individual rats allowed the time course for the effect of clonidine to be mapped out using only one group of animals. O 7000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:319 / 330
页数:12
相关论文
共 50 条
  • [41] An improved method for the measurement of the angiotensin-converting enzyme inhibitor lisinopril in human plasma by stable isotope dilution gas chromatography negative ion chemical ionization mass spectrometry
    Leis, HJ
    Fauler, G
    Raspotnig, G
    Windischhofer, W
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (08) : 650 - 653
  • [42] Determination of melamine and its analogues in egg by gas chromatography-tandem mass spectrometry using an isotope dilution technique
    Miao, H.
    Fan, S.
    Zhou, P. P.
    Zhang, L.
    Zhao, Y. F.
    Wu, Y. N.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2010, 27 (11): : 1497 - 1506
  • [43] Determination of Clotrimazole Residue in Animal-Derived Food by Gas Chromatography-Tandem Mass Spectrometry with Isotope Dilution
    Han C.
    Hu B.
    Li Z.
    Zhu Z.
    Shen Y.
    Zhou X.
    Science and Technology of Food Industry, 2021, 42 (05): : 216 - 220
  • [44] Determination of derivatized clenbuterol by use of gas chromatography and tandem mass spectrometry on an ion trap using negative ion chemical ionization
    Lee, J
    Lho, DS
    Kim, M
    Lee, W
    Kim, Y
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1998, 12 (19) : 1366 - 1372
  • [45] DETERMINATION OF LEAD IN URINE AND WHOLE-BLOOD BY STABLE-ISOTOPE DILUTION GAS-CHROMATOGRAPHY MASS-SPECTROMETRY
    AGGARWAL, SK
    KINTER, M
    HEROLD, DA
    CLINICAL CHEMISTRY, 1994, 40 (08) : 1494 - 1502
  • [46] DETERMINATION OF FLUMAZENIL IN PLASMA BY GAS CHROMATOGRAPHY-NEGATIVE ION CHEMICAL-IONIZATION MASS-SPECTROMETRY
    SONG, DM
    KHAYKIS, V
    KOHLHOF, K
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 663 (02): : 263 - 273
  • [47] DETERMINATION OF CLONAZEPAM IN HUMAN-PLASMA BY GAS CHROMATOGRAPHY NEGATIVE ION CHEMICAL IONIZATION MASS-SPECTROMETRY
    GARLAND, WA
    MIN, BH
    JOURNAL OF CHROMATOGRAPHY, 1979, 172 (APR): : 279 - 286
  • [48] Determination of alprazolam and α-hydroxyalprazolam in human plasma by gas chromatography/negative-ion chemical ionization mass spectrometry
    Hold, K.M.
    Crouch, D.J.
    Rollins, D.E.
    Wilkins, D.G.
    Canfield, D.V.
    Maes, R.A.
    Journal of Mass Spectrometry, 1996, 31 (09):
  • [49] Quantitative determination of rifampicin in aquatic products by stable isotope-dilution high liquid chromatography-tandem mass spectrometry
    Li, Qin
    Cao, Jingyuan
    Han, Gang
    Liu, Huan
    Yan, Jie
    Wu, Lidong
    Li, Jincheng
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (05)
  • [50] Determination of selenium stable isotopes by gas chromatography-mass spectrometry with negative chemical ionization
    Van, Dael, P.
    Barclay, D.
    Longet, K.
    Metairon, S.
    Fay, L.B.
    Journal of Chromatography B, 1998, 715 (02): : 341 - 347