Modified DPC for DFIG based Wind Power Generation under Unbalanced Grid-Voltage

被引:0
|
作者
Sun, Dan [1 ]
Guo, Xiaoming [1 ]
Shang, Lei [1 ]
He, Yikang [1 ]
机构
[1] Zhejiang Univ, Country Sch Elect Engn, Hangzhou 310027, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a modified direct power control (DPC) strategy for a doubly fed induction generator (DFIG) based wind power generation system under unbalanced grid-voltage conditions. The strategy is based on the investigation of the mathematic model and the composition of the instantaneous active and reactive power outputted by DFIG. It is found that, by applying a notch filter of two times of the grid frequency, the proposed DPC strategy is capable of the unbalanced fault ride through operation. By compensating the errors caused by DFIG parameter mismatch, the control robustness of the proposed DPC scheme has been further enhanced. Simulation results verified that the proposed strategy is simple in control structure and have excellent dynamic performance for the reason of avoiding the computation of the negative sequence component current, and therefore, the corresponding current control loops are unnecessary.
引用
收藏
页码:2299 / 2304
页数:6
相关论文
共 50 条
  • [41] Coordinated Control of a DFIG-Based Wind-Power Generation System with SGSC under Distorted Grid Voltage Conditions
    Yao, Jun
    Li, Qing
    Chen, Zhe
    Liu, Aolin
    ENERGIES, 2013, 6 (05): : 2541 - 2561
  • [42] Operation of Grid-Connected DFIG Under Unbalanced Grid Voltage Condition
    Zhou, Yi
    Bauer, Paul
    Ferreira, Jan A.
    Pierik, Jan
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2009, 24 (01) : 240 - 246
  • [43] Power and Current Limiting Control of Wind Turbines Based on PMSG Under Unbalanced Grid Voltage
    Liu, Jun
    Zhao, Chencong
    Xie, Zhouhua
    IEEE ACCESS, 2021, 9 : 9873 - 9883
  • [44] Direct Power Control for DFIG under Unbalanced and Harmonically Distorted Grid Voltage in Stationary Frame
    Song, Yipeng
    Nian, Heng
    2014 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2014, : 1500 - 1506
  • [45] Grid Connection Control of DFIG Wind Power Generation Based on PSCAD
    Zhou, Jie
    Ren, Yongfeng
    Li, Hanshan
    Wang, Zhihe
    An, Zhongquan
    Liu, Jinguo
    Hu, Hongbin
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [46] Enhancing the performance of grid synchronization in DFIG-based wind turbine under unbalanced grid conditions
    Ali Ghasemi
    Mohammad Hossein Refan
    Parviz Amiri
    Electrical Engineering, 2020, 102 : 1175 - 1194
  • [47] Enhancing the performance of grid synchronization in DFIG-based wind turbine under unbalanced grid conditions
    Ghasemi, Ali
    Refan, Mohammad Hossein
    Amiri, Parviz
    ELECTRICAL ENGINEERING, 2020, 102 (03) : 1175 - 1194
  • [48] Using of four-switch three-phase converter in the structure DPC of DFIG under unbalanced grid voltage condition
    Ali Izanlo
    S. Asghar Gholamian
    Mohammad Verij Kazemi
    Electrical Engineering, 2018, 100 : 1925 - 1938
  • [49] Using of four-switch three-phase converter in the structure DPC of DFIG under unbalanced grid voltage condition
    Izanlo, Ali
    Gholamian, S. Asghar
    Kazemi, Mohammad Verij
    ELECTRICAL ENGINEERING, 2018, 100 (03) : 1925 - 1938
  • [50] Control Strategy of Wind Power Converter Under Unbalanced Grid Voltage Condition
    Jiang, Chenhui
    Wang, Zhixin
    PROGRESS IN RENEWABLE AND SUSTAINABLE ENERGY, PTS 1 AND 2, 2013, 608-609 : 615 - 621