Power and Current Limiting Control of Wind Turbines Based on PMSG Under Unbalanced Grid Voltage

被引:10
|
作者
Liu, Jun [1 ]
Zhao, Chencong [1 ]
Xie, Zhouhua [2 ]
机构
[1] Xian Univ Technol, Coll Automat, Xian 710048, Peoples R China
[2] Xian Thermal Power Res Inst Co Ltd, Xian 710032, Peoples R China
关键词
Voltage control; Limiting; Licenses; Fluctuations; Wind turbines; Wind power generation; Rotors; Unbalanced grid voltage; peak current; current limiting control; rotor kinetic energy; reactive power support; CONTROL SCHEME; ACTIVE POWER; SYSTEMS; ENHANCEMENT; CAPABILITY; SUPPORT;
D O I
10.1109/ACCESS.2021.3049839
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Unbalanced grid voltage sags are the severe challenge for wind power generation system which connected to the grid successfully. The dc bus voltage and output power will fluctuate under unbalanced grid voltage. Moreover, the voltage sags will lead to the increase of peak current, which will bring potential safety hazards to the operation of wind power system. This paper proposes a simple current limiting control scheme without auxiliary equipment, which based on the detailed analysis of the excessive peak current. In this scheme, the machine side converter (MSC) controller adjusts the electromagnetic power according to the power transmitted to the grid by the grid side converter (GSC). Meanwhile, it converts the unbalanced power on the dc-link into the rotor kinetic energy, avoiding the dc-link overvoltage. The GSC controller can not only ensure that the three-phase inverter currents are in the maximum safe range that the converters can bear, but also provide reactive power support for the grid. Furthermore, the fluctuations on dc bus voltage and output power can be eliminated effectively by using the GSC controller. The feasibility of the proposed scheme and the superiority over the traditional control schemes have been verified by simulations under different types of unbalanced voltage.
引用
下载
收藏
页码:9873 / 9883
页数:11
相关论文
共 50 条
  • [1] Control of PMSG Wind Turbines Based on Reduced Order Resonant Controllers Under Unbalanced Grid Voltage Conditions
    Dong, Shuhui
    Li, Yonggang
    Wang, Aimeng
    Xi, Wenyuan
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS (PEDS 2015), 2015, : 326 - 329
  • [2] Voltage Support Control Strategy of PMSG Wind Turbines During Unbalanced Grid Fault
    Su, Xiangxue
    Wang, Zhihao
    Ding, Lei
    Jia, Chunjiang
    2020 5TH ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2020), 2020, : 678 - 683
  • [3] A Novel Current Control Scheme of Grid Converters for Small PMSG Wind Turbines under Grid Voltage Distortion
    Thanh Hai Nguyen
    Lee, Dong-Choon
    2012 IEEE POWER ELECTRONICS AND MACHINES IN WIND APPLICATIONS (PEMWA), 2012,
  • [4] Flexible power/current control of wind power grid connected converter with current limitation under unbalanced grid voltage
    Zhao, Chen-Cong
    Liu, Jun
    Xie, Zhou-Hua
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2022, 26 (01): : 137 - 148
  • [5] Direct Power Control of Doubly-Fed-Induction-Generator-Based Wind Turbines Under Unbalanced Grid Voltage
    Abad, Gonzalo
    Angel Rodriguez, Miguel
    Iwanski, Grzegorz
    Poza, Javier
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (02) : 442 - 452
  • [6] Optimized Control for PMSG Wind Turbine Systems under Unbalanced and Distorted Grid Voltage Scenarios
    Abo-Khalil, Ahmed G.
    Alobaid, Mohammad
    SUSTAINABILITY, 2023, 15 (12)
  • [7] Negative Sequence Current Injection Control Algorithm Compensating for Unbalanced PCC Voltage in Medium Voltage PMSG Wind Turbines
    Kang, Jayoon
    Han, Daesu
    Suh, Yongsug
    Jung, Byoungchang
    Kim, Jeongjoong
    Park, Jonghyung
    Choi, Youngjoon
    2014 INTERNATIONAL POWER ELECTRONICS CONFERENCE (IPEC-HIROSHIMA 2014 - ECCE-ASIA), 2014, : 1185 - 1192
  • [8] Current-based direct power control of a DFIG under unbalanced grid voltage
    Farshadnia, Mohammad
    Taher, Seyed Abbas
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 62 : 571 - 582
  • [9] Ride-through of PMSG Wind Power System Under the Distorted and Unbalanced Grid Voltage Dips
    Sim, Jun-Bo
    Kim, Ki-Cheol
    Son, Rak-Won
    Oh, Joong-Ki
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2012, 7 (06) : 898 - 904
  • [10] Control Strategy of Wind Power Converter Under Unbalanced Grid Voltage Condition
    Jiang, Chenhui
    Wang, Zhixin
    PROGRESS IN RENEWABLE AND SUSTAINABLE ENERGY, PTS 1 AND 2, 2013, 608-609 : 615 - 621