Optimized Control for PMSG Wind Turbine Systems under Unbalanced and Distorted Grid Voltage Scenarios

被引:1
|
作者
Abo-Khalil, Ahmed G. [1 ,2 ]
Alobaid, Mohammad [3 ]
机构
[1] Univ Sharjah, Coll Engn, Sustainable & Renewable Energy Engn Dept, Sharjah, U Arab Emirates
[2] Assiut Univ, Coll Engn, Dept Elect Engn, Assiut 71515, Egypt
[3] Majmaah Univ, Coll Engn, Dept Mech & Ind Engn, Almajmaah 11952, Saudi Arabia
关键词
wind turbine; renewable energy; synchronous generator; total harmonic distortion; current harmonics; CONNECTED INVERTER; POWER; DFIG; SYNCHRONIZATION; DESIGN; SCHEME; FARMS;
D O I
10.3390/su15129552
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Wind energy is one of the fastest growing energies due to its feasible cost and environment friendly nature, where there is no emission of waste or greenhouse gases emission. Wind energy systems should be connected to the electric utility to avoid the effects of the intermittent nature of these sources. One of the main problems of the utility integration of wind turbines is the unbalanced voltage of the utility grid. Many efforts have been made to remedy the effects of the unbalanced grid voltage connected with the electric utility. This research points out the need for more accurate and robust controllers, such as those mentioned in this paper. A novel combination strategy is presented in this paper to overcome the inherent imbalance in the electric utility voltages when used in combination with a permanent magnet synchronous generator (PMSG). This novel technique is designed to adapt the positive sequence of the dq-axis of the output current from the PMSG to extract the maximum power available from a wind turbine. Meanwhile, the negative sequence component is used to improve the quality of the output current from a wind turbine. A current controller is introduced in the grid side converter to compensate for the effects of the 2nd and 6th components of the output currents. Using these controllers reduces all dominant components in the output currents from wind turbines and permits a robust tracker for the maximum power available. A detailed simulation and experimental studies are introduced in this paper to show the controller operation under different operating conditions. The simulation and experimental results from the novel proposed strategy show its superiority in fully remedying the effect of unbalanced grid voltages.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Modeling and control of unbalanced and distorted grid voltage of grid-connected DFIG wind turbine
    Abo-Khalil, Ahmed G.
    Alharbi, Walied
    Al-Qawasmi, Abdel-Rahman
    Alobaid, Mohammad
    Alarifi, Ibrahem
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2021, 31 (05)
  • [2] Ride-through of PMSG Wind Power System Under the Distorted and Unbalanced Grid Voltage Dips
    Sim, Jun-Bo
    Kim, Ki-Cheol
    Son, Rak-Won
    Oh, Joong-Ki
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2012, 7 (06) : 898 - 904
  • [3] Power and Current Limiting Control of Wind Turbines Based on PMSG Under Unbalanced Grid Voltage
    Liu, Jun
    Zhao, Chencong
    Xie, Zhouhua
    IEEE ACCESS, 2021, 9 : 9873 - 9883
  • [4] Improved Power Control of DFIGs Driven by Wind Turbine under Unbalanced Grid Voltage
    Shehata, E. G.
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2023, 19 (01) : 325 - 340
  • [5] Direct power control on the DFIG wind turbine under unbalanced grid voltage conditions
    Guo, Xiaoming
    He, Yikang
    He, Benteng
    Hu, Jiabing
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2008, 32 (13): : 86 - 91
  • [6] An Improved Control Method for a DFIG in a Wind Turbine under an Unbalanced Grid Voltage Condition
    Lee, Sol-Bin
    Lee, Kyo-Beum
    Lee, Dong-Choon
    Kim, Jang-Mok
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2010, 5 (04) : 614 - 622
  • [7] Improved Power Control of DFIGs Driven by Wind Turbine under Unbalanced Grid Voltage
    E. G. Shehata
    Journal of Electrical Engineering & Technology, 2024, 19 : 325 - 340
  • [8] Control of back-to-back PWM converters for DFIG wind turbine systems under unbalanced grid voltage
    Abo-Khalil, Ahmed G.
    Lee, Dong-Choon
    Jang, Jeong-Ik
    2007 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, PROCEEDINGS, VOLS 1-8, 2007, : 2637 - +
  • [9] Variable Speed Control of DFIG-Wind Turbine under unbalanced grid voltage conditions
    Majdoub, Youssef
    Abbou, Ahmed
    Akherraz, Mohamed
    El Akhrif, Rachid
    Bakouri, Anass
    PROCEEDINGS OF 2015 3RD IEEE INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC'15), 2015, : 1224 - 1229
  • [10] Control and Protection of a DFIG-Based Wind Turbine under Unbalanced Grid Voltage Dips
    Zhou, Peng
    He, Yikang
    Sun, Dan
    Zhu, Jianguo
    2008 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, VOLS 1-5, 2008, : 2375 - +