Optimized Control for PMSG Wind Turbine Systems under Unbalanced and Distorted Grid Voltage Scenarios

被引:1
|
作者
Abo-Khalil, Ahmed G. [1 ,2 ]
Alobaid, Mohammad [3 ]
机构
[1] Univ Sharjah, Coll Engn, Sustainable & Renewable Energy Engn Dept, Sharjah, U Arab Emirates
[2] Assiut Univ, Coll Engn, Dept Elect Engn, Assiut 71515, Egypt
[3] Majmaah Univ, Coll Engn, Dept Mech & Ind Engn, Almajmaah 11952, Saudi Arabia
关键词
wind turbine; renewable energy; synchronous generator; total harmonic distortion; current harmonics; CONNECTED INVERTER; POWER; DFIG; SYNCHRONIZATION; DESIGN; SCHEME; FARMS;
D O I
10.3390/su15129552
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Wind energy is one of the fastest growing energies due to its feasible cost and environment friendly nature, where there is no emission of waste or greenhouse gases emission. Wind energy systems should be connected to the electric utility to avoid the effects of the intermittent nature of these sources. One of the main problems of the utility integration of wind turbines is the unbalanced voltage of the utility grid. Many efforts have been made to remedy the effects of the unbalanced grid voltage connected with the electric utility. This research points out the need for more accurate and robust controllers, such as those mentioned in this paper. A novel combination strategy is presented in this paper to overcome the inherent imbalance in the electric utility voltages when used in combination with a permanent magnet synchronous generator (PMSG). This novel technique is designed to adapt the positive sequence of the dq-axis of the output current from the PMSG to extract the maximum power available from a wind turbine. Meanwhile, the negative sequence component is used to improve the quality of the output current from a wind turbine. A current controller is introduced in the grid side converter to compensate for the effects of the 2nd and 6th components of the output currents. Using these controllers reduces all dominant components in the output currents from wind turbines and permits a robust tracker for the maximum power available. A detailed simulation and experimental studies are introduced in this paper to show the controller operation under different operating conditions. The simulation and experimental results from the novel proposed strategy show its superiority in fully remedying the effect of unbalanced grid voltages.
引用
收藏
页数:21
相关论文
共 50 条
  • [41] Control of a doubly fed induction wind generator under unbalanced grid voltage conditions
    Brekken, Ted K. A.
    Mohan, Ned
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) : 129 - 135
  • [42] A Novel Current Control Scheme of Grid Converters for Small PMSG Wind Turbines under Grid Voltage Distortion
    Thanh Hai Nguyen
    Lee, Dong-Choon
    2012 IEEE POWER ELECTRONICS AND MACHINES IN WIND APPLICATIONS (PEMWA), 2012,
  • [43] Control of a cascaded STATCOM with battery energy storage system under unbalanced and distorted grid voltage conditions
    Mao, Sumin
    Chen, Qiang
    Li, Rui
    Cai, Xu
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2017, 9 (04)
  • [44] Control Strategy for Dynamic Voltage Restorer Under Distorted and Unbalanced Voltage Conditions
    Zhang, Sen
    Zhao, Zhihong
    Zhao, Jianfeng
    Jin, Long
    Wang, Hong
    Sun, Haixiang
    Liu, Kangli
    Yang, Bin
    2019 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2019, : 411 - 416
  • [45] Improved control strategies for a DFIG-based wind-power generation system with SGSC under unbalanced and distorted grid voltage conditions
    Yao, Jun
    Yu, Mengting
    Hu, Weihao
    Chen, Zhe
    Zhou, Te
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 77 : 185 - 196
  • [46] Synchronization signal detection of fundamental voltage under unbalanced and harmonic distorted grid voltage conditions
    Zhou, Peng
    He, Yikang
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2010, 31 (01): : 78 - 84
  • [47] Adaptive Sliding Mode Control for PMSG Wind Turbine Systems
    Lee, Sung-Won
    Chun, Kwan-Ho
    ENERGIES, 2019, 12 (04)
  • [48] Combined Vector Control and Direct Power Control Methods for DFIG under Normal and Unbalanced and Distorted Grid Voltage Conditions
    Zarei, Mohammad Ebrahim
    Asaei, Behzad
    4TH ANNUAL INTERNATIONAL POWER ELECTRONICS, DRIVE SYSTEMS & TECHNOLOGIES CONFERENCE (PEDSTC 2013), 2013, : 107 - 112
  • [49] Dynamic modeling and control of a wind turbine with MPPT control connected to the grid by using PMSG
    Youness, El Mourabit
    Othmane, Zamzoum
    Aziz, Derouich
    Abdelaziz, El Ghzizal
    2017 3RD INTERNATIONAL CONFERENCE ON ADVANCED TECHNOLOGIES FOR SIGNAL AND IMAGE PROCESSING (ATSIP), 2017, : 123 - 128
  • [50] Improved control of dynamic voltage restorer for compensation of unbalanced and harmonic-distorted grid voltage
    Zhang, Runtao
    Hu, Xuekai
    Meng, Liang
    Zhou, Wen
    Luo, Peng
    Li, Zifan
    ENERGY REPORTS, 2023, 9 : 1803 - 1811