Synchronization signal detection of fundamental voltage under unbalanced and harmonic distorted grid voltage conditions

被引:0
|
作者
Zhou, Peng [1 ]
He, Yikang [1 ]
机构
[1] College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
关键词
Electric power system control - Locks (fasteners) - Harmonic analysis - Signal detection;
D O I
暂无
中图分类号
学科分类号
摘要
This paper proposes a novel grid fundamental voltage detection scheme. By means of solving the linear equations that are gained by differentiating the sampled three-phase grid voltage, it is able to calculate the positive and negative sequence components of the fundamental voltage, and the integral and non-integral harmonics in the unbalanced and distorted grid voltage. Based on the fundamental separation method, an improved software phase locked loop (PLL), which is designed to compensate the phase angle jump of the grid voltage, is applied to track the phase angle of the positive sequence component in the fundamental wave rapidly. Simulation and experimental results prove that the proposed algorithm has the characteristic of fast dynamic response and high precision, which provides a reliable basis for the control of various power electronic devices under grid faults.
引用
收藏
页码:78 / 84
相关论文
共 50 条
  • [1] Synchronizing signal detection of fundamental voltage under unbalanced and/or distorted grid voltage conditions
    Zhang, W. (weizhang@zju.edu.cn), 1600, Automation of Electric Power Systems Press (36):
  • [2] A SPLL Technique under Unbalanced and Seriously Distorted Grid Voltage Conditions
    Dang, Cun-lu
    Zhao, Xiao-gang
    26TH CHINESE CONTROL AND DECISION CONFERENCE (2014 CCDC), 2014, : 4523 - 4528
  • [3] Grid-tied converter operated under unbalanced and distorted grid voltage conditions
    Galecki, A.
    Michalczuk, M.
    Kaszewski, A.
    Ufnalski, B.
    Grzesiak, L. M.
    BULLETIN OF THE POLISH ACADEMY OF SCIENCES-TECHNICAL SCIENCES, 2020, 68 (02) : 389 - 398
  • [4] Sag Detection Algorithm for Dynamic Voltage Restorer used in Wind F arms under Unbalanced and Distorted Grid Voltage Conditions
    Zhou Sizhan
    Liu Jinjun
    Zhou Linyuan
    Zhu Yangque
    Yang Xu
    2013 IEEE ECCE ASIA DOWNUNDER (ECCE ASIA), 2013, : 601 - 606
  • [5] Grid synchronization PLL robust to frequency variation, unbalanced and distorted voltage
    Lee, Sanghoey
    Lee, Jeong-Hoon
    Cha, Hanju
    2011 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2011, : 1150 - 1155
  • [6] Enhanced Controllers of DFIG with Unbalanced and Distorted Grid Voltage Conditions
    Ramkumar, A.
    Durairaj, S.
    Dhivya, K.
    POWER ELECTRONICS AND RENEWABLE ENERGY SYSTEMS, 2015, 326 : 313 - 319
  • [7] Improved control of dynamic voltage restorer for compensation of unbalanced and harmonic-distorted grid voltage
    Zhang, Runtao
    Hu, Xuekai
    Meng, Liang
    Zhou, Wen
    Luo, Peng
    Li, Zifan
    ENERGY REPORTS, 2023, 9 : 1803 - 1811
  • [8] Improved control of dynamic voltage restorer for compensation of unbalanced and harmonic-distorted grid voltage
    Zhang, Runtao
    Hu, Xuekai
    Meng, Liang
    Zhou, Wen
    Luo, Peng
    Li, Zifan
    ENERGY REPORTS, 2023, 9 : 1803 - 1811
  • [9] Integrated Modeling and Enhanced Control of DFIG Under Unbalanced and Distorted Grid Voltage Conditions
    Xu, Hailiang
    Hu, Jiabing
    He, Yikang
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (03) : 725 - 736
  • [10] Dynamic Modeling and Improved Control of DFIG under Unbalanced and Distorted Grid Voltage Conditions
    Xu, Hailiang
    Hu, Jiabing
    Nian, Heng
    He, Yikang
    2012 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2012, : 1579 - 1584