Test-retest reliability of the unsupported upper-limb exercise test (UULEX) and 6-min peg board ring test (6PBRT) in healthy adult individuals

被引:22
|
作者
Lima, Vanessa Pereira [1 ]
Velloso, Marcelo [2 ]
Almeida, Fabiana Damasceno [2 ]
Carmona, Bianca [2 ]
Ribeiro-Samora, Giane Amorim [2 ]
Janaudis-Ferreira, Tania [3 ]
机构
[1] Univ Fed Vales Jequitinhonha & Mucuri Ufvjm, Dept Phys Therapy, Diamantina, MG, Brazil
[2] Univ Fed Minas Gerais Ufmg, Dept Phys Therapy, Belo Horizonte, MG, Brazil
[3] McGill Univ, Sch Phys & Occupat Therapy, Montreal, PQ H3A 0G4, Canada
关键词
Upper extremity; exercise; reliability; endurance; COPD and exercise tolerance; OBSTRUCTIVE PULMONARY-DISEASE; BETWEEN-DAY RELIABILITY; ARM; COPD; HYPERINFLATION; GUIDELINES; AGREEMENT;
D O I
10.1080/09593985.2018.1425786
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: The unsupported upper-limb exercise (UULEX) and 6-min peg board ring tests (6PBRTs) have been developed to measure peak unsupported arm exercise capacity and arm endurance, respectively, in individuals with chronic obstructive pulmonary disease. These tests are valid and reproducible in this population; however, the reproducibility of healthy adults is currently unknown. Objective: To determine the within-day test-retest reliability of the UULEX and 6PBRT in healthy adults. Method: The study included 41 healthy adults, aged 38.3 +/- 17.9years old, who performed both tests, twice each on the same day, with a 30-min rest in between. Before and immediately after the tests, blood pressure (BP), heart rate (HR), perception of exertion, and arm fatigue were measured. Time to perform the test and number of rings moved were recorded for the UULEX and 6PBRT, respectively. Results: The UULEX was reproducible on Bland-Altman analysis with lower and upper limits of agreement: 2.40 and -2.49min, respectively (bias=-0.05; p=0.817) and intraclass correlation coefficient (ICC)=0.85 (p<0.0001) for time in minutes for the first and second tests. The 6PBRT was not reproducible on Bland-Altman analysis with lower and upper limits of agreement of 31.64 and -114.54 (bias=-41.45; p<0.0001) and ICC=0.91 (p<0.0001) for the number of rings moved. Conclusion: UULEX is a reliable test in healthy adults. Only one test is adequate when measuring peak unsupported arm exercise capacity using the UULEX in healthy adults, while more than two tests may be needed to measure arm endurance using the 6PBRT.
引用
收藏
页码:806 / 812
页数:7
相关论文
共 37 条
  • [31] Test-retest reliability of auditory ERP components in healthy 6-year-old children
    Räikkönen, K
    Birkás, E
    Horváth, J
    Gervai, J
    Winkler, I
    NEUROREPORT, 2003, 14 (16) : 2121 - 2125
  • [32] Measurement properties of the 6-min walk test in individuals with exercise-induced pulmonary arterial hypertension
    Fowler, R. M.
    Jenkins, S. C.
    Maiorana, A. J.
    Gain, K. R.
    O'Driscoll, G.
    Gabbay, E.
    INTERNAL MEDICINE JOURNAL, 2011, 41 (09) : 679 - 687
  • [33] Test-retest reliability, validity, and sensitivity of the Chedoke Arm and Hand Activity Inventory: A new measure of upper-limb function for survivors of stroke
    Barreca, SR
    Stratford, PW
    Lambert, CL
    Masters, LM
    Streiner, DL
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2005, 86 (08): : 1616 - 1622
  • [34] The use of the 6-min walk test as a proxy for the assessment of energy expenditure during gait in individuals with lower-limb amputation
    Kark, Lauren
    McIntosh, Andrew S.
    Simmons, Anne
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2011, 34 (03) : 227 - 234
  • [35] Test-retest reliability and minimal detectable change of 9-Hole Peg Test, Box and Block test, Hand Grip Strength test and Manual Ability Measure-36 in moderate-to-severe upper limb impaired PwMS
    Grange, E.
    Rolla, M.
    Zidaric, M.
    Di, Giovanni R.
    Solaro, C.
    MULTIPLE SCLEROSIS JOURNAL, 2023, 29 : 42 - 43
  • [36] Determinants of the 6-minute pegboard and ring test as an unsupported upper-extremity exercise capacity measure in older adults with chronic obstructive pulmonary disease
    Ismail Ozsoy
    Buse Ozcan Kahraman
    Gulsah Ozsoy
    Nursen Ilcin
    Turhan Kahraman
    Serap Acar
    Nil Tekin
    Sema Savci
    European Geriatric Medicine, 2018, 9 : 863 - 870
  • [37] Determinants of the 6-minute pegboard and ring test as an unsupported upper-extremity exercise capacity measure in older adults with chronic obstructive pulmonary disease
    Ozsoy, Ismail
    Kahraman, Buse Ozcan
    Ozsoy, Gulsah
    Ilcin, Nursen
    Kahraman, Turhan
    Acar, Serap
    Tekin, Nil
    Savci, Sema
    EUROPEAN GERIATRIC MEDICINE, 2018, 9 (06) : 863 - 870