摘要
The purpose of this study was to determine whether steady-state free precession (SSFP) could improve accuracy of geometric models for evaluation of left ventricular (LV)function in comparison to turbo gradient echo (TGrE) and thereby reduce the acquisition and post-processing times, which are commonly long by use of the Simpson's Rule. In 25 subjects, cine loops of the complete heart in short and horizontal long-axis planes were acquired using TGrE (TR/TE/flip = 5.0/1.9/25) compared with SSFP (TR/TE/flip = 3.2/1.2/60). LV volumes and EF were measured with various geometric models for TGrE and SSFP. With three-dimensional data, the LV volumes were higher and the resulting EF lower for SSFP in contrast to TGrE (51 +/- 15% vs. 57 +/- 15%, p < 0.001). With SSFP, various geometric models yielded good to excellent correlations for LV volumes and LVEF compared to volumetric data (r = 0.94 - 0.98, mean relative difference 7.0-11.4%). In contrast, correlations were low using biplane or single-plane ellipsoid models in TGrE (r = 0.71 - 0.75, mean relative difference 15.9-30.2%). A new combined geometric model, taking all three dimensions into account, yielded the highest accuracy for SSFP in comparison to volumetric data (r = 0.99, mean relative difference 4.7%). Geometric models for assessment of LV volumes and EF yield higher accuracy and reproducibility by use of the SSFP sequence than by standard TGrE. This may increase clinical utility of magnetic resonance by shorter acquisition and processing times.
引用
收藏
页码:327 / 339
页数:13
相关论文
共 50 条
  • [41] IMPROVED ACCURACY OF LEFT-VENTRICULAR EJECTION FRACTION DETERMINED BY 2-DIMENSIONAL ECHOCARDIOGRAPHY
    GORGE, G
    WITTLICH, N
    BRENNEKE, R
    CIRCULATION, 1990, 82 (04) : 720 - 720
  • [42] Improved dark blood imaging of the heart using radial balanced steady-state free precession
    Robert R. Edelman
    Marcos Botelho
    Amit Pursnani
    Shivraman Giri
    Ioannis Koktzoglou
    Journal of Cardiovascular Magnetic Resonance, 18
  • [43] Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences
    Alfakih, K
    Plein, S
    Thiele, H
    Jones, T
    Ridgway, JP
    Sivananthan, MU
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) : 323 - 329
  • [44] EFFECT OF STEADY-STATE INCREASES IN SYSTEMIC ARTERIAL PRESSURE ON DURATION OF LEFT VENTRICULAR EJECTION TIME
    SHAVER, JA
    KROETZ, FW
    LEONARD, JJ
    PALEY, HW
    JOURNAL OF CLINICAL INVESTIGATION, 1968, 47 (01): : 217 - &
  • [45] Cardiovascular magnetic resonance evaluation of left ventricular peak filling rate using steady-state free precession and phase contrast sequences
    Komi, Shotaro
    Inoue, Yusuke
    Hata, Hirofumi
    Nakajima, Ai
    Miyatake, Hiroki
    SPRINGERPLUS, 2016, 5
  • [46] RADIONUCLIDE MEASUREMENTS OF EJECTION FRACTION AND LEFT-VENTRICULAR VOLUME CURVE - METHOD FOR INCREASING ACCURACY OF PROCEDURE
    PAVEL, DG
    BYROM, E
    BIANCO, JA
    ZIMMER, AM
    INVESTIGATIVE RADIOLOGY, 1977, 12 (05) : 399 - 399
  • [47] Unbiased signal equation for quantitative magnetization transfer mapping in balanced steady-state free precession MRI
    Bayer, Fritz M.
    Bock, Michael
    Jezzard, Peter
    Smith, Alex K.
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (01) : 446 - 456
  • [48] Improved cerebrospinal fluid flow measurements using phase contrast balanced steady-state free precession
    McCormack, Erin J.
    Egnor, Michael R.
    Wagshul, Mark E.
    MAGNETIC RESONANCE IMAGING, 2007, 25 (02) : 172 - 182
  • [49] VALIDATION OF REGIONAL EJECTION FRACTION - QUANTITATIVE RADIONUCLIDE ASSESSMENT OF REGIONAL LEFT-VENTRICULAR FUNCTION
    UREN, R
    MADDOX, DE
    PARKER, JA
    IDOINE, J
    COHN, PF
    HOLMAN, BL
    CIRCULATION, 1977, 56 (04) : 61 - 61
  • [50] Left ventricular to left arial volume ratio in the assessment of filling pressure in patients with dyspnoea and preserved ejection fraction
    Palka, Przemyslaw
    Hilling-Smith, Roland
    Swann, Rohan
    Allwood, Sean
    Moore, Alexander
    Bian, Chris
    Lange, Aleksandra
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11