Improved accuracy of quantitative assessment of left ventricular volume and ejection fraction by geometric models with steady-state free precession

被引:89
|
作者
Thiele, H
Paetsch, I
Schnackenburg, B
Bornstedt, A
Grebe, O
Wellnhofer, E
Schuler, G
Fleck, E
Nagel, E
机构
[1] Humboldt Univ, German Heart Inst, Clin Internal Med Cardiol, D-13353 Berlin, Germany
[2] Univ Leipzig, Ctr Heart, Clin Internal Med Cardiol, Leipzig, Germany
[3] Philips Med Syst, Hamburg, Germany
[4] Univ Ulm, Clin Internal Med 2, D-89069 Ulm, Germany
关键词
magnetic resonance; steady-state free precession; left ventricular function; left ventricular volumes; image quality;
D O I
10.1081/JCMR-120013298
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to determine whether steady-state free precession (SSFP) could improve accuracy of geometric models for evaluation of left ventricular (LV)function in comparison to turbo gradient echo (TGrE) and thereby reduce the acquisition and post-processing times, which are commonly long by use of the Simpson's Rule. In 25 subjects, cine loops of the complete heart in short and horizontal long-axis planes were acquired using TGrE (TR/TE/flip = 5.0/1.9/25) compared with SSFP (TR/TE/flip = 3.2/1.2/60). LV volumes and EF were measured with various geometric models for TGrE and SSFP. With three-dimensional data, the LV volumes were higher and the resulting EF lower for SSFP in contrast to TGrE (51 +/- 15% vs. 57 +/- 15%, p < 0.001). With SSFP, various geometric models yielded good to excellent correlations for LV volumes and LVEF compared to volumetric data (r = 0.94 - 0.98, mean relative difference 7.0-11.4%). In contrast, correlations were low using biplane or single-plane ellipsoid models in TGrE (r = 0.71 - 0.75, mean relative difference 15.9-30.2%). A new combined geometric model, taking all three dimensions into account, yielded the highest accuracy for SSFP in comparison to volumetric data (r = 0.99, mean relative difference 4.7%). Geometric models for assessment of LV volumes and EF yield higher accuracy and reproducibility by use of the SSFP sequence than by standard TGrE. This may increase clinical utility of magnetic resonance by shorter acquisition and processing times.
引用
收藏
页码:327 / 339
页数:13
相关论文
共 50 条
  • [21] Assessment of left ventricular ejection fraction measured by quantitative gated SPECT
    Abe, K
    Hirakawa, K
    Yonenaga, T
    Kobayashi, S
    Nishimura, M
    Ayabe, Z
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2006, 22 (02): : 223 - 230
  • [22] Quantitative analysis using steady-state free precession nuclear magnetic resonance
    Azeredo, RBD
    Colnago, LA
    Engelsberg, M
    ANALYTICAL CHEMISTRY, 2000, 72 (11) : 2401 - 2405
  • [23] Accuracy and reproducibility of geometric models for assessment of left ventricular ejection faction using cardiovascular magnetic resonance
    Peter Jordan
    Christopher A Miller
    Tom Newton
    Matthias Schmitt
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [24] Cardiac magnetic resonance imaging left ventricular stroke volume assessment accuracy comparison between short axis steady state free precession and flow velocity encoding gradients
    Troupis, C. J.
    Ford, C.
    Moir, S. W.
    Troupis, J. M.
    EUROPEAN JOURNAL OF HEART FAILURE, 2024, 26 : 199 - 200
  • [25] Left Ventricular Scar Detection in Hypertrophic Cardiomyopathy: A Radiomic Analysis of Steady-state Free Precession Cine Cardiac MRI
    Mancio, Jennifer
    Pashakhanloo, Farhad
    El-Rewaidy, Hossam
    Rowen, Ethan
    Manning, Warren J.
    Maron, Martin S.
    Nezafat, Reza
    CIRCULATION, 2019, 140
  • [26] Quantitative assessment of left ventricular volume and ejection fraction using two-dimensional speckle tracking echocardiography
    Nishikage, Tomoko
    Nakai, Hiromi
    Mor-Avi, Victor
    Lang, Roberto M.
    Salgo, Ivan S.
    Settlemier, Scott H.
    Husson, Stephane
    Takeuchi, Masaaki
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (01): : 82 - 88
  • [27] Normal left ventricular volumes and ejection fraction: assessment with quantitative digital cardioangiography
    Christiane Masquet
    Michel S. Slama
    Alain Dibie
    Florence H. Sheehan
    Jean Liénard
    The International Journal of Cardiac Imaging, 1998, 14 : 27 - 36
  • [28] Normal left ventricular volumes and ejection fraction:: assessment with quantitative digital cardioangiography
    Masquet, C
    Slama, MS
    Dibie, A
    Sheehan, FH
    Liénard, J
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1998, 14 (01): : 27 - 36
  • [29] Interleaved, undersampled radial multiple-acquisition steady-state free precession for improved left atrial cine imaging
    Robb, Jaime S.
    Hu, Chenxi
    Peters, Dana C.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (05) : 1721 - 1729
  • [30] COMPARISON OF SCINTIGRAPHIC COUNT VOLUME AND GEOMETRIC METHODS FOR MEASURING LEFT-VENTRICULAR EJECTION FRACTION
    TWIEG, D
    NARDIZZI, LR
    PARKEY, R
    WILLERSON, J
    ANNALS OF BIOMEDICAL ENGINEERING, 1978, 6 (03) : 310 - 325