Three column intermittent simulated moving bed chromatography: 1. Process description and comparative assessment

被引:13
|
作者
Jermann, Simon [1 ]
Mazzotti, Marco [1 ]
机构
[1] ETH, Inst Proc Engn, CH-8092 Zurich, Switzerland
关键词
Simulated moving bed chromatography; I-SMB; 3C-ISMB; Three-zone SMB; Separation of enantiomers; ADSORPTION SEPARATION PROCESSES; TROGERS BASE ENANTIOMERS; PARTIAL FEED; COUNTERCURRENT; OPERATION; DESIGN;
D O I
10.1016/j.chroma.2014.07.101
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The three column intermittent simulated moving bed (3C-ISMB) process is a new type of multi-column chromatographic process for binary separations and can be regarded as a modification of the I-SMB process commercialized by Nippon Rensui Corporation. In contrast to conventional I-SMB, this enables the use of only three instead of four columns without compromising product purity and throughput. The novel mode of operation is characterized by intermittent feeding and product withdrawal as well as by partial recycling of the weakly retained component from section III to section I. Due to the smaller number of columns with respect to conventional I-SMB, higher internal flow rates can be applied without violating pressure drop constraints. Therefore, the application of 3C-ISMB allows for a higher throughput whilst using a smaller number of columns. As a result, we expect that the productivity given hi terms of throughput per unit time and unit volume of stationary phase can be significantly increased. In this contribution, we describe the new process concept in detail and analyze its cyclic steady state behavior through an extensive simulation study. The latter shows that 3C-ISMB can be easily designed by Triangle Theory even under highly non-linear conditions. The simple process design is an important advantage to other advanced SMB-like processes. Moreover, the simulation study-demonstrates the superior performance of 3C-ISMB, namely productivity increases by roughly 60% with respect to conventional I-SMB without significantly sacrificing solvent consumption. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:125 / 138
页数:14
相关论文
共 50 条
  • [41] Comparing the performance one-column process and four-zone simulated moving bed by computer simulation
    Kim, YS
    Lee, CH
    Wankat, PC
    Koo, YM
    BIOTECHNOLOGY AND BIOPROCESS ENGINEERING, 2004, 9 (05) : 362 - 368
  • [42] Enantioseparation of 1-phenyl-1-propanol by supercritical fluid-simulated moving bed chromatography
    Rajendran, A
    Peper, S
    Johannsen, M
    Mazzotti, M
    Morbidelli, M
    Brunner, G
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1092 (01) : 55 - 64
  • [43] Use of single-column models for efficient computation of the periodic state of a simulated moving-bed process
    Araujo, Joao M. M.
    Rodrigues, Rui. C. R.
    Mota, Jose P. B.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2006, 45 (15) : 5314 - 5325
  • [44] Model-based design of an intermittent simulated moving bed process for recovering lactic acid from ternary mixture
    Song, Mingkai
    Cui, Linlin
    Kuang, Han
    Zhou, Jingwei
    Yang, Pengpeng
    Zhuang, Wei
    Chen, Yong
    Liu, Dong
    Zhu, Chenjie
    Chen, Xiaochun
    Ying, Hanjie
    Wu, Jinglan
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1562 : 47 - 58
  • [45] Chiral separation and modeling of the three-chiral-center β-blocker drug nadolol by simulated moving bed chromatography
    Wang, X
    Ching, CB
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1035 (02) : 167 - 176
  • [46] Micro simulated moving bed chromatography-mass spectrometry as a continuous on-line process analytical tool
    Juliane Diehm
    Lennart Witting
    Frank Kirschhöfer
    Gerald Brenner-Weiß
    Matthias Franzreb
    Analytical and Bioanalytical Chemistry, 2024, 416 : 373 - 386
  • [47] Micro simulated moving bed chromatography-mass spectrometry as a continuous on-line process analytical tool
    Diehm, Juliane
    Witting, Lennart
    Kirschhoefer, Frank
    Brenner-Weiss, Gerald
    Franzreb, Matthias
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (02) : 373 - 386
  • [48] Chiral separation by two-column, semi-continuous, open-loop simulated moving-bed chromatography
    Araujo, Joao M. M.
    Rodrigues, Rui C. R.
    Eusebio, Mario F. J.
    Mota, Jose P. B.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (33) : 5407 - 5419
  • [49] Modeling the extra column volume of a micro simulated moving bed chromatography system: Introducing the equivalent radial flow rate distribution
    Diehm, Juliane
    Franzreb, Matthias
    JOURNAL OF CHROMATOGRAPHY A, 2025, 1740
  • [50] Separation of 1,1'-bi-2-naphthol enantiomers by continuous chromatography in simulated moving bed
    Pais, LS
    Loureiro, JM
    Rodrigues, AE
    CHEMICAL ENGINEERING SCIENCE, 1997, 52 (02) : 245 - 257