Chiral separation by two-column, semi-continuous, open-loop simulated moving-bed chromatography

被引:21
|
作者
Araujo, Joao M. M. [1 ]
Rodrigues, Rui C. R. [1 ]
Eusebio, Mario F. J. [1 ]
Mota, Jose P. B. [1 ]
机构
[1] Univ Nova Lisboa, Fac Ciencias & Tecnol, Dept Quim, Requimte CQFB, P-2829516 Caparica, Portugal
关键词
Simulated moving bed; Open-loop configuration; Two-column process; Chiral separation; PERFORMANCE LIQUID-CHROMATOGRAPHY; CYCLIC MODULATION; PERIODIC STATE; OPTIMAL-DESIGN; ELUTION ORDER; OPERATION; FEED; FLOW; OPTIMIZATION; ENANTIOMERS;
D O I
10.1016/j.chroma.2010.06.040
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A two-column version of a multicolumn, semi-continuous, open-loop chromatograph for chiral separation is presented and validated experimentally. The heart of the process is a flexible node design and cyclic flow-rate modulation that succeed at keeping the mass-transfer zone inside the system without resorting to any recycling technique. One advantage of this streamlined design is the simplicity of its physical realization: regardless of the number of columns, it only requires two pumps to supply feed and desorbent into the system, while the flow rates of liquid withdrawn from the system are controlled by material balance using simple two-way valves. A rigorous model-based optimization approach is employed in the optimal cycle design to generate a solution that is physically realizable in the experimental apparatus. The optimized scheme for two-column operation supplies fresh feed into the system where the composition of the circulating fluid is closest to that of the feedstock fluid, and recovers the purified products, extract and raffinate, alternately at the downstream end of the unit while desorbent is supplied into the upstream end of the system. The feasibility and effectiveness of the two-column process are verified experimentally on the separation of reboxetine racemate, a norepinephrine re-uptake inhibitor, under overloaded conditions. Our set-up employs an automated on-line enantiomeric analysis system, comprising an analytical HPLC set-up with two UV detectors to monitor the composition profile at the downstream end of one of the columns; this monitoring system does not use a polarimeter. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:5407 / 5419
页数:13
相关论文
共 50 条
  • [1] Two-column simulated moving-bed process for binary separation
    Rodrigues, Rui C. R.
    Canhoto, Tiago J. S. B.
    Araujo, Joao M. M.
    Mota, Jose P. B.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1180 (1-2) : 42 - 52
  • [2] DEXTRAN FRACTIONATION ON A SEMI-CONTINUOUS COUNTERCURRENT SIMULATED MOVING-BED CHROMATOGRAPH
    BARKER, PE
    VLACHOGIANNIS, G
    ALSOP, RM
    CHROMATOGRAPHIA, 1983, 17 (03) : 149 - 153
  • [3] Robust design of adenovirus purification by two-column, simulated moving-bed, size-exclusion chromatography
    Nestola, Piergiuseppe
    Silva, Ricardo J. S.
    Peixoto, Cristina
    Alves, Paula M.
    Carrondo, Manuel J. T.
    Mota, Jose P. B.
    JOURNAL OF BIOTECHNOLOGY, 2015, 213 : 109 - 119
  • [4] Applications of simulated moving-bed chromatography to the separation of the enantiomers of chiral drugs
    Francotte, ER
    Richert, P
    JOURNAL OF CHROMATOGRAPHY A, 1997, 769 (01) : 101 - 107
  • [5] Two-column relay simulated moving-bed process for gas-phase separations
    Ribeiro, Rui P. P. L.
    Esteves, Isabel A. A. C.
    Mota, Jose P. B.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2017, 182 : 19 - 28
  • [6] Separation of enantiomers through simulated moving-bed chromatography
    Kniep, H
    Mann, G
    Vogel, C
    Seidel-Morgenstern, A
    CHEMICAL ENGINEERING & TECHNOLOGY, 2000, 23 (10) : 853 - 857
  • [7] SIMULATED MOVING-BED CHROMATOGRAPHY FOR CONTINUOUS SEPARATION OF 2 COMPONENTS AND ITS APPLICATION TO BIOREACTORS
    ADACHI, S
    JOURNAL OF CHROMATOGRAPHY A, 1994, 658 (02) : 271 - 282
  • [8] Design of Fructooligosaccharide Separation Using Simulated Moving-Bed Chromatography
    Vankova, Katarina
    Polakovic, Milan
    CHEMICAL ENGINEERING & TECHNOLOGY, 2012, 35 (01) : 161 - 168
  • [9] DYNAMIC SIMULATION OF CONTINUOUS SIMULATED MOVING-BED CHROMATOGRAPHY PROCESS
    SCHMIDTTRAUB, H
    STRUBE, J
    PAUL, HI
    MICHEL, S
    CHEMIE INGENIEUR TECHNIK, 1995, 67 (03) : 323 - 326
  • [10] Streamlined, two-column, simulated countercurrent chromatography for binary separation
    Rodrigues, Rui C. R.
    Silva, Ricardo J. S.
    Mota, Jose P. B.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (20) : 3382 - 3391