Batch-type detection cell using a peroxyoxalate chemiluminescence system for capillary electrophoresis

被引:19
|
作者
Tsukagoshi, K [1 ]
Otsuka, M [1 ]
Hashimoto, M [1 ]
Nakajima, R [1 ]
Kondo, K [1 ]
机构
[1] Doshisha Univ, Fac Engn, Dept Chem Engn & Mat Sci, Kyoto 6100321, Japan
关键词
capillary electrophoresis; chemiluminescence; peroxyoxalate; optical fiber; batch-type; alpha-amino acid;
D O I
10.2116/analsci.15.1257
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A batch-type chemiluminescence detection cell using a peroxyoxalate system was easily combined with capillary electrophoresis equipment; the device was operated without any tedious procedures. Peroxyoxalate reagents and hydrogen peroxide were examined in detail concerning their usage and concentration with the cell. Fluorescence-labeled alpha-amino acids showed the detection limits of 10 - 100 nM order (S/N=3), which were approximately 2 or 3 orders of magnitude lower than those obtained with the absorbance. A mixture sample of the labeled alpha-amino acids was successfully separated and detected.
引用
收藏
页码:1257 / 1260
页数:4
相关论文
共 50 条
  • [21] Chemiluminescence detection in capillary electrophoresis
    Campana, AMG
    Baeyens, WRG
    Zhao, YN
    ANALYTICAL CHEMISTRY, 1997, 69 (03) : A83 - A88
  • [22] CHEMILUMINESCENCE DETECTION IN CAPILLARY ELECTROPHORESIS
    COLON, LA
    DADOO, R
    ZARE, RN
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 203 : 50 - ANYL
  • [23] Simple and convenient cell for chemiluminescence detection in capillary electrophoresis
    Dept. of Chem. Eng. and Mat. Science, Faculty of Engineering, Doshisha University, Kyotanabe, Kyoto 610-0321, Japan
    Anal. Sci., 11 (1047-1048):
  • [24] Simple and convenient cell for chemiluminescence detection in capillary electrophoresis
    Tsukagoshi, K
    Nakamura, T
    Hashimoto, M
    Nakajima, R
    ANALYTICAL SCIENCES, 1999, 15 (11) : 1047 - 1048
  • [25] Simple and Convenient Cell for Chemiluminescence Detection in Capillary Electrophoresis
    Kazuhiko Tsukagoshi
    Takeshi Nakamura
    Masahiko Hashimoto
    Riichiro Nakajima
    Analytical Sciences, 1999, 15 : 1047 - 1048
  • [26] Miniaturization of batch- and flow-type chemiluminescence detectors in capillary electrophoresis
    Tsukagoshi, K
    Obata, Y
    Nakajima, R
    JOURNAL OF CHROMATOGRAPHY A, 2002, 971 (1-2) : 255 - 260
  • [27] Improvement of a capillary electrophoresis-chemiluminescence detection system for using a polyacrylamide-coated capillary
    Tsukagoshi, K
    Kimura, T
    Fuji, T
    Nakajima, R
    Arai, A
    ANALYTICAL SCIENCES, 2001, 17 (02) : 345 - 347
  • [28] Direct detection of biomolecules in a capillary electrophoresis-chemiluminescence detection system
    Tsukagoshi, K
    Nakahama, K
    Nakajima, R
    ANALYTICAL CHEMISTRY, 2004, 76 (15) : 4410 - 4415
  • [29] Post-column ultra-fast co-catalyzed peroxyoxalate chemiluminescence detection in capillary electrophoresis and capillary electrochromatography
    Carr, A
    Dickson, J
    Dickson, M
    Milofsky, R
    CHROMATOGRAPHIA, 2002, 55 (11-12) : 687 - 692
  • [30] Post-column ultra-fast co-catalyzed peroxyoxalate chemiluminescence detection in capillary electrophoresis and capillary electrochromatography
    A. Carr
    J. Dickson
    M. Dickson
    R. Milofsky
    Chromatographia, 2002, 55 : 687 - 692