Investigation of high-throughput ultrafiltration for the determination of an unbound compound in human plasma using liquid chromatography and tandem mass spectrometry with electrospray ionization

被引:33
|
作者
Zhang, Jin [1 ]
Musson, Donald G. [1 ]
机构
[1] Merck Res Labs, Dept Drug Metab, West Point, PA 19486 USA
关键词
unbound drug; ultrafiltration; Ultracel-PPB 96-well plate; Packard liquid handling system; human plasma; LC-MS/MS;
D O I
10.1016/j.jchromb.2006.05.042
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-throughput ultrafiltration method with a direct injection assay has been developed to determine unbound concentrations of a high-protein binding compound, an UA bone integrin antagonist (I), in human plasma for a clinical pharmacokinetic study. The 96-well MultiScreeno filter plate with Ultracel-PPB membrane was evaluated for the separation of unbound from protein-bound compound I by ultrafiltration. The sample preparation was automated using a Packard MultiPROBE II EX liquid handling system to transfer the plasma samples to the 96-well PPB plate for centrifugation and to prepare ultrafiltrate samples for analysis. Using on-line extraction with a column- switching setup for sample clean-up and separation, the ultrafiltrate samples were directly injected onto a reversed-phase HPLC system and analyzed using a mass spectrometer inter-faced with an electrospray ionization (ESI) source in the positive ionization mode (LC/ESI-MS/MS). The performance of the ultrafiltration using UltracelPPB 96-well plate for unbound I analysis was evaluated and optimized with respect to sample volume, centrifugation temperature, speed and time, and the relationship of the well positions of the PPB plate versus filtrate volumes and concentrations. The assay intraday accuracy and precision were between 93.9 and 104.8 and < 7.3% (CV), respectively. The linear range of the calibration curve for the assay was 0. 1-500 ng/mL on a Finnigan TSQ Quantum LC/ESI-MS/MS system. Evaluation and validation of the unbound plasma assay demonstrated it to be rapid, sensitive and reproducible. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:47 / 56
页数:10
相关论文
共 50 条
  • [41] Quantitation of tadalafil in human plasma by liquid chromatography-tandem mass spectrometry with electrospray ionization
    Ramakrishna, NVS
    Vishwottam, KN
    Puran, S
    Koteshwara, M
    Manoj, S
    Santosh, M
    Chidambara, J
    Wishu, S
    Sumatha, B
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (02): : 243 - 249
  • [42] Determination of tetrabromobisphenol A in human serum by liquid chromatography-electrospray ionization tandem mass spectrometry
    Hayama, T
    Yoshida, H
    Onimaru, S
    Yonekura, S
    Kuroki, H
    Todoroki, K
    Nohta, H
    Yamaguchi, M
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (01): : 131 - 136
  • [43] Determination of parabens in human urine by liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Lu, Shaoyou
    Gong, Shihan
    Ma, Shengtao
    Zeng, Xiangying
    Yu, Zhiqiang
    Sheng, Guoying
    Fu, Jiamo
    ANALYTICAL METHODS, 2014, 6 (15) : 5566 - 5572
  • [44] Quantification of Paroxetine in Human Plasma by Liquid Chromatography Coupled with Electrospray Ionization Tandem Mass Spectrometry
    Shah, Hiten J.
    Kundlik, Mohan L.
    Kakad, Abhijit
    Patel, Nitesh K.
    Pandya, Ankit
    Khatri, Vanita
    Prajapati, Shivkumat
    Subbaiah, Gunta
    Patel, Chhagan N.
    JOURNAL OF AOAC INTERNATIONAL, 2010, 93 (01) : 141 - 149
  • [45] Determination of isotretinoin in human plasma by high performance liquid chromatography-electrospray ionization mass spectrometry
    Wu, Lili
    Wu, Jingjing
    Zhou, Ke
    Cheng, Fang
    Chen, Yun
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (02) : 324 - 329
  • [46] Determination of enalapril in human plasma by high performance liquid chromatography-electrospray ionization mass spectrometry
    Yoon, KH
    Kim, W
    Park, J
    Kim, HJ
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2004, 25 (06): : 878 - 880
  • [47] Quantification of zolpidem in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Bhatt, Jignesh
    Jangid, Arvind
    Shetty, Raghavendra
    Shah, Bhavin
    Kambli, Sandeep
    Subbaiah, Gunta
    Singh, Sadhana
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (08) : 736 - 742
  • [48] Determination of sertraline in human plasma by high performance liquid chromatography coupled with electrospray ionization mass spectrometry
    Su Mingming
    Nie Yuxiao
    Jia Wei
    Chen Minjun
    He Yujia
    Li Zhongdong
    Shi Xiaojin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (08) : 1145 - 1148
  • [49] High sensitivity high performance liquid chromatography electrospray tandem mass spectrometry determination of terfenadine in human plasma
    Lau, YY
    Anderson, PH
    Talaat, R
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1996, 19 (16) : 2669 - 2679
  • [50] Determination of unbound piperaquine in human plasma by ultra-high performance liquid chromatography tandem mass spectrometry
    Huang, Liusheng
    Sok, Vong
    Aslam-Mir, Usman
    Marzan, Florence
    Whalen, Meghan
    Rosenthal, Philip J.
    Aweeka, Francesca
    JOURNAL OF CHROMATOGRAPHY OPEN, 2022, 2