Investigation of high-throughput ultrafiltration for the determination of an unbound compound in human plasma using liquid chromatography and tandem mass spectrometry with electrospray ionization

被引:33
|
作者
Zhang, Jin [1 ]
Musson, Donald G. [1 ]
机构
[1] Merck Res Labs, Dept Drug Metab, West Point, PA 19486 USA
关键词
unbound drug; ultrafiltration; Ultracel-PPB 96-well plate; Packard liquid handling system; human plasma; LC-MS/MS;
D O I
10.1016/j.jchromb.2006.05.042
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-throughput ultrafiltration method with a direct injection assay has been developed to determine unbound concentrations of a high-protein binding compound, an UA bone integrin antagonist (I), in human plasma for a clinical pharmacokinetic study. The 96-well MultiScreeno filter plate with Ultracel-PPB membrane was evaluated for the separation of unbound from protein-bound compound I by ultrafiltration. The sample preparation was automated using a Packard MultiPROBE II EX liquid handling system to transfer the plasma samples to the 96-well PPB plate for centrifugation and to prepare ultrafiltrate samples for analysis. Using on-line extraction with a column- switching setup for sample clean-up and separation, the ultrafiltrate samples were directly injected onto a reversed-phase HPLC system and analyzed using a mass spectrometer inter-faced with an electrospray ionization (ESI) source in the positive ionization mode (LC/ESI-MS/MS). The performance of the ultrafiltration using UltracelPPB 96-well plate for unbound I analysis was evaluated and optimized with respect to sample volume, centrifugation temperature, speed and time, and the relationship of the well positions of the PPB plate versus filtrate volumes and concentrations. The assay intraday accuracy and precision were between 93.9 and 104.8 and < 7.3% (CV), respectively. The linear range of the calibration curve for the assay was 0. 1-500 ng/mL on a Finnigan TSQ Quantum LC/ESI-MS/MS system. Evaluation and validation of the unbound plasma assay demonstrated it to be rapid, sensitive and reproducible. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:47 / 56
页数:10
相关论文
共 50 条
  • [21] Determination of gatifloxacin in human plasma by liquid chromatography/electrospray tandem mass spectrometry
    Vishwanathan, K
    Bartlett, MG
    Stewart, JT
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (12) : 915 - 919
  • [22] Determination of procarbazine in human plasma by liquid chromatography with electrospray ionization mass spectrometry
    He, X
    Batchelor, TT
    Grossman, S
    Supko, JG
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 799 (02): : 281 - 291
  • [23] Determination of metolazone in human blood by liquid chromatography with electrospray ionization tandem mass spectrometry
    Wei, Guangli
    Xiao, Shuhua
    Liu, Changxiao
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 845 (01): : 169 - 173
  • [24] High-throughput quantification of soy isoflavones in human and rodent blood using liquid chromatography with electrospray mass spectrometry and tandem mass spectrometry detection
    Twaddle, NC
    Churchwell, MI
    Doerge, DR
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 777 (1-2): : 139 - 145
  • [25] Analysis of sphingolipids in extracted human plasma using liquid chromatography electrospray ionization tandem mass spectrometry
    Bui, Hai H.
    Leohr, Jennifer K.
    Kuo, Ming-Shang
    ANALYTICAL BIOCHEMISTRY, 2012, 423 (02) : 187 - 194
  • [26] Determination of total and unbound concentrations of lopinavir in plasma using liquid chromatography-tandem mass spectrometry and ultrafiltration methods
    Illamola, S. M.
    Labat, L.
    Benaboud, S.
    Tubiana, R.
    Warszawski, J.
    Treluyer, J. M.
    Hirt, D.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 965 : 216 - 223
  • [27] Determination of finasteride in human plasma by liquid chromatography–electrospray ionization tandem mass spectrometry with flow rate gradient
    Lihua Yuan
    Meijuan Ding
    Jing Ma
    Jinhui Xu
    Xiaoli Wu
    Jing Feng
    Fei Shen
    Xuemin Zhou
    European Journal of Drug Metabolism and Pharmacokinetics, 2011, 35 : 137 - 146
  • [28] Determination of lodenosine and its major metabolite in human plasma by liquid chromatography/electrospray ionization tandem mass spectrometry
    Roth, JS
    Wang, J
    Kelley, JA
    JOURNAL OF MASS SPECTROMETRY, 2000, 35 (11): : 1313 - 1319
  • [29] Determination of loratadine in human plasma by liquid chromatography electrospray ionization ion-trap tandem mass spectrometry
    Salem, II
    Idrees, J
    Al Tamimi, JI
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (01) : 141 - 151
  • [30] Determination of lovastatin in human plasma by ultra-performance liquid chromatography/electrospray ionization tandem mass spectrometry
    Wang, Dong
    Wang, Dongmei
    Qin, Feng
    Chen, Lingyun
    Li, Famei
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (05) : 511 - 518