Investigation of high-throughput ultrafiltration for the determination of an unbound compound in human plasma using liquid chromatography and tandem mass spectrometry with electrospray ionization

被引:33
|
作者
Zhang, Jin [1 ]
Musson, Donald G. [1 ]
机构
[1] Merck Res Labs, Dept Drug Metab, West Point, PA 19486 USA
关键词
unbound drug; ultrafiltration; Ultracel-PPB 96-well plate; Packard liquid handling system; human plasma; LC-MS/MS;
D O I
10.1016/j.jchromb.2006.05.042
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-throughput ultrafiltration method with a direct injection assay has been developed to determine unbound concentrations of a high-protein binding compound, an UA bone integrin antagonist (I), in human plasma for a clinical pharmacokinetic study. The 96-well MultiScreeno filter plate with Ultracel-PPB membrane was evaluated for the separation of unbound from protein-bound compound I by ultrafiltration. The sample preparation was automated using a Packard MultiPROBE II EX liquid handling system to transfer the plasma samples to the 96-well PPB plate for centrifugation and to prepare ultrafiltrate samples for analysis. Using on-line extraction with a column- switching setup for sample clean-up and separation, the ultrafiltrate samples were directly injected onto a reversed-phase HPLC system and analyzed using a mass spectrometer inter-faced with an electrospray ionization (ESI) source in the positive ionization mode (LC/ESI-MS/MS). The performance of the ultrafiltration using UltracelPPB 96-well plate for unbound I analysis was evaluated and optimized with respect to sample volume, centrifugation temperature, speed and time, and the relationship of the well positions of the PPB plate versus filtrate volumes and concentrations. The assay intraday accuracy and precision were between 93.9 and 104.8 and < 7.3% (CV), respectively. The linear range of the calibration curve for the assay was 0. 1-500 ng/mL on a Finnigan TSQ Quantum LC/ESI-MS/MS system. Evaluation and validation of the unbound plasma assay demonstrated it to be rapid, sensitive and reproducible. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:47 / 56
页数:10
相关论文
共 50 条
  • [1] High-throughput determination of atrasentan in human plasma by high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Wang, PG
    Wei, J
    Chang, M
    El-Shourbagy, T
    BIOMEDICAL CHROMATOGRAPHY, 2005, 19 (09) : 663 - 670
  • [2] Determination of flomoxef in human plasma by liquid chromatography/electrospray ionization tandem mass spectrometry
    Kravtsova, Oxana Yu.
    Paramonov, Sergey A.
    Vasilevich, Natalya I.
    Kazyulkin, Denis N.
    Vlasova, Ekaterina
    Engsig, Michael
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (12) : 1609 - 1614
  • [3] Determination of moxifloxacin in human plasma by liquid chromatography electrospray ionization tandem mass spectrometry
    Vishwanathan, K
    Bartlett, MG
    Stewart, JT
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (04) : 961 - 968
  • [4] HIGH-THROUGHPUT DETERMINATION OF LINEZOLID IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Vlase, Laurian
    Muntean, Dana
    Cuciureanu, Magdalena
    Cuciureanu, Rodica
    Gocan, Simion
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (06) : 436 - 445
  • [5] HIGH-THROUGHPUT DETERMINATION OF LINEZOLID IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Vlase, Laurian
    Muntean, Dana
    Cuciureanu, Magdalena
    Cuciureanu, Rodica
    Gocan, Simion
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (08) : 591 - 600
  • [6] Quantitative determination of rosuvastatin in human plasma by liquid chromatography with electrospray ionization tandem mass spectrometry
    Xu, Dong-Hang
    Ruan, Zou-Rong
    Zhou, Quan
    Yuan, Hong
    Jiang, Bo
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (16) : 2369 - 2375
  • [7] Determination of bulleyaconitine A in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Weng, WY
    Xu, HN
    Huang, JM
    Wang, GQ
    Shen, T
    Zhang, JF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 816 (1-2): : 315 - 320
  • [8] Determination of glimepiride in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Salem, II
    Idrees, J
    Al Tamimi, JI
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 799 (01): : 103 - 109
  • [9] Determination of clarithromycin in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Jiang, Yao
    Wang, Jiang
    Li, Hao
    Wang, Yingwu
    Gu, Jingkai
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (04) : 1460 - 1464
  • [10] Determination and Quantification of Phenytoin in Human Plasma by Liquid Chromatography with Electrospray Ionization Tandem Mass Spectrometry
    Roy, S. M. N.
    Yetal, S. M.
    Vaidya, V. V.
    Joshi, S. S.
    E-JOURNAL OF CHEMISTRY, 2008, 5 (01) : 169 - 176