Validation of a smartphone-based Rinne test to detect an air-bone gap

被引:5
|
作者
Hibscher, Daniel [1 ]
Oron, Yahav [1 ]
Handzel, Ophir [1 ]
Warshavsky, Anton [1 ]
Horowitz, Gilad [1 ]
Ungar, Omer J. [1 ]
机构
[1] Tel Aviv Univ, Tel Aviv Sourasky Med Ctr, Sackler Sch Med, Dept Otolaryngol Head Neck & Maxillofacial Surg, 6 Weizmann St, IL-6423906 Tel Aviv, Israel
关键词
Hearing loss; Sudden sensorineural hearing loss; Rinne test; Conductive hearing loss; Tuning fork;
D O I
10.1007/s00405-021-06608-9
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective To validate a smartphone-based Rinne test employing the vibration application of mobile telephones. Study design Prospective controlled clinical study. Setting Tertiary referral medical center. Methods Twenty consecutive patients hospitalized in the otolaryngology department of a tertiary medical center due to unilateral hearing loss (HL study group), and 30 consecutive inpatients on the same ward who had no otological history (controls) were enrolled. Each participant underwent the traditional 512 Hz tuning fork-based Rinne test, as well as a smartphone-based Rinne test by means of a single uncovered smartphone with a vibration application. The test results were compared to those of formal audiometry. Results The overall agreement between the traditional Rinne test and the smartphone-based test was 98%. The Sensitivity was 85% for both tests, specificity was 90% and 93% for smartphone and tuning fork tests, respectively. The smartphone-based Rinne test could correctly discriminate between patients with an air-bone gap >= 25 dB at 512 Hz from patients with a lower or no air-bone gap at 512 Hz. The smartphone-based Rinne could not evaluate two patients with a moderately severe/severe sensorineural hearing loss due to their inability to detect the vibrations. Conclusion A smartphone-based Rinne test was validated for the detection of an air-bone gap >= 25 dB at 512 Hz in the clinical setting. The validity of patient-operated smartphone-based Rinne test awaits further study. Level of evidence 2B.
引用
收藏
页码:4767 / 4773
页数:7
相关论文
共 50 条
  • [31] Smartphone-based colorimetric detection of formaldehyde in the air
    Yang, Meng
    Ye, Jin
    Yu, Tao
    Song, Ying
    Qian, Hua
    Liu, Tianyi
    Chen, Yang
    Wang, Junqi
    Cao, Shi-jie
    Liu, Cong
    BUILDING SIMULATION, 2024, 17 (11) : 2007 - 2015
  • [32] The icompanion Finger Dexterity Test: validation study of a smartphone-based manual dexterity assessment
    Van Laethem, Delphine
    Denissen, Stijn
    Costers, Lars
    Descamps, Annabel
    Baijot, Johan
    Van Remoortel, Ann
    Van Merhaegen-Wieleman, Annick
    D'hooghe, Marie
    D'haeseleer, Miguel
    Smeets, Dirk
    Sima, Diana
    Van Schependom, Jeroen
    Nagels, Guy
    MULTIPLE SCLEROSIS JOURNAL, 2023, 29 : 190 - 191
  • [33] Validation of the New York University Langone Eye Test Application, a Smartphone-Based Visual Acuity Test
    Iskander, Mina
    Hu, Galen
    Sood, Shefali
    Heilenbach, Noah
    Sanchez, Victor
    Ogunsola, Titilola
    Chen, Dinah
    Elgin, Ceyhun
    Patel, Vipul
    Wronka, Andrew
    Al-Aswad, Lama A.
    OPHTHALMOLOGY SCIENCE, 2022, 2 (03):
  • [34] When an Air-Bone Gap is not a Sign of a Middle Ear Conductive Hearing Loss
    Sohmer, Haim
    Sichel, Jean-Yves
    Perez, Ronen
    Adelma, Cahtia
    EAR AND HEARING, 2009, 30 (01): : 147 - 148
  • [35] Dataset of Smartphone-Based Finger Tapping Test
    Lima, Ramon Costa
    Brito, Felipe Andre da Costa
    do Nascimento, Rodrigo Luz
    Martins, Sthephanie Nazare e Silva
    Pereira, Luis Carlos Monteiro
    Seabra, Jessica Portal
    Farias, Hugo Leonnardo Chaves
    da Silva, Laenna Morgana Cunha
    de Miranda, Victor Matheus Silva
    Belgamo, Anderson
    Cabral, Andre dos Santos
    Callegari, Bianca
    Silva, Anselmo de Athayde Costa e
    Crisp, Alex
    Alves, Candida Helena Lopes
    Lacerda, Eliza Maria da Costa Brito
    Souza, Givago Silva
    SCIENTIFIC DATA, 2024, 11 (01)
  • [36] A superior semicircular canal dehiscence-induced air-bone gap in chinchilla
    Songer, Jocelyn E.
    Rosowski, John J.
    HEARING RESEARCH, 2010, 269 (1-2) : 70 - 80
  • [37] MIDDLE-EAR EFFUSION - RELATIONSHIP OF TYMPANOMETRY AND AIR-BONE GAP TO VISCOSITY
    FORQUER, BD
    LINTHICUM, FH
    EAR AND HEARING, 1980, 1 (02): : 87 - 90
  • [38] Stapes and Stapes Revision Surgery: Preoperative Air-Bone Gap Is a Prognostic Marker
    Sharaf, Kariem
    Grueninger, Ivo
    Hilpert, Annalena
    Polterauer, Daniel
    Volgger, Veronika
    Manz, Kirsi
    Canis, Martin
    Hempel, John Martin
    Mueller, Joachim
    OTOLOGY & NEUROTOLOGY, 2021, 42 (07) : 985 - 993
  • [39] Smartphone-based Nonmydriatic Fundus Imaging to Detect Diabetic Retinopathy
    Bhardwaj, Mahesh Kumar
    Stratton, Samuel
    Roh, Shiyoung
    Luna, Jorge
    Cotran, Paul R.
    Ramsey, David J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [40] AIR-BONE GAP IN PATIENTS WITH X-LINKED STAPES GUSHER SYNDROME
    SNIK, AFM
    HOMBERGEN, GCJH
    MYLANUS, EAM
    CREMERS, CWRJ
    AMERICAN JOURNAL OF OTOLOGY, 1995, 16 (02): : 241 - 246