Validation of a smartphone-based Rinne test to detect an air-bone gap

被引:5
|
作者
Hibscher, Daniel [1 ]
Oron, Yahav [1 ]
Handzel, Ophir [1 ]
Warshavsky, Anton [1 ]
Horowitz, Gilad [1 ]
Ungar, Omer J. [1 ]
机构
[1] Tel Aviv Univ, Tel Aviv Sourasky Med Ctr, Sackler Sch Med, Dept Otolaryngol Head Neck & Maxillofacial Surg, 6 Weizmann St, IL-6423906 Tel Aviv, Israel
关键词
Hearing loss; Sudden sensorineural hearing loss; Rinne test; Conductive hearing loss; Tuning fork;
D O I
10.1007/s00405-021-06608-9
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective To validate a smartphone-based Rinne test employing the vibration application of mobile telephones. Study design Prospective controlled clinical study. Setting Tertiary referral medical center. Methods Twenty consecutive patients hospitalized in the otolaryngology department of a tertiary medical center due to unilateral hearing loss (HL study group), and 30 consecutive inpatients on the same ward who had no otological history (controls) were enrolled. Each participant underwent the traditional 512 Hz tuning fork-based Rinne test, as well as a smartphone-based Rinne test by means of a single uncovered smartphone with a vibration application. The test results were compared to those of formal audiometry. Results The overall agreement between the traditional Rinne test and the smartphone-based test was 98%. The Sensitivity was 85% for both tests, specificity was 90% and 93% for smartphone and tuning fork tests, respectively. The smartphone-based Rinne test could correctly discriminate between patients with an air-bone gap >= 25 dB at 512 Hz from patients with a lower or no air-bone gap at 512 Hz. The smartphone-based Rinne could not evaluate two patients with a moderately severe/severe sensorineural hearing loss due to their inability to detect the vibrations. Conclusion A smartphone-based Rinne test was validated for the detection of an air-bone gap >= 25 dB at 512 Hz in the clinical setting. The validity of patient-operated smartphone-based Rinne test awaits further study. Level of evidence 2B.
引用
收藏
页码:4767 / 4773
页数:7
相关论文
共 50 条
  • [1] Validation of a smartphone-based Rinne test to detect an air-bone gap
    Daniel Hibscher
    Yahav Oron
    Ophir Handzel
    Anton Warshavsky
    Gilad Horowitz
    Omer J. Ungar
    European Archives of Oto-Rhino-Laryngology, 2021, 278 : 4767 - 4773
  • [2] FALSE AIR-BONE GAP
    RUDMIN, F
    EAR AND HEARING, 1983, 4 (02): : 106 - 107
  • [3] FALSE AIR-BONE GAP
    不详
    EYE EAR NOSE AND THROAT MONTHLY, 1965, 44 (02): : 96 - &
  • [4] INTERTEST VARIABILITY AND AIR-BONE GAP
    STUDEBAKER, GA
    JOURNAL OF SPEECH AND HEARING DISORDERS, 1967, 32 (01): : 82 - 86
  • [5] IMPEDANCE TESTS AND AIR-BONE GAP
    JACOBS, R
    HERON, TG
    AUDIOLOGY, 1972, 11 : 83 - 84
  • [6] Development and Validation of a Smartphone-based Contrast Sensitivity Test
    Habtamu, Esmael
    Bastawrous, Andrew
    Bolster, Nigel M.
    Tadesse, Zerihun
    Callahan, E. Kelly
    Gashaw, Bizuayehu
    Macleod, David
    Burton, Matthew J.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2019, 8 (05):
  • [7] Can Myringoplasty Close the Air-Bone Gap?
    Pfammatter, Alain
    Novoa, Eva
    Linder, Thomas
    OTOLOGY & NEUROTOLOGY, 2013, 34 (04) : 705 - 710
  • [8] THE CANCELLATION METHOD FOR AN ACCURATE DETERMINATION OF AN AIR-BONE GAP
    KAPTEYN, TS
    SNEL, AM
    VIS, EC
    ARCHIVES OF OTO-RHINO-LARYNGOLOGY-ARCHIV FUR OHREN-NASEN-UND KEHLKOPFHEILKUNDE, 1980, 228 (03): : 199 - 204
  • [9] Aging and the 4-kHz Air-Bone Gap
    Nondahl, David M.
    Tweed, Ted S.
    Cruickshanks, Karen J.
    Wiley, Terry L.
    Dalton, Dayna S.
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2012, 55 (04): : 1128 - 1134
  • [10] Stapedoplasty in patients with small air-bone gap: why not?
    Salvinelli, F
    Casale, M
    Di Peco, V
    Greco, F
    Trivelli, M
    MEDICAL HYPOTHESES, 2003, 60 (04) : 535 - 537