Taper fretting behavior of PEEK artificial hip joint

被引:18
|
作者
Xu, Handong [1 ]
Zhang, Dekun [2 ]
Chen, Kai [2 ]
Zhang, Tao [1 ]
机构
[1] China Univ Min & Technol, Sch Mechatron Engn, Xuzhou 221116, Jiangsu, Peoples R China
[2] China Univ Min & Technol, Sch Mat Sci & Engn, Xuzhou 221116, Jiangsu, Peoples R China
关键词
PEEK; Ti6Al4V; Wear mechanism; Fretting behavior; FINITE-ELEMENT; WEAR; ALLOY; REPLACEMENTS; CORROSION; IMPLANTS; JUNCTION; DEBRIS;
D O I
10.1016/j.triboint.2019.04.027
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
To study the fretting tribological behavior of a PEEK hip prosthesis, Ti6Al4V was used as the stem taper material, PEEK was used as the head material, and CoCrMo was used as the contrast material for the PEEK. Fretting friction and wear experiments between the stem taper and head were carried out to demonstrate the feasibility of PEEK as a metal substitute. The results show that the wear values of the Ti6Al4V/PEEK and Ti6Al4V/CoCrMo pairs were all of a small order of magnitude. The Ti6Al4V/PEEK pairs had a better corrosion resistance than the Ti6Al4V/CoCrMo pairs. Meanwhile, the fretting characteristics and damage mechanism of the Ti6Al4V/PEEK pairs were obtained.
引用
收藏
页码:30 / 38
页数:9
相关论文
共 50 条
  • [21] Adaptive finite element simulation of fretting wear and fatigue in a taper junction of modular hip prosthesis
    Messellek, Ali Cherif
    Ouali, Mohand Ould
    Amrouche, Abdelwaheb
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 111
  • [22] Do Ceramic Femoral Heads Reduce Taper Fretting Corrosion in Hip Arthroplasty? A Retrieval Study
    Kurtz, Steven M.
    Kocagoez, Sevi B.
    Hanzlik, Josa A.
    Underwood, Richard J.
    Gilbert, Jeremy L.
    MacDonald, Daniel W.
    Lee, Gwo-Chin
    Mont, Michael A.
    Kraay, Matthew J.
    Klein, Gregg R.
    Parvizi, Javad
    Rimnac, Clare M.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (10) : 3270 - 3282
  • [23] A review on the finite element simulation of fretting wear and corrosion in the taper junction of hip replacement implants
    Feyzi, Mohsen
    Fallahnezhad, Khosro
    Taylor, Mark
    Hashemi, Reza
    COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 130
  • [24] Variability in stem taper surface topography affects the degree of corrosion and fretting in total hip arthroplasty
    Kilian Elia Stockhausen
    Christoph Riedel
    Alex Victoria Belinski
    Dorothea Rothe
    Thorsten Gehrke
    Felix Klebig
    Matthias Gebauer
    Michael Amling
    Mustafa Citak
    Björn Busse
    Scientific Reports, 11
  • [25] Variability in stem taper surface topography affects the degree of corrosion and fretting in total hip arthroplasty
    Stockhausen, Kilian Elia
    Riedel, Christoph
    Belinski, Alex Victoria
    Rothe, Dorothea
    Gehrke, Thorsten
    Klebig, Felix
    Gebauer, Matthias
    Amling, Michael
    Citak, Mustafa
    Busse, Bjorn
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [26] Compliant interfaces and fretting corrosion of modular taper junctions in total hip implants: The micromechanics of contact
    Smith, Stephanie M.
    Gilbert, Jeremy L.
    TRIBOLOGY INTERNATIONAL, 2020, 151
  • [27] Effect of fretting regimes on the fretting corrosion behavior of stainless steel in artificial crevices
    Liu, Heng
    Chen, Jiachen
    Tian, Xiangdong
    Wang, Zening
    Zhang, Yi
    Yan, Yu
    CORROSION SCIENCE, 2024, 231
  • [28] Evaluation of fretting corrosion fatigue in burnishing of Ti6Al4V component for artificial hip joint
    Rotella, Giovanna
    Cosco, Francesco
    Saffioti, Maria Rosaria
    Umbrello, Domenico
    CIRP ANNALS-MANUFACTURING TECHNOLOGY, 2023, 72 (01) : 509 - 512
  • [29] Fretting wear of PEEK against XLPE
    Xu, Handong
    Zhang, Dekun
    Chen, Kai
    Zhang, Tao
    MATERIALS RESEARCH EXPRESS, 2018, 5 (06):
  • [30] Optimization of Artificial Hip Joint Parameters
    Darwish, S. M.
    Al-Samhan, A. M.
    MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 2009, 40 (03) : 218 - 223