A review on the finite element simulation of fretting wear and corrosion in the taper junction of hip replacement implants

被引:29
|
作者
Feyzi, Mohsen [1 ]
Fallahnezhad, Khosro [1 ]
Taylor, Mark [1 ]
Hashemi, Reza [1 ]
机构
[1] Flinders Univ S Australia, Med Device Res Inst, Coll Sci & Engn, Tonsley, SA 5042, Australia
关键词
Taperosis; Fretting wear; Finite element analysis; Taper junction; Hip implants;
D O I
10.1016/j.compbiomed.2020.104196
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Taperosis/trunnionosis is a scientific term for describing tribocorrosion (fretting corrosion) at the head-neck taper junction of hip implants where two contacting surfaces are undergone oscillatory micromotions while being exposed to the body fluid. Detached ions and emitted debris, as a result of taperosis, migrate to the surrounding tissues and can cause inflammation, infection, and aseptic loosening with an ultimate possibility of implant failure. Improving the tribocorrosion performance of the head-neck junction in the light of minimising the surface damage and debris requires a better understanding of taperosis. Given its complexity associated with both the mechanical and electrochemical aspects, computational methods such as the finite element method have been recently employed for analysing fretting wear and corrosion in the taper junction. To date, there have been more efforts on the fretting wear simulation when compared with corrosion. This is because of the mechanical nature of fretting wear which is probably more straightforward for modelling. However, as a recent research advancement, corrosion has been a focus to be implemented in the finite element modelling of taper junctions. This paper aims to review finite element studies related to taperosis in the head-neck junction to provide a detailed understanding of the design parameters and their role in this failure mechanism. It also reviews and discusses the methodologies developed for simulating this complex process in the taper junction along with the simplifications, assumptions and findings reported in these studies. The current needs and future research opportunities and directions in this field are then identified and presented.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Adaptive finite element simulation of fretting wear and fatigue in a taper junction of modular hip prosthesis
    Messellek, Ali Cherif
    Ouali, Mohand Ould
    Amrouche, Abdelwaheb
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 111
  • [2] An adaptive finite element simulation of fretting wear damage at the head neck taper junction of total hip replacement: The role of taper angle mismatch
    Fallahnezhad, Khosro
    Oskouei, Reza H.
    Badnava, Hojjat
    Taylor, Mark
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 75 : 58 - 67
  • [3] An Overview of the Stability and Fretting Corrosion of Microgrooved Necks in the Taper Junction of Hip Implants
    Feyzi, Mohsen
    Fallahnezhad, Khosro
    Taylor, Mark
    Hashemi, Reza
    MATERIALS, 2022, 15 (23)
  • [4] FINITE ELEMENT APPROACH TO DESIGN OF MODULAR HIP IMPLANTS MINIMIZING FRETTING WEAR
    Mech, Dhruba Jyoti
    Chakraborty, Arindam
    Chowdhury, Amit Roy
    Datta, Pallab
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2022, 22 (07)
  • [5] A combined experimental and finite element approach to analyse the fretting mechanism of the head-stem taper junction in total hip replacement
    Bitter, Thom
    Khan, Imran
    Marriott, Tim
    Lovelady, Elaine
    Verdonschot, Nico
    Janssen, Dennis
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2017, 231 (09) : 862 - 870
  • [6] Finite element wear prediction using adaptive meshing at the modular taper interface of hip implants
    Bitter, Thom
    Khan, Imran
    Marriott, Tim
    Lovelady, Elaine
    Verdonschot, Nico
    Janssen, Dennis
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 77 : 616 - 623
  • [7] The effect of different assembly loads on taper junction fretting wear in total hip replacements
    English, Russell
    Ashkanfar, Ariyan
    Rothwell, Glynn
    TRIBOLOGY INTERNATIONAL, 2016, 95 : 199 - 210
  • [8] Influence of the taper on the fretting wear of the femoral stem-femoral head taper junction in total hip prosthesis
    Capitanu, Lucian
    Badita, Liliana-Laura
    Tiganesteanu, Constantin
    Florescu, Virgil
    INDUSTRIAL LUBRICATION AND TRIBOLOGY, 2022, 74 (04) : 385 - 391
  • [9] Finite element simulation and experimental validation of fretting wear
    McColl, IR
    Ding, J
    Leen, SB
    WEAR, 2004, 256 (11-12) : 1114 - 1127
  • [10] Protein-metal interactions due to fretting corrosion at the taper junction of hip implants: An in vitro investigation using Raman spectroscopy
    Wittrock, Adrian
    Heermant, Saskia
    Beckmann, Christian
    Wimmer, Markus A.
    Fischer, Alfons
    Aßmann, Marc
    Debus, Jörg
    Acta Biomaterialia, 2024, 189 : 621 - 632