Noninvasive pulse contour analysis for determination of cardiac output in patients with chronic heart failure

被引:15
|
作者
Roth, Sebastian [1 ]
Fox, Henrik [1 ]
Fuchs, Uwe [2 ]
Schulz, Uwe [2 ]
Costard-Jaeckle, Angelika [2 ]
Gummert, Jan F. [2 ]
Horstkotte, Dieter [1 ]
Oldenburg, Olaf [1 ]
Bitter, Thomas [1 ]
机构
[1] Ruhr Univ Bochum, Clin Cardiol, Herz & Diabet Zentrum NRW, Georgstr 11, D-32545 Bad Oeynhausen, Germany
[2] Ruhr Univ Bochum, Clin Thorac & Cardiovasc Surg, Herz & Diabet Zentrum NRW, Georgstr 11, D-32545 Bad Oeynhausen, Germany
关键词
Heart failure; Cardiac output; Pulmonary artery catheter; Noninvasive pulse contour analysis; CNAP monitor; PULMONARY-ARTERY CATHETER; PRESSURE; METAANALYSIS; PRECISION; AGREEMENT; THERMODILUTION; ACCURACY; GERMANY; SYSTEM; DEVICE;
D O I
10.1007/s00392-017-1198-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Determination of cardiac output (CO) is essential in diagnosis and management of heart failure (HF). The gold standard to obtain CO is invasive assessment via thermodilution (TD). Noninvasive pulse contour analysis (NPCA) is supposed as a new method of CO determination. However, a validation of this method in HF is pending and performed in the present study. Methods Patients with chronic-stable HF and reduced left ventricular ejection fraction (LVEF = 45%; HF-REF) underwent right heart catheterization including TD. NPCA using the CNAP Monitor (V5.2.14, CNSystems Medizintechnik AG) was performed simultaneously. Three standardized TD measurements were compared with simultaneous auto-calibrated NPCA CO measurements. Results In total, 84 consecutive HF-REF patients were enrolled prospectively in this study. In 4 patients (5%), TD was not successful and for 22 patients (26%, 18 with left ventricular assist device), no NPCA signal could be obtained. For the remaining 58 patients, Bland-Altman analysis revealed a mean bias of + 1.92 L/min (limits of agreement +/- 2.28 L/min, percentage error 47.4%) for CO. With decreasing cardiac index, as determined by the gold standard of TD, there was an increasing gap between CO values obtained by TD and NPCA (r = -0.75, p < 0.001), resulting in a systematic overestimation of CO in more severe HF. TD-CI classified 52 (90%) patients to have a reduced CI (< 2.5 L/min/m(2)), while NPCA documented a reduced CI in 18 patients (31%) only. Conclusions In HF-REF patients, auto-calibrated NPCA systematically overestimates CO with decrease in cardiac function. Therefore, to date, NPCA cannot be recommended in this cohort.
引用
收藏
页码:395 / 404
页数:10
相关论文
共 50 条
  • [31] Accuracy of cardiac output monitoring by continuous pulse contour analysis in hemodynamic instable patients
    Godje, O
    Friedl, R
    Hannekum, A
    CRITICAL CARE MEDICINE, 2001, 29 (12) : A118 - A118
  • [32] Validation of cardiac output measurements utilizing arterial pulse contour analysis by Vigileo™ in cardiac surgery patients
    Kumaran, Rani
    Hwang, James
    Mansuroglu, Naim
    Oribabor, Charles
    Skubas, Nikolaos
    Osario, James
    Tortolani, Anthony
    Lee, Leonard
    Kurugundla, Navatha
    Devakonda, Arun
    Bernstein, Larry
    Sung, Arthur
    Raoof, Suhail
    CRITICAL CARE MEDICINE, 2007, 35 (12) : A77 - A77
  • [33] Continuous cardiac output measurement:: pulse contour analysis vs thermodilution technique in cardiac surgical patients
    Rödig, G
    Prasser, C
    Keyl, C
    Liebold, A
    Hobbhahn, J
    BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 (04) : 525 - 530
  • [34] Perioperative pulse contour cardiac output analysis in a patient with severe cardiac dysfunction
    Jones, D
    Story, D
    Peyton, P
    Bellomo, R
    ANAESTHESIA AND INTENSIVE CARE, 2006, 34 (01) : 97 - 101
  • [35] Noninvasive determination of pulmonary artery wedge pressure in patients with chronic heart failure
    Givertz, MM
    Slawsky, MT
    Moraes, DL
    McIntyre, KM
    Colucci, WS
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (10): : 1213 - +
  • [36] P2.25: Echocardiographic Validation of a Novel Method for Noninvasive Estimation of Cardiac Output Based on Pulse Contour Analysis
    T. G. Papaioannou
    D. Soulis
    O. Vardoulis
    A. D. Protogerou
    P. Sfikakis
    N. Stergiopulos
    C. Stefanadis
    Artery Research, 2013, 7 (3-4) : 126 - 126
  • [37] A new pulse contour cardiac output algorithm
    Linton, NW
    Linton, RA
    ANESTHESIOLOGY, 2000, 93 (3A) : U148 - U148
  • [38] Noninvasive Cardiac Output Measurement in Heart Failure Subjects on Circulatory Support
    Phillips, Rob
    Lichtenthal, Peter
    Sloniger, Julie
    Burstow, Darryl
    West, Malcolm
    Copeland, Jack
    ANESTHESIA AND ANALGESIA, 2009, 108 (03): : 881 - 886
  • [39] AORTIC PULSE CONTOUR CALCULATION OF CARDIAC OUTPUT
    GRAVES, CL
    STAUFFER, WM
    KLEIN, RL
    UNDERWOOD, PS
    ANESTHESIOLOGY, 1968, 29 (03) : 580 - +
  • [40] Use of lithium dilution and pulse contour analysis cardiac output determination in anaesthetized horses: a clinical evaluation
    Hallowell, GD
    Corley, KTT