Noninvasive pulse contour analysis for determination of cardiac output in patients with chronic heart failure

被引:15
|
作者
Roth, Sebastian [1 ]
Fox, Henrik [1 ]
Fuchs, Uwe [2 ]
Schulz, Uwe [2 ]
Costard-Jaeckle, Angelika [2 ]
Gummert, Jan F. [2 ]
Horstkotte, Dieter [1 ]
Oldenburg, Olaf [1 ]
Bitter, Thomas [1 ]
机构
[1] Ruhr Univ Bochum, Clin Cardiol, Herz & Diabet Zentrum NRW, Georgstr 11, D-32545 Bad Oeynhausen, Germany
[2] Ruhr Univ Bochum, Clin Thorac & Cardiovasc Surg, Herz & Diabet Zentrum NRW, Georgstr 11, D-32545 Bad Oeynhausen, Germany
关键词
Heart failure; Cardiac output; Pulmonary artery catheter; Noninvasive pulse contour analysis; CNAP monitor; PULMONARY-ARTERY CATHETER; PRESSURE; METAANALYSIS; PRECISION; AGREEMENT; THERMODILUTION; ACCURACY; GERMANY; SYSTEM; DEVICE;
D O I
10.1007/s00392-017-1198-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Determination of cardiac output (CO) is essential in diagnosis and management of heart failure (HF). The gold standard to obtain CO is invasive assessment via thermodilution (TD). Noninvasive pulse contour analysis (NPCA) is supposed as a new method of CO determination. However, a validation of this method in HF is pending and performed in the present study. Methods Patients with chronic-stable HF and reduced left ventricular ejection fraction (LVEF = 45%; HF-REF) underwent right heart catheterization including TD. NPCA using the CNAP Monitor (V5.2.14, CNSystems Medizintechnik AG) was performed simultaneously. Three standardized TD measurements were compared with simultaneous auto-calibrated NPCA CO measurements. Results In total, 84 consecutive HF-REF patients were enrolled prospectively in this study. In 4 patients (5%), TD was not successful and for 22 patients (26%, 18 with left ventricular assist device), no NPCA signal could be obtained. For the remaining 58 patients, Bland-Altman analysis revealed a mean bias of + 1.92 L/min (limits of agreement +/- 2.28 L/min, percentage error 47.4%) for CO. With decreasing cardiac index, as determined by the gold standard of TD, there was an increasing gap between CO values obtained by TD and NPCA (r = -0.75, p < 0.001), resulting in a systematic overestimation of CO in more severe HF. TD-CI classified 52 (90%) patients to have a reduced CI (< 2.5 L/min/m(2)), while NPCA documented a reduced CI in 18 patients (31%) only. Conclusions In HF-REF patients, auto-calibrated NPCA systematically overestimates CO with decrease in cardiac function. Therefore, to date, NPCA cannot be recommended in this cohort.
引用
收藏
页码:395 / 404
页数:10
相关论文
共 50 条
  • [1] Noninvasive pulse contour analysis for determination of cardiac output in patients with chronic heart failure
    Sebastian Roth
    Henrik Fox
    Uwe Fuchs
    Uwe Schulz
    Angelika Costard-Jäckle
    Jan F. Gummert
    Dieter Horstkotte
    Olaf Oldenburg
    Thomas Bitter
    Clinical Research in Cardiology, 2018, 107 : 395 - 404
  • [2] Pulse contour cardiac output monitoring in acute heart failure patients
    Wernly, Bernhard
    Lichtenauer, Michael
    Franz, Marcus
    Fritzenwanger, Michael
    Kabisch, Bjoern
    Figulla, Hans-Reiner
    Jung, Christian
    WIENER KLINISCHE WOCHENSCHRIFT, 2016, 128 (23-24) : 864 - 869
  • [3] Evaluation of noninvasive exercise cardiac output determination in chronic heart failure patients: a proposal of a new diagnostic and prognostic method
    Cattadori, Gaia
    Salvioni, Elisabetta
    Gondoni, Erica
    Agostoni, Piergiuseppe
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2011, 12 (01) : 19 - 27
  • [4] Noninvasive cardiac output determination using applanation tonometry-derived radial artery pulse contour analysis in critically ill patients
    Compton, Friederike
    Wittrock, Marc
    Schaefer, Juergen-Heiner
    Zidek, Walter
    Tepel, Martin
    Scholze, Alexandra
    ANESTHESIA AND ANALGESIA, 2008, 106 (01): : 171 - 174
  • [5] Output performance: cardiac output by pulse contour analysis
    Haskins, Steve C.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2011, 21 (04) : 305 - 308
  • [6] Noninvasive cardiac output measurement in orthostasis: pulse contour analysis compared with acetylene rebreathing
    Stok, WJ
    Stringer, RCO
    Karemaker, JM
    JOURNAL OF APPLIED PHYSIOLOGY, 1999, 87 (06) : 2266 - 2273
  • [7] Pulse contour analysis for cardiac output monitoring in cardiac surgery for congenital heart disease
    Mahajan, A
    Shabanie, A
    Turner, J
    Sopher, MJ
    Marijic, J
    ANESTHESIA AND ANALGESIA, 2003, 97 (05): : 1283 - 1288
  • [8] Pulse contour cardiac output monitoring in acute heart failure patientsAssessment of hemodynamic measurements
    Bernhard Wernly
    Michael Lichtenauer
    Marcus Franz
    Michael Fritzenwanger
    Bjoern Kabisch
    Hans-Reiner Figulla
    Christian Jung
    Wiener klinische Wochenschrift, 2016, 128 : 864 - 869
  • [9] Pulse contour analysis to estimate cardiac output
    Linton, Nick
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2006, 53 (08): : 850 - 851
  • [10] Continuous cardiac output by pulse contour analysis?
    van Lieshout, JJ
    Wesseling, KH
    BRITISH JOURNAL OF ANAESTHESIA, 2001, 86 (04) : 467 - 469