Validation of a semi-automated scintigraphic technique for detecting episodic, real-time colonic flow

被引:3
|
作者
Dinning, P. G.
McKay, E.
Cook, I. J. [1 ]
机构
[1] Univ New S Wales, St George Hosp, Dept Gastroenterol, Kogarah, NSW 2217, Australia
[2] Univ New S Wales, St George Hosp, Dept Nucl Med, Kogarah, NSW 2217, Australia
来源
NEUROGASTROENTEROLOGY AND MOTILITY | 2006年 / 18卷 / 07期
关键词
colon; luminal flow; quantitative technique; scintigraphy;
D O I
10.1111/j.1365-2982.2006.00796.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
The relationships between the movement of colonic content and regional pressures have only been partially defined. During the analysis of a combined colonic scintigraphic and manometric study, a quantitative technique for determining discrete, episodic, real-time colonic flow was developed. Our aim was to validate this technique through the construction of a computer-generated phantom model of known antegrade and retrograde motility. The anthropoid phantom was rasterized into a 6-mm voxel model to create a 3D voxel phantom of the colon with four distinct colonic segments. Associating a time/activity curve with each segment simulated dynamic behaviour. Activity in the model was based on data obtained from human colonic scintigraphic recordings using 30 MBq of Tc-99m sulphur colloid. The flow was simulated by modifying the input time/activity functions to represent episodes of net flow of 2%, 5% or 10% of segmental content. Our quantitative technique was applied to the phantom model to measure the accuracy with which simulated flows were detected. Our quantitative technique proved to be a sensitive and specific means of detecting the presence and the magnitude of discrete episodes of colonic flow and therefore, should improve our ability to correlate colonic flow and motor patterns.
引用
收藏
页码:547 / 555
页数:9
相关论文
共 50 条
  • [21] Statistically Biased Calibration Method for the Real-time Adjustment of Noninvasive Haemoglobin Measurements in a Semi-automated Infusion System
    Markevicius, V.
    Andrijauskas, A.
    Navikas, D.
    Svensen, C.
    Porvaneckas, N.
    Andriukaitis, D.
    Kvederas, G.
    Cincikas, D.
    Andrijauskas, P.
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2013, 19 (07) : 65 - 71
  • [22] Evaluation of an automated real-time spectral analysis technique
    Rickey, DW
    Fenster, A
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (01): : 61 - 73
  • [23] Profiling of human epigenetic regulators using a semi-automated real-time qPCR platform validated by next generation sequencing
    Dudakovic, Amel
    Gluscevic, Martina
    Paradise, Christopher R.
    Dudakovic, Halil
    Khani, Farzaneh
    Thaler, Roman
    Ahmed, Farah S.
    Li, Xiaodong
    Dietz, Allan B.
    Stein, Gary S.
    Montecino, Martin A.
    Deyle, David R.
    Westendorf, Jennifer J.
    van Wijnen, Andre J.
    GENE, 2017, 609 : 28 - 37
  • [24] Real-Time, Semi-Automated Fluorescent Measurement of the Airway Surface Liquid pH of Primary Human Airway Epithelial Cells
    Saint-Criq, Vinciane
    Haq, Iram J.
    Gardner, Aaron, I
    Garnett, James P.
    Ward, Christopher
    Brodlie, Malcolm
    Gray, Michael A.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2019, (148):
  • [25] Diagnosis of feline filariasis assisted by a novel semi-automated microfluidic device in combination with high resolution melting real-time PCR
    Phuakrod, Achinya
    Sripumkhai, Witsaroot
    Jeamsaksiri, Wutthinan
    Pattamang, Pattaraluck
    Juntasaro, Ekachai
    Thienthong, Therdthai
    Foongladda, Suporn
    Brindley, Paul J.
    Wongkamchai, Sirichit
    PARASITES & VECTORS, 2019, 12 (1)
  • [26] Vision-based real-time position control of a semi-automated system for robot-assisted joint fracture surgery
    Giulio Dagnino
    Ioannis Georgilas
    Payam Tarassoli
    Roger Atkins
    Sanja Dogramadzi
    International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 437 - 455
  • [27] Diagnosis of feline filariasis assisted by a novel semi-automated microfluidic device in combination with high resolution melting real-time PCR
    Achinya Phuakrod
    Witsaroot Sripumkhai
    Wutthinan Jeamsaksiri
    Pattaraluck Pattamang
    Ekachai Juntasaro
    Therdthai Thienthong
    Suporn Foongladda
    Paul J. Brindley
    Sirichit Wongkamchai
    Parasites & Vectors, 12
  • [28] A novel semi-automated algorithm for analysis of right ventricular volume and function by real-time 3-dimensional echocardiography in children
    Lu, Xiuzhang
    Xie, Mingxing
    Nadvoretskiy, Vyacheslav
    Klas, Berthold
    Ayres, Nancy
    CIRCULATION, 2007, 116 (16) : 512 - 512
  • [29] ASSESSMENT AND COMPARISON OF EFFLUX PUMPS OF CANCER CELLS AND MDR BACTERIA UNDER PHYSIOLOGICAL CONDITIONS BY A REAL-TIME SEMI-AUTOMATED SYSTEM
    Amaral, Leonard
    Spengler, Gabriella
    Viveiros, Miguel
    Rodrigues, Liliana
    Martins, Ana
    Couto, Isabel
    Martins, Marta
    Fanning, Seamus
    Pages, Jean-Marie
    Molnar, Joseph
    ANTICANCER RESEARCH, 2008, 28 (5C) : 3193 - 3194
  • [30] Vision-based real-time position control of a semi-automated system for robot-assisted joint fracture surgery
    Dagnino, Giulio
    Georgilas, Ioannis
    Tarassoli, Payam
    Atkins, Roger
    Dogramadzi, Sanja
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (03) : 437 - 455