Validation of a semi-automated scintigraphic technique for detecting episodic, real-time colonic flow

被引:3
|
作者
Dinning, P. G.
McKay, E.
Cook, I. J. [1 ]
机构
[1] Univ New S Wales, St George Hosp, Dept Gastroenterol, Kogarah, NSW 2217, Australia
[2] Univ New S Wales, St George Hosp, Dept Nucl Med, Kogarah, NSW 2217, Australia
来源
NEUROGASTROENTEROLOGY AND MOTILITY | 2006年 / 18卷 / 07期
关键词
colon; luminal flow; quantitative technique; scintigraphy;
D O I
10.1111/j.1365-2982.2006.00796.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
The relationships between the movement of colonic content and regional pressures have only been partially defined. During the analysis of a combined colonic scintigraphic and manometric study, a quantitative technique for determining discrete, episodic, real-time colonic flow was developed. Our aim was to validate this technique through the construction of a computer-generated phantom model of known antegrade and retrograde motility. The anthropoid phantom was rasterized into a 6-mm voxel model to create a 3D voxel phantom of the colon with four distinct colonic segments. Associating a time/activity curve with each segment simulated dynamic behaviour. Activity in the model was based on data obtained from human colonic scintigraphic recordings using 30 MBq of Tc-99m sulphur colloid. The flow was simulated by modifying the input time/activity functions to represent episodes of net flow of 2%, 5% or 10% of segmental content. Our quantitative technique was applied to the phantom model to measure the accuracy with which simulated flows were detected. Our quantitative technique proved to be a sensitive and specific means of detecting the presence and the magnitude of discrete episodes of colonic flow and therefore, should improve our ability to correlate colonic flow and motor patterns.
引用
收藏
页码:547 / 555
页数:9
相关论文
共 50 条
  • [11] A German Chlamydia trachomatis screening program employing semi-automated real-time PCR: results and perspectives
    Boehm, I.
    Groening, A.
    Sommer, B.
    Mueller, H. -W
    Krawczak, M.
    Glaubitz, R.
    JOURNAL OF CLINICAL VIROLOGY, 2009, 46 : S27 - S32
  • [12] Improved diagnosis of gastrointestinal infections using a semi-automated multiplex real-time PCR for detection of enteropathogens
    Fidalgo, Berta
    Rubio, Elisa
    Pastor, Victor
    Parera, Marta
    Balleste-Delpierre, Clara
    Fernandez, Mariana Jose
    Chasco, Genoveva Cuesta
    Vergara, Andrea
    Zboromyrska, Yuliya
    Aylagas, Cristian
    Salvador, Pilar
    Fernandez, Adan
    Valls, M. Eugenia
    Martinez, Miriam Jose Alvarez
    Mira, Aurea
    Marcos, Maria Angeles
    Vila, Jordi
    Martinez, Miguel J.
    Casals-Pascual, Climent
    JOURNAL OF MEDICAL MICROBIOLOGY, 2021, 70 (09)
  • [13] Semi-automated analysis of coronary flow Doppler images: Validation with manual tracings
    Magagnin, V.
    Caiani, E. G.
    Delfino, L.
    Champlon, C.
    Cerutti, S.
    Turiel, M.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 3703 - +
  • [14] Validation of semi-automated flow-mediated dilation measurement in healthy volunteers
    Dobbie, Laurence J.
    Mackin, Sharon T.
    Hogarth, Katrina
    Lonergan, Frances
    Kannenkeril, Dennis
    Brooksbank, Katriona
    Delles, Christian
    BLOOD PRESSURE MONITORING, 2020, 25 (04) : 216 - 223
  • [15] Semi-automated left ventricular function assessment by real-time three-dimensional echocardiography is ready for prime time
    Soliman, O. I. I.
    Van Dalen, B. M.
    Geleijnse, M. L.
    Vletter, W. B.
    Al-Amin, A. M.
    Ten Cate, F. J.
    EUROPEAN HEART JOURNAL, 2009, 30 : 342 - 342
  • [16] On Real-time Detecting Passenger Flow Anomalies
    Tang, Bo
    Tang, Hongyin
    Dong, Xinzhou
    Jin, Beihong
    Ge, Tingjian
    CIKM'18: PROCEEDINGS OF THE 27TH ACM INTERNATIONAL CONFERENCE ON INFORMATION AND KNOWLEDGE MANAGEMENT, 2018, : 1053 - 1062
  • [17] Semi-automated quantification of left ventricular volumes and ejection fraction by real-time three-dimensional echocardiography
    Hansegard, Joger
    Urheim, Stig
    Lunde, Ketil
    Malm, Siri
    Rabben, Stein Inge
    CARDIOVASCULAR ULTRASOUND, 2009, 7
  • [18] Analysis and Implementation of Threat Agents Profiles in Semi-Automated Manner for a Network Traffic in Real-Time Information Environment
    Sharma, Gaurav
    Vidalis, Stilianos
    Menon, Catherine
    Anand, Niharika
    Kumar, Somesh
    ELECTRONICS, 2021, 10 (15)
  • [19] Validation of a semi-automated computer-aided technique for quantifying corneal vascularisation and scarring
    Tatham, Andrew
    Tatham, Eric
    Prydal, Jeremy
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (10) : 1379 - 1384
  • [20] Semi-automated quantification of left ventricular volumes and ejection fraction by real-time three-dimensional echocardiography
    Jøger Hansegård
    Stig Urheim
    Ketil Lunde
    Siri Malm
    Stein Inge Rabben
    Cardiovascular Ultrasound, 7