Endovascular stent-anchored aortic grafts: A comparison between self-expanding and balloon-expandable stents in minipigs

被引:0
|
作者
Lindh, M
Malina, M
Ivancev, K
Brunkwall, J
Lindblad, B
机构
[1] LUND UNIV, MALMO UNIV HOSP, DEPT VASC SURG, S-20502 MALMO, SWEDEN
[2] KRISTIANSTAD CTY HOSP, DEPT SURG, KRISTIANSTAD, SWEDEN
来源
JOURNAL OF ENDOVASCULAR SURGERY | 1996年 / 3卷 / 03期
关键词
endoprostheses; stent-graft; stents; endoluminal graft; experimental study;
D O I
10.1583/1074-6218(1996)003<0284:ESAAGA>2.0.CO;2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To study endovascular graft attachment with self-expanding Gianturco Z-stents and balloon-expanded Palmaz stents and the effect of these devices on the renal ostia. Methods: Ten stent-grafts were constructed, 5 with Gianturco Z-stents and 5 with Palmaz stents. The endografts were implanted under fluoroscopic guidance into the abdominal aorta of 10 pigs so that the uncovered portion of the proximal stent extended over the renal artery orifices. Distal aortic blood pressure and Row were measured before and after graft placement and 1 hour postprocedure. The aorta was then exposed surgically, and the central portion of the stent-graft was inspected through an aortotomy to assess perigraft leakage. Results: Stent-graft implantation was accurate and hemostatic in all cases, despite longitudinal folding of the graft due to oversizing. However, transverse folds produced pressure gradients (> 15 mmHg) between the ends of the graft in two cases. In another case, a pressure gradient resulted from partial thrombosis of the graft. In two cases, renal artery occlusion and thrombosis occurred due to coverage by the graft material. In two other animals, one of the renal arteries was entirely uncovered by a stent. The remaining 16 renal arteries were covered by the proximal stent but not the graft, as intended. One (6.25%) of these arteries thrombosed, but the remainder were grossly patent when the animals were sacrificed at 1 hour. Conclusions: Both Palmaz and Gianturco Z-stents produced hemostatic endovascular graft attachment, even in the presence of moderate graft oversizing. The risk of acute renal artery occlusion from juxtarenal stenting does not appear to be prohibitive, but longer term observations are needed.
引用
收藏
页码:284 / 289
页数:6
相关论文
共 50 条
  • [1] Comparison of self-expanding and balloon-expandable stents for the reduction of restenosis
    Han, RO
    Schwartz, RS
    Kobayashi, Y
    Wilson, SH
    Mann, JT
    Sketch, MH
    Safian, RD
    Lansky, A
    Popma, J
    Fitzgerald, PJ
    Palacios, IF
    Chazin-Caldie, M
    Goldberg, S
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (03): : 253 - 259
  • [2] Performance of Viabahn Balloon-Expandable Stent Compared With Self-expanding Covered Stents for Fenestrated-Branched Endovascular Aortic Repair
    Motta, Fernando
    Parodi, Frederico E.
    Crowner, Jason R.
    Pas-Carella, Luigi
    McGinigle, Katharine L.
    Marston, William A.
    Kibbe, Melina R.
    Farber, Mark A.
    JOURNAL OF VASCULAR SURGERY, 2020, 71 (01) : E28 - E29
  • [3] Intracranial atherosclerosis: Treatment with balloon-expandable and self-expanding stents
    Niemann, David
    Turk, Aquilla S.
    Ahmed, Azam S.
    Pulfer, Kari A.
    Aagaard-Kienitz, Beverly
    Levine, Ross
    NEUROSURGERY, 2007, 61 (01) : 198 - 199
  • [4] Self-expanding or balloon-expandable transcatheter aortic valve replacement in a German comparison
    Oettinger, V.
    Hilgendorf, I.
    Wolf, D.
    Rilinger, J.
    Stachon, P.
    Kaier, K.
    Zehender, M.
    Westermann, D.
    Von Zur Muehlen, C.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [5] Self-Expanding or Balloon-Expandable TAVR with a Small Aortic Annulus
    Van Belle, Eric
    Vincent, Flavien
    Clavel, Marie Annick
    Fleming, Thomas R.
    Ternacle, Julien
    Modine, Thomas
    Abbas, Amr E.
    Pibarot, Philippe
    Hahn, Rebecca T.
    Herrmann, Howard C.
    Mehran, Roxana
    Tchetche, Didier
    NEW ENGLAND JOURNAL OF MEDICINE, 2024, 391 (10): : 964 - 967
  • [6] IMMEDIATE CHANGES IN STENOSIS GEOMETRY FOLLOWING STENT IMPLANTATION - COMPARISON BETWEEN A SELF-EXPANDING AND A BALLOON-EXPANDABLE STENT
    DEJAEGERE, PP
    STRAUSS, BH
    VANDERGIESSEN, WJ
    DEFEYTER, PJ
    SERRUYS, PW
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1992, 5 (02) : 71 - 78
  • [7] THROMBOCYTOPENIA AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT: A COMPARISON BETWEEN BALLOON-EXPANDABLE AND SELF-EXPANDING PROSTHESIS
    Pujol-Lopez, Margarida
    Hernandez-Enriquez, Marco
    Andrea, Rut
    Regueiro, Ander
    Antoni Gomez-Hospital, Joan
    Romaguera, Rafael
    Cequier, Angel
    Sabate, Manel
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1040 - 1040
  • [8] In Vitro Comparison of Self-Expanding Versus Balloon-Expandable Stents in a Human Ex Vivo Model
    Lars Grenacher
    Stefan Rohde
    Ellen Gänger
    Jochen Deutsch
    Günter W. Kauffmann
    Götz M. Richter
    CardioVascular and Interventional Radiology, 2006, 29 : 249 - 254
  • [9] Procedural Aspects of Transcatheter Aortic Valve Replacement: Comparison Between Balloon-Expandable and Self-Expanding Devices
    Andreka, Judit
    Stark, Cosima
    Deharo, Pierre
    Adamaszek, Martin
    Regueiro, Ander
    Prunea, Dan
    Maaroufi, Anass
    Ruzsa, Zoltan
    Cuisset, Thomas
    Schmidt, Albrecht
    Brugaletta, Salvatore
    Toth, Gabor
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B385 - B385
  • [10] In vitro comparison of self-expanding versus balloon-expandable stents in a human ex vivo model
    Grenacher, L
    Rohde, S
    Gänger, E
    Deutsch, J
    Kauffmann, GW
    Richter, GM
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 29 (02) : 249 - 254