IMMEDIATE CHANGES IN STENOSIS GEOMETRY FOLLOWING STENT IMPLANTATION - COMPARISON BETWEEN A SELF-EXPANDING AND A BALLOON-EXPANDABLE STENT

被引:0
|
作者
DEJAEGERE, PP [1 ]
STRAUSS, BH [1 ]
VANDERGIESSEN, WJ [1 ]
DEFEYTER, PJ [1 ]
SERRUYS, PW [1 ]
机构
[1] ERASMUS UNIV,THORAXCTR,CATHETERIZAT LAB,POB 1738,3000 DR ROTTERDAM,NETHERLANDS
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The immediate changes in stenosis geometry following Wallstent and Wiktor stent implantation in native coronary arteries were compared in 92 patients (46 in each group) using automated edge detection. Patients with comparable baseline stenosis characteristics were selected. Lesions were matched for lesion site, reference diameter, and minimal luminal diameter. In both groups, the stented coronary artery was the left anterior descending artery in 27 patients (59%), the left circumflex artery in four patients (9%), and the right coronary arte in 15 patients (33%). The baseline reference diameter was 2.86 +/- 0.39 mm and 2.87 +/- 0.42 mm in the Wallstent and Wiktor stent study group, respectively (NS). The baseline minimal luminal diameter was identical in both groups (1.13 +/- 0.24 mm). The nominal size (mean +/- SD) of the unconstrained Wallstent was 3.5 +/- 0.3 mm and 3.3 +/- 0.3 mm for the Wiktor stent (P < 0.05). Both types of stents resulted in a similar increase in minimal luminal diameter immediately following implantation (Wallstent: 2.34 +/- 0.38 mm, Wiktor stent: 2.43 +/- 0.27 mm, NS). Furthermore, there was a similar decrease in diameter stenosis and increase in minimal luminal cross-section area following implantation of both stents. These morphological changes were associated with a normalization of the hemodynamic parameters in both groups. It is concluded that, although the Wallstent and Wiktor stent are different in design and mechanical characteristics, there is a similar immediate improvement in stenosis geometry following implantation of both devices.
引用
收藏
页码:71 / 78
页数:8
相关论文
共 50 条
  • [1] Stent design-related coronary artery remodeling and patterns of neointima formation following self-expanding and balloon-expandable stent implantation
    König, A
    Schiele, TM
    Rieber, J
    Theisen, K
    Mudra, H
    Klauss, V
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 56 (04) : 478 - 486
  • [2] The effect of balloon-expandable stent and self-expanding stent on changes in mitral annular motion after aortic valve replacement in patients with aortic stenosis
    Daijiro Hori
    Yohei Nomura
    Yosuke Taniguchi
    Koichi Yuri
    Makiko Mieno
    Naoyuki Kimura
    Atsushi Yamaguchi
    Journal of Artificial Organs, 2024, 27 : 23 - 31
  • [3] The effect of balloon-expandable stent and self-expanding stent on changes in mitral annular motion after aortic valve replacement in patients with aortic stenosis
    Hori, Daijiro
    Nomura, Yohei
    Taniguchi, Yosuke
    Yuri, Koichi
    Mieno, Makiko
    Kimura, Naoyuki
    Yamaguchi, Atsushi
    JOURNAL OF ARTIFICIAL ORGANS, 2024, 27 (01) : 23 - 31
  • [4] Comparison of Acute Vessel Wall Injury After Self-Expanding Stent and Conventional Balloon-Expandable Stent Implantation: A Study with Optical Coherence Tomography
    Shin, Eun-Seok
    Garcia-Garcia, Hector M.
    Okamura, Takayuki
    Wykrzykowska, Joanna J.
    Gonzalo, Nieves
    Shen, Zu Jun
    van Geuns, Robert Jan
    Regar, Evelyn
    Serruys, Patrick W.
    JOURNAL OF INVASIVE CARDIOLOGY, 2010, 22 (09): : 435 - 439
  • [5] Endovascular stent-anchored aortic grafts: A comparison between self-expanding and balloon-expandable stents in minipigs
    Lindh, M
    Malina, M
    Ivancev, K
    Brunkwall, J
    Lindblad, B
    JOURNAL OF ENDOVASCULAR SURGERY, 1996, 3 (03): : 284 - 289
  • [6] Effect of balloon-expandable and self-expanding stent fixation on endoluminal polytetrafluoroethylene graft healing
    Ombrellaro, MP
    Stevens, SL
    Sciarrotta, J
    Schaeffer, DO
    Freeman, MB
    Goldman, MH
    AMERICAN JOURNAL OF SURGERY, 1997, 173 (06): : 461 - 466
  • [7] Comparison of the self-expanding radius stent and the balloon-expandable multilink stent for elective treatment of coronary stenoses: A serial analysis by intravascular ultrasound
    Yu, ZX
    Tamai, H
    Kyo, E
    Kosuga, K
    Hata, T
    Okada, M
    Nakamura, T
    Komori, H
    Tsuji, T
    Takeda, S
    Motohara, S
    Uehata, H
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 56 (01) : 40 - 45
  • [8] Self-Expanding Stent Peeling Away From Overlapping Balloon-Expandable Stent Causing Late Acquired Aneurysm Formation and Stent Malapposition
    Chan, Chi Yuen
    Wu, Eugene B.
    Yan, Bryan P.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (04) : E35 - E37
  • [9] Comparison of self-expanding and balloon-expandable stents for the reduction of restenosis
    Han, RO
    Schwartz, RS
    Kobayashi, Y
    Wilson, SH
    Mann, JT
    Sketch, MH
    Safian, RD
    Lansky, A
    Popma, J
    Fitzgerald, PJ
    Palacios, IF
    Chazin-Caldie, M
    Goldberg, S
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (03): : 253 - 259
  • [10] Thrombocytopenia after transcatheter aortic valve implantation. A comparison between balloon-expandable and self-expanding valves
    Hernandez-Enriquez, Marco
    Regueiro, Ander
    Romaguera, Rafael
    Andrea, Rut
    Antoni Gomez-Hospital, Joan
    Pujol-Lopez, Margarida
    Luis Ferreiro-Gutierrez, Jose
    Brugaletta, Salvatore
    Roura, Gerard
    Freixa, Xavier
    Gomez-Lara, Josep
    Martin-Yuste, Victoria
    Gracida, Montserrat
    Cequier, Angel
    Sabate, Manel
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 93 (07) : 1344 - 1351