Endovascular stent-anchored aortic grafts: A comparison between self-expanding and balloon-expandable stents in minipigs

被引:0
|
作者
Lindh, M
Malina, M
Ivancev, K
Brunkwall, J
Lindblad, B
机构
[1] LUND UNIV, MALMO UNIV HOSP, DEPT VASC SURG, S-20502 MALMO, SWEDEN
[2] KRISTIANSTAD CTY HOSP, DEPT SURG, KRISTIANSTAD, SWEDEN
来源
JOURNAL OF ENDOVASCULAR SURGERY | 1996年 / 3卷 / 03期
关键词
endoprostheses; stent-graft; stents; endoluminal graft; experimental study;
D O I
10.1583/1074-6218(1996)003<0284:ESAAGA>2.0.CO;2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To study endovascular graft attachment with self-expanding Gianturco Z-stents and balloon-expanded Palmaz stents and the effect of these devices on the renal ostia. Methods: Ten stent-grafts were constructed, 5 with Gianturco Z-stents and 5 with Palmaz stents. The endografts were implanted under fluoroscopic guidance into the abdominal aorta of 10 pigs so that the uncovered portion of the proximal stent extended over the renal artery orifices. Distal aortic blood pressure and Row were measured before and after graft placement and 1 hour postprocedure. The aorta was then exposed surgically, and the central portion of the stent-graft was inspected through an aortotomy to assess perigraft leakage. Results: Stent-graft implantation was accurate and hemostatic in all cases, despite longitudinal folding of the graft due to oversizing. However, transverse folds produced pressure gradients (> 15 mmHg) between the ends of the graft in two cases. In another case, a pressure gradient resulted from partial thrombosis of the graft. In two cases, renal artery occlusion and thrombosis occurred due to coverage by the graft material. In two other animals, one of the renal arteries was entirely uncovered by a stent. The remaining 16 renal arteries were covered by the proximal stent but not the graft, as intended. One (6.25%) of these arteries thrombosed, but the remainder were grossly patent when the animals were sacrificed at 1 hour. Conclusions: Both Palmaz and Gianturco Z-stents produced hemostatic endovascular graft attachment, even in the presence of moderate graft oversizing. The risk of acute renal artery occlusion from juxtarenal stenting does not appear to be prohibitive, but longer term observations are needed.
引用
收藏
页码:284 / 289
页数:6
相关论文
共 50 条
  • [41] SELF-EXPANDING AND BALLOON-EXPANDABLE STENTS IN THE TREATMENT OF CAROTID ANEURYSMS - AN EXPERIMENTAL-STUDY IN A CANINE MODEL
    WAKHLOO, AK
    SCHELLHAMMER, F
    DEVRIES, J
    HABERSTROH, J
    SCHUMACHER, M
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (03) : 493 - 502
  • [42] Neosinus and Sinus Flow After Self-Expanding and Balloon-Expandable Transcatheter Aortic Valve Replacement
    Hatoum, Hoda
    Gooden, Shelley C. M.
    Sathananthan, Janarthanan
    Sellers, Stephanie
    Kutting, Maximilian
    Marx, Philipp
    Lilly, Scott M.
    Ihdayhid, Abdul R.
    Thourani, Vinod H.
    Dasi, Lakshmi Prasad
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (24) : 2657 - 2666
  • [44] Outcomes of Directional Branches Using Self-Expandable Versus Balloon-Expandable Stent Grafts During Endovascular Repair of Thoracoabdominal Aortic Aneurysms
    Tenorio, Emanuel R.
    Karkkainen, Jussi M.
    Mendes, Bernardo C.
    DeMartino, Randall R.
    Wigham, Jean
    Diderrich, Alisa
    Hofer, Jan
    Oderich, Gustavo S.
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (03) : E26 - E26
  • [45] Angiographic outcomes in self-expanding and balloon-expandable stents: Importance of procedural technique in determining late patency
    Wilson, SH
    Han, RO
    Schwartz, RS
    Goldberg, S
    CIRCULATION, 1998, 98 (17) : 160 - 160
  • [46] Comparison of the self-expanding radius stent and the balloon-expandable multilink stent for elective treatment of coronary stenoses: A serial analysis by intravascular ultrasound
    Yu, ZX
    Tamai, H
    Kyo, E
    Kosuga, K
    Hata, T
    Okada, M
    Nakamura, T
    Komori, H
    Tsuji, T
    Takeda, S
    Motohara, S
    Uehata, H
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 56 (01) : 40 - 45
  • [47] New CENTERA Transcatheter Aortic Valve Best of the Balloon-Expandable and Self-Expanding Valve Worlds?
    Yeung, Alan C.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (07) : 681 - 683
  • [48] LONG-TERM OUTCOMES OF BALLOON-EXPANDABLE VERSUS SELF-EXPANDING TRANSCATHETER AORTIC VALVES
    Patail, Haris
    Kompella, Ritika
    Bihag, Zade
    Haider, Jawad
    Lorenz, David P.
    Piccirillo, Bryan
    Azemi, Talhat
    Hoover, Nicole
    Hagberg, Robert
    Mather, Jeffrey
    Hashim, Sabet
    McKay, Raymond G.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 974 - 974
  • [49] Self-Expanding Versus Balloon-Expandable Stents for Iliac Artery Occlusive Disease The Randomized ICE Trial
    Krankenberg, Hans a
    Zeller, Thomas b
    Ingwersen, Maja a
    Schmalstieg, Josefin c
    Gissler, Hans Martin d
    Nikol, Sigrid e
    Baumgartner, Iris f
    Diehm, Nicolas g
    Nickling, Estell a
    Mueller-Huelsbeck, Stefan h
    Schmiedel, Rainer i
    Torsello, Giovanni j
    Hochholzer, Willibald k
    Stelzner, Christian l
    Brechtel, Klaus m
    Ito, Wulf n
    Kickuth, Ralph o
    Blessing, Erwin p
    Thieme, Marcus q
    Nakonieczny, Jaroslaw r
    Nolte, Thomas s
    Gareis, Ragnar t
    Boden, Harald u
    Sixt, Sebastian f
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (16) : 1694 - 1704
  • [50] A comparison of balloon- and self-expanding stents
    Duerig, TW
    Wholey, M
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2002, 11 (04) : 173 - 178