Determination of Caffeine, Myosmine, and Nicotine in Chocolate by Headspace Solid-Phase Microextraction Coupled with Gas Chromatography-Tandem Mass Spectrometry

被引:25
|
作者
Mueller, Christoph [1 ]
Vetter, Florian [1 ]
Richter, Elmar [2 ]
Bracher, Franz [1 ]
机构
[1] Univ Munich, Ctr Drug Res, Dept Pharm, D-81377 Munich, Germany
[2] Univ Munich, Dept Toxicol, Walther Straub Inst, D-80336 Munich, Germany
关键词
caffeine; chocolate; myosmine; nicotine; solid-phase microextraction; WASTE-WATER; COTININE; PHARMACEUTICALS; THEOBROMINE; PRODUCTS; URINE;
D O I
10.1111/1750-3841.12339
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The occurrence of the bioactive components caffeine (xanthine alkaloid), myosmine and nicotine (pyridine alkaloids) in different edibles and plants is well known, but the content of myosmine and nicotine is still ambiguous in milk/dark chocolate. Therefore, a sensitive method for determination of these components was established, a simple separation of the dissolved analytes from the matrix, followed by headspace solid-phase microextraction coupled with gas chromatography-tandem mass spectrometry (HS-SPME-GC-MS/MS). This is the first approach for simultaneous determination of caffeine, myosmine, and nicotine with a convenient SPME technique. Calibration curves were linear for the xanthine alkaloid (250 to 3000 mg/kg) and the pyridine alkaloids (0.000125 to 0.003000 mg/kg). Residuals of the calibration curves were lower than 15%, hence the limits of detection were set as the lowest points of the calibration curves. The limits of detection calculated from linearity data were for caffeine 216 mg/kg, for myosmine 0.000110 mg/kg, and for nicotine 0.000120 mg/kg. Thirty samples of 5 chocolate brands with varying cocoa contents (30% to 99%) were analyzed in triplicate. Caffeine and nicotine were detected in all samples of chocolate, whereas myosmine was not present in any sample. The caffeine content ranged from 420 to 2780 mg/kg (relative standard deviation 0.1 to 11.5%) and nicotine from 0.000230 to 0.001590 mg/kg (RSD 2.0 to 22.1%). Practical Application We worked out a method for simultaneous determination of the alkaloids caffeine, myosmine and nicotine in the complex matrix chocolate using modern sample preparation and chromatographic techniques. This method allows the determination of the bioactive compounds in spite of the strongly different ranges for caffeine (420 to 2780 mg/kg) and for myosmine (below limit of detection) and nicotine (0.000230 to 0.001590 mg/kg). The content of caffeine and of the hitherto undetected nicotine correlated with the content of cocoa (30 to 99%) in the chocolate brands.
引用
收藏
页码:T251 / T255
页数:5
相关论文
共 50 条
  • [31] Headspace solid phase microextraction in-situ supercritical fluid extraction coupled to gas chromatography-tandem mass spectrometry for simultaneous determination of perfluorocarboxylic acids in sediments
    Liu, Wen-Lin
    Hwang, Bao-Huey
    Li, Zu-Guang
    Jen, Jen-Fon
    Lee, Maw-Rong
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (43) : 7857 - 7863
  • [32] Pressurised hot water extraction followed by headspace solid-phase microextraction and gas chromatography-tandem mass spectrometry for the determination of N-nitrosamines in sewage sludge
    Llop, Anna
    Borrull, Francesc
    Pocurull, Eva
    TALANTA, 2012, 88 : 284 - 289
  • [33] The Application of Headspace Solid-phase Microextraction as a Preparation Approach for Gas Chromatography with Mass Spectrometry
    Jerkovic, I
    Marijanovic, Z.
    Radonic, A.
    Zekic, M.
    Kranjac, M.
    KEMIJA U INDUSTRIJI-JOURNAL OF CHEMISTS AND CHEMICAL ENGINEERS, 2020, 69 (9-10): : 515 - 520
  • [34] Headspace solid-phase microextraction in combination with gas chromatography and tandem mass spectrometry for the determination of organochlorine and organophosphorus pesticides in whole human blood
    Hernández, F
    Pitarch, E
    Beltran, J
    López, FJ
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 769 (01): : 65 - 77
  • [35] Headspace solid-phase microextraction followed by gas chromatography tandem mass spectrometry for the sensitive determination of benzotriazole UV stabilizers in water samples
    Carpinteiro, Inmaculada
    Abuin, Brais
    Rodriguez, Isaac
    Cela, Rafael
    Ramil, Maria
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (02) : 829 - 839
  • [36] Headspace solid-phase microextraction followed by gas chromatography tandem mass spectrometry for the sensitive determination of benzotriazole UV stabilizers in water samples
    Inmaculada Carpinteiro
    Brais Abuín
    Isaac Rodríguez
    Rafael Cela
    Maria Ramil
    Analytical and Bioanalytical Chemistry, 2010, 397 : 829 - 839
  • [37] Static headspace, solid-phase microextraction and headspace solid-phase microextraction for BTEX determination in aqueous samples by gas chromatography
    Menéndez, JCF
    Sánchez, MLF
    Uría, JES
    Martínez, EF
    Sanz-Medel, A
    ANALYTICA CHIMICA ACTA, 2000, 415 (1-2) : 9 - 20
  • [38] Trace analysis of parabens, triclosan and related chlorophenols in water by headspace solid-phase microextraction with in situ derivatization and gas chromatography-tandem mass spectrometry
    Regueiro, Jorge
    Becerril, Elias
    Garcia-Jares, Carmen
    Llompart, Maria
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (23) : 4693 - 4702
  • [39] Determination of multiclass personal care products in continental waters by solid-phase microextraction followed by gas chromatography-tandem mass spectrometry
    Celeiro, Maria
    Pablo Lamas, J.
    Vila, Marlene
    Garcia-Jares, Carmen
    Homem, Vera
    Ratola, Nuno
    Dagnac, Thierry
    Llompart, Maria
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1607
  • [40] Sampling and analysis of polychlorinated biphenyls in indoor air by sorbent enrichment followed by headspace solid-phase microextraction and gas chromatography-tandem mass spectrometry
    Barro, R
    Ares, S
    Garcia-Jares, C
    Llompart, M
    Cela, R
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1072 (01) : 99 - 106