Determination of Caffeine, Myosmine, and Nicotine in Chocolate by Headspace Solid-Phase Microextraction Coupled with Gas Chromatography-Tandem Mass Spectrometry

被引:25
|
作者
Mueller, Christoph [1 ]
Vetter, Florian [1 ]
Richter, Elmar [2 ]
Bracher, Franz [1 ]
机构
[1] Univ Munich, Ctr Drug Res, Dept Pharm, D-81377 Munich, Germany
[2] Univ Munich, Dept Toxicol, Walther Straub Inst, D-80336 Munich, Germany
关键词
caffeine; chocolate; myosmine; nicotine; solid-phase microextraction; WASTE-WATER; COTININE; PHARMACEUTICALS; THEOBROMINE; PRODUCTS; URINE;
D O I
10.1111/1750-3841.12339
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The occurrence of the bioactive components caffeine (xanthine alkaloid), myosmine and nicotine (pyridine alkaloids) in different edibles and plants is well known, but the content of myosmine and nicotine is still ambiguous in milk/dark chocolate. Therefore, a sensitive method for determination of these components was established, a simple separation of the dissolved analytes from the matrix, followed by headspace solid-phase microextraction coupled with gas chromatography-tandem mass spectrometry (HS-SPME-GC-MS/MS). This is the first approach for simultaneous determination of caffeine, myosmine, and nicotine with a convenient SPME technique. Calibration curves were linear for the xanthine alkaloid (250 to 3000 mg/kg) and the pyridine alkaloids (0.000125 to 0.003000 mg/kg). Residuals of the calibration curves were lower than 15%, hence the limits of detection were set as the lowest points of the calibration curves. The limits of detection calculated from linearity data were for caffeine 216 mg/kg, for myosmine 0.000110 mg/kg, and for nicotine 0.000120 mg/kg. Thirty samples of 5 chocolate brands with varying cocoa contents (30% to 99%) were analyzed in triplicate. Caffeine and nicotine were detected in all samples of chocolate, whereas myosmine was not present in any sample. The caffeine content ranged from 420 to 2780 mg/kg (relative standard deviation 0.1 to 11.5%) and nicotine from 0.000230 to 0.001590 mg/kg (RSD 2.0 to 22.1%). Practical Application We worked out a method for simultaneous determination of the alkaloids caffeine, myosmine and nicotine in the complex matrix chocolate using modern sample preparation and chromatographic techniques. This method allows the determination of the bioactive compounds in spite of the strongly different ranges for caffeine (420 to 2780 mg/kg) and for myosmine (below limit of detection) and nicotine (0.000230 to 0.001590 mg/kg). The content of caffeine and of the hitherto undetected nicotine correlated with the content of cocoa (30 to 99%) in the chocolate brands.
引用
收藏
页码:T251 / T255
页数:5
相关论文
共 50 条
  • [21] Determination of fluoroquinolones in environmental waters by in-tube solid-phase microextraction coupled with liquid chromatography-tandem mass spectrometry
    Mitani, K
    Kataoka, H
    ANALYTICA CHIMICA ACTA, 2006, 562 (01) : 16 - 22
  • [22] Single step determination of fragrances in Cucurbita flowers by coupling headspace solid-phase microextraction low-pressure gas chromatography-tandem mass spectrometry
    Granero, AM
    González, FJE
    Frenich, AG
    Sanz, JMG
    Vidal, JLM
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1045 (1-2) : 173 - 179
  • [23] Direct monitoring of ochratoxin A in cheese with solid-phase microextraction coupled to liquid chromatography-tandem mass spectrometry
    Zhang, Xu
    Cudjoe, Erasmus
    Vuckovic, Dajana
    Pawliszyn, Janusz
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (44) : 7505 - 7509
  • [24] Determination of the Volatiles in Opuntia dillenii by Headspace Solid-Phase Microextraction and Gas Chromatography-Mass Spectrometry
    Xu, Feng
    Wang, Yuanmin
    Wu, Hongmei
    Wang, Xiangpei
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2015, 43 (04) : 446 - 452
  • [25] Determination of ethylphenols in wine by in situ derivatisation and headspace solid-phase microextraction–gas chromatography–mass spectrometry
    José David Carrillo
    María Teresa Tena
    Analytical and Bioanalytical Chemistry, 2007, 387 : 2547 - 2558
  • [26] Headspace solid-phase microextraction and gas chromatography−mass spectrometry for determination of cannabinoids in human breast milk
    Gabriela de Oliveira Silveira
    Silvana Loddi
    Carolina Dizioli Rodrigues de Oliveira
    Alexandre Dias Zucoloto
    Ligia Veras Gimenez Fruchtengarten
    Mauricio Yonamine
    Forensic Toxicology, 2017, 35 : 125 - 132
  • [27] Determination of phthalates and adipate in bottled water by headspace solid-phase microextraction and gas chromatography/mass spectrometry
    Cao, Xu-Liang
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1178 (1-2) : 231 - 238
  • [28] Determination of trichloroethylene from adipose tissue by headspace solid-phase microextraction gas chromatography/mass spectrometry
    Liu, Yongzhen
    Muralidhara, Srinivasa
    Bruckner, James V.
    Bartlett, Michael G.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (03) : 455 - 458
  • [29] Determination of metaldehyde in human serum by headspace solid-phase microextraction and gas chromatography-mass spectrometry
    Saito, Takeshi
    Morita, Seiji
    Motojyuku, Megumi
    Akieda, Kazuki
    Otsuka, Hiroyuki
    Yamamoto, Isotoshi
    Inokuchi, Sadaki
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 875 (02): : 573 - 576
  • [30] Determination of butyl xanthate in water by headspace solid-phase microextraction and gas chromatography-mass spectrometry
    Zhang, Jingkai
    Gu, Xuehua
    Yan, Shukai
    Gu, Yating
    Yao, Bin
    Gu, Ying
    Chinese Journal of Analysis Laboratory, 2021, 40 (06) : 727 - 730