Determination of Caffeine, Myosmine, and Nicotine in Chocolate by Headspace Solid-Phase Microextraction Coupled with Gas Chromatography-Tandem Mass Spectrometry

被引:23
|
作者
Mueller, Christoph [1 ]
Vetter, Florian [1 ]
Richter, Elmar [2 ]
Bracher, Franz [1 ]
机构
[1] Univ Munich, Ctr Drug Res, Dept Pharm, D-81377 Munich, Germany
[2] Univ Munich, Dept Toxicol, Walther Straub Inst, D-80336 Munich, Germany
关键词
caffeine; chocolate; myosmine; nicotine; solid-phase microextraction; WASTE-WATER; COTININE; PHARMACEUTICALS; THEOBROMINE; PRODUCTS; URINE;
D O I
10.1111/1750-3841.12339
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The occurrence of the bioactive components caffeine (xanthine alkaloid), myosmine and nicotine (pyridine alkaloids) in different edibles and plants is well known, but the content of myosmine and nicotine is still ambiguous in milk/dark chocolate. Therefore, a sensitive method for determination of these components was established, a simple separation of the dissolved analytes from the matrix, followed by headspace solid-phase microextraction coupled with gas chromatography-tandem mass spectrometry (HS-SPME-GC-MS/MS). This is the first approach for simultaneous determination of caffeine, myosmine, and nicotine with a convenient SPME technique. Calibration curves were linear for the xanthine alkaloid (250 to 3000 mg/kg) and the pyridine alkaloids (0.000125 to 0.003000 mg/kg). Residuals of the calibration curves were lower than 15%, hence the limits of detection were set as the lowest points of the calibration curves. The limits of detection calculated from linearity data were for caffeine 216 mg/kg, for myosmine 0.000110 mg/kg, and for nicotine 0.000120 mg/kg. Thirty samples of 5 chocolate brands with varying cocoa contents (30% to 99%) were analyzed in triplicate. Caffeine and nicotine were detected in all samples of chocolate, whereas myosmine was not present in any sample. The caffeine content ranged from 420 to 2780 mg/kg (relative standard deviation 0.1 to 11.5%) and nicotine from 0.000230 to 0.001590 mg/kg (RSD 2.0 to 22.1%). Practical Application We worked out a method for simultaneous determination of the alkaloids caffeine, myosmine and nicotine in the complex matrix chocolate using modern sample preparation and chromatographic techniques. This method allows the determination of the bioactive compounds in spite of the strongly different ranges for caffeine (420 to 2780 mg/kg) and for myosmine (below limit of detection) and nicotine (0.000230 to 0.001590 mg/kg). The content of caffeine and of the hitherto undetected nicotine correlated with the content of cocoa (30 to 99%) in the chocolate brands.
引用
收藏
页码:T251 / T255
页数:5
相关论文
共 50 条
  • [1] Simple determination of fluoride in biological samples by headspace solid-phase microextraction and gas chromatography-tandem mass spectrometry
    Kwon, Sun-Myung
    Shin, Ho-Sang
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1407 : 216 - 221
  • [2] Determination of fourteen UV filters in bathing water by headspace solid-phase microextraction and gas chromatography-tandem mass spectrometry
    Vila, Marlene
    Celeiro, Maria
    Lamas, J. Pablo
    Dagnac, Thierry
    Llompart, Maria
    Garcia-Jares, Carmen
    ANALYTICAL METHODS, 2016, 8 (39) : 7069 - 7079
  • [3] Determination of Lactones in Wines by Headspace Solid-Phase Microextraction and Gas Chromatography Coupled with Mass Spectrometry
    Perez-Olivero, S. J.
    Perez-Pont, M. L.
    Conde, J. E.
    Perez-Trujillo, J. P.
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2014, 2014
  • [4] Determination of acrolein by headspace solid-phase microextraction gas chromatography and mass spectrometry
    Takamoto, S
    Sakura, N
    Yashiki, M
    Kojima, T
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 758 (01): : 123 - 128
  • [5] Pesticide residue analysis in waters by solid-phase microextraction coupled to gas chromatography-tandem mass spectrometry
    Arrebola, FJ
    Aguado, SC
    Sánchez-Morito, N
    Frenich, AG
    Vidal, JLM
    ANALYTICAL LETTERS, 2004, 37 (01) : 99 - 117
  • [6] Quantification of Seven Terpenes in Human Serum by Headspace Solid-Phase Microextraction-Gas Chromatography-Tandem Mass Spectrometry
    Silva, Lalith K.
    Espenship, Michael F.
    Newman, Cody A.
    Blount, Benjamin C.
    De Jesus, Victor R.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2020, 54 (21) : 13861 - 13867
  • [7] Headspace Solid-Phase Microextraction Coupled with Gas Chromatography–Mass Spectrometry for the Determination of Volatile Organic Compounds in Urine
    Małgorzata Natalia Drabińska
    Urszula Starowicz
    Journal of Analytical Chemistry, 2020, 75 : 792 - 801
  • [8] Headspace Solid-Phase Microextraction Coupled with Gas Chromatography Mass Spectrometry for the Characterization of Polymeric Materials
    Kusch, Peter
    LC GC NORTH AMERICA, 2018, 36 (01) : 52 - 61
  • [9] Headspace solid-phase microextraction gas chromatography tandem mass spectrometry for the determination of brominated flame retardants in environmental solid samples
    Salgado-Petinal, Carmen
    Garcia-Chao, Maria
    Llompart, Maria
    Garcia-Jares, Carmen
    Cela, Rafael
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (03) : 637 - 644
  • [10] Headspace solid-phase microextraction gas chromatography tandem mass spectrometry for the determination of brominated flame retardants in environmental solid samples
    Carmen Salgado-Petinal
    Maria Garcia-Chao
    Maria Llompart
    Carmen Garcia-Jares
    Rafael Cela
    Analytical and Bioanalytical Chemistry, 2006, 385 : 637 - 644