Comparison of EAP thresholds with MAP levels in the nucleus 24 cochlear implant: Data from children

被引:138
|
作者
Hughes, ML
Brown, CJ
Abbas, PJ
Wolaver, AA
Gervais, JP
机构
[1] Univ Iowa, Dept Otolaryngol Head & Neck Surg, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Speech Pathol & Audiol, Iowa City, IA 52242 USA
来源
EAR AND HEARING | 2000年 / 21卷 / 02期
关键词
D O I
10.1097/00003446-200004000-00010
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objective: The purpose of this study is to examine the relationship between the electrically evoked compound action potential (EAP) thresholds and the MAP thresholds (T-levels) and maximum comfort levels (C-levels) in children implanted with the Nucleus 24 device. Design: EAP thresholds were measured using the Neural Response Telemetry system of the Nucleus 24 device. Twenty children implanted with the Nucleus 24 cochlear implant participated in this study. EAP thresholds were compared with the behavioral measures of T- and C-level used to construct the MAP these children used on a daily basis. For these subjects, both EAP and MAP T- and C-levels were obtained the same visit, which occurred at 3 to 5 mo postconnection. Results: EAP thresholds were shown to fall between MAP T- and C-level for 18 of 20 subjects tested; however, considerable variability across subjects was noted. On average, EAP thresholds fell at 53% of the MAP dynamic range. Correlations between EAP threshold and MAP T- and C-level improved substantially when combined with behavioral measures obtained from one electrode in the array. Conclusions: Moderate correlations were found between EAP thresholds and MAP T- and C-levels for the children participating in this study. However, a technique is described for improving the accuracy of predictions of MAP T- and C-levels based on EAP data combined with a small amount of behavioral information.
引用
收藏
页码:164 / 174
页数:11
相关论文
共 50 条
  • [41] The influence of stimulation levels on auditory thresholds and speech recognition in adult cochlear implant users
    Chaves Martins, Kelly Vasconcelos
    Schmidt Goffi-Gomez, Maria Valeria
    COCHLEAR IMPLANTS INTERNATIONAL, 2021, 22 (01) : 42 - 48
  • [42] Residual hearing conservation and electroacoustic stimulation with the nucleus 24 contour advance cochlear implant
    Fraysse, Bernard
    Macias, Angel Ramos
    Sterkers, Olivier
    Burdo, Sandro
    Ramsden, Richard
    Deguine, Olivier
    Klenzner, Thomas
    Lenarz, Thomas
    Rodriguez, Manuel Manrique
    Von Wallenberg, Ernst
    James, Chris
    OTOLOGY & NEUROTOLOGY, 2006, 27 (05) : 624 - 633
  • [43] Intra- and postoperative electrode impedance of the straight and Contour arrays of the Nucleus 24 cochlear implant: Relation to T and C levels
    van Wermeskerken, Gijs K. A.
    van Olphen, Adriaan F.
    Smoorenburg, Guido F.
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2006, 45 (09) : 537 - 544
  • [44] Changes in stimulation levels over time in nucleus 22 cochlear implant users
    Butts, SL
    Hodges, AV
    Dolan-Ash, S
    Balkany, TJ
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2000, 109 (12): : 53 - 56
  • [45] Comparison of ECAP threshold with T and C levels in children after Nucleus 24 implantation
    Wu, JL
    Huang, CY
    Lee, HH
    Kao, CC
    COCHLEAR IMPLANTS - AN UPDATE, 2002, : 111 - 115
  • [46] Multicenter evaluations of speech perception in adults and children with the Nucleus (Cochlear) 22-channel cochlear implant
    Clark, GM
    Dowell, RC
    Cowan, RS
    Pyman, BC
    Webb, RL
    TRANSPLANTS AND IMPLANTS IN OTOLOGY - III, PROCEEDINGS, 1996, : 353 - 363
  • [47] AutoNRT™:: An automated system that measures ECAP thresholds with the Nucleus® Freedom™ cochlear implant via machine intelligence
    Botros, Andrew
    van Dijk, Bas
    Killian, Matthijs
    ARTIFICIAL INTELLIGENCE IN MEDICINE, 2007, 40 (01) : 15 - 28
  • [48] SCOPE AND DESIGN OF THE CLINICAL-TRIAL OF THE NUCLEUS MULTICHANNEL COCHLEAR IMPLANT IN CHILDREN
    MECKLENBURG, DJ
    DEMOREST, ME
    STALLER, SJ
    EAR AND HEARING, 1991, 12 (04): : S10 - S14
  • [49] INITIAL EXPERIENCE WITH CHILDREN USING THE NUCLEUS-22 CHANNEL COCHLEAR IMPLANT
    ROBERTS, SA
    BUSBY, PA
    DOWELL, RC
    CLARK, GM
    TONG, YC
    MECKLENBURG, DJ
    SCANDINAVIAN AUDIOLOGY, 1988, : 115 - 119
  • [50] Some experiences with the Nucleus 20+2 cochlear implant in adults and children
    Linde, G
    Bredberg, G
    Lindstrom, B
    AMERICAN JOURNAL OF OTOLOGY, 1997, 18 (06): : S149 - S150