Comparison of EAP thresholds with MAP levels in the nucleus 24 cochlear implant: Data from children

被引:138
|
作者
Hughes, ML
Brown, CJ
Abbas, PJ
Wolaver, AA
Gervais, JP
机构
[1] Univ Iowa, Dept Otolaryngol Head & Neck Surg, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Speech Pathol & Audiol, Iowa City, IA 52242 USA
来源
EAR AND HEARING | 2000年 / 21卷 / 02期
关键词
D O I
10.1097/00003446-200004000-00010
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objective: The purpose of this study is to examine the relationship between the electrically evoked compound action potential (EAP) thresholds and the MAP thresholds (T-levels) and maximum comfort levels (C-levels) in children implanted with the Nucleus 24 device. Design: EAP thresholds were measured using the Neural Response Telemetry system of the Nucleus 24 device. Twenty children implanted with the Nucleus 24 cochlear implant participated in this study. EAP thresholds were compared with the behavioral measures of T- and C-level used to construct the MAP these children used on a daily basis. For these subjects, both EAP and MAP T- and C-levels were obtained the same visit, which occurred at 3 to 5 mo postconnection. Results: EAP thresholds were shown to fall between MAP T- and C-level for 18 of 20 subjects tested; however, considerable variability across subjects was noted. On average, EAP thresholds fell at 53% of the MAP dynamic range. Correlations between EAP threshold and MAP T- and C-level improved substantially when combined with behavioral measures obtained from one electrode in the array. Conclusions: Moderate correlations were found between EAP thresholds and MAP T- and C-levels for the children participating in this study. However, a technique is described for improving the accuracy of predictions of MAP T- and C-levels based on EAP data combined with a small amount of behavioral information.
引用
收藏
页码:164 / 174
页数:11
相关论文
共 50 条
  • [1] Examination of EAP thresholds (NRT thresholds) during Nucleus 24 cochlear implant operations
    Kawano, A
    Shimizu, A
    Hagiwara, A
    Fujita, H
    Tomizawa, A
    Wakasa, E
    Suzuki, M
    Ueda, I
    Konno, N
    Iwasaki, J
    COCHLEAR IMPLANTS - AN UPDATE, 2002, : 59 - 68
  • [2] Speech Perception and Audiometry Thresholds in Nucleus Cochlear 22 and Nucleus 24 Implant Users
    Samuel, Paola Angelica
    Schmidt Goffi Gomez, Maria Valeria
    Befi Lopes, Debora Maria
    Matas, Carla Gentile
    Tsuji, Robinson Koji
    de Brito Neto, Rubens Vuono
    Bento, Ricardo Ferreira
    INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2010, 14 (03) : 331 - 337
  • [3] COMPARISON OF PROCEDURES FOR OBTAINING THRESHOLDS AND MAXIMUM ACCEPTABLE LOUDNESS LEVELS WITH THE NUCLEUS COCHLEAR IMPLANT SYSTEM
    SKINNER, MW
    HOLDEN, LK
    HOLDEN, TA
    DEMOREST, ME
    JOURNAL OF SPEECH AND HEARING RESEARCH, 1995, 38 (03): : 677 - 689
  • [4] The relationship between EAP and EABR thresholds and levels used to program the nucleus 24 speech processor: Data from adults
    Brown, CJ
    Hughes, ML
    Luk, B
    Abbas, PJ
    Wolaver, A
    Gervais, J
    EAR AND HEARING, 2000, 21 (02): : 151 - 163
  • [5] From Nucleus 24 to 513: Changing Cochlear Implant Design Affects Auditory Response Thresholds
    Gordon, Karen A.
    Papsin, Blake C.
    OTOLOGY & NEUROTOLOGY, 2013, 34 (03) : 436 - 442
  • [6] Within-subject comparison between NRT predicted MAP and behaviorally measured MAP in Nucleus 24 cochlear implant children using the ACE strategy
    Huang, TS
    Hsu, HC
    Chen, TM
    Wang, CY
    COCHLEAR IMPLANTS - AN UPDATE, 2002, : 125 - 129
  • [7] Comparison of speech perception performance between the Nucleus 24 and Nucleus 24 Contour cochlear implant systems
    Bacciu, A
    Pasanisi, E
    Vincenti, V
    Guida, M
    Barbot, A
    Berghenti, M
    Forli, F
    Berrettini, S
    Bacciu, S
    ACTA OTO-LARYNGOLOGICA, 2004, 124 (10) : 1155 - 1158
  • [8] Comparison of Pure-Tone Thresholds and Cochlear Microphonics Thresholds in Pediatric Cochlear Implant Patients
    Coulthurst, Sarah
    Nachman, Alison J.
    Murray, Mike T.
    Koka, Kanthaiah
    Saoji, Aniket A.
    EAR AND HEARING, 2020, 41 (05): : 1320 - 1326
  • [9] STAPEDIUS REFLEX AND EABR THRESHOLDS IN EXPERIENCED USERS OF THE NUCLEUS COCHLEAR IMPLANT
    VANDENBORNE, B
    MENS, LHM
    SNIK, AFM
    SPIES, TH
    VANDENBROEK, P
    ACTA OTO-LARYNGOLOGICA, 1994, 114 (02) : 141 - 143
  • [10] Surgical issues in exchanging a nucleus CI22M cochlear implant for a nucleus CI24M cochlear implant
    Gibson, WPR
    COCHLEAR IMPLANTS - AN UPDATE, 2002, : 219 - 222