The difference of detecting water mist and smoke by electromagnetic wave in simulation experiments

被引:0
|
作者
Zhang, Jingdi [1 ]
Cui, Bing [1 ]
Xiao, Si [1 ]
机构
[1] Cent S Univ, Inst Super Microstruct & Ultrafast Proc Adv Mat, Sch Phys & Elect, Hunan Key Lab Super Microstruct & Ultrafast Proc, Changsha 410083, Peoples R China
关键词
water mist and smoke; Ansoft HFSS; forest fire;
D O I
10.1117/12.2197991
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Although mist is similar to smoke in morphology, their compositions are very different. Therefore there is a significant difference between mist and smoke when detected by electromagnetic wave. This paper puts forward a kind of feasible solution based on Ansoft HFSS software about how to determine the forest fire by distinguishing mist and smoke above the forest. The experiments simulate the difference between mist and smoke model when detected by electromagnetic wave in different wavelengths. We find the mist and smoke model cannot absorb or reflect electromagnetic wave efficiently in Megahertz band. While in Gigahertz band, mist model began to absorb and reflect electromagnetic wave above 650 Gigahertz band, but no change in smoke model. And the biggest difference appears in Terahertz band.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Estimation of the effects of water mist system on the tunnel critical velocity due to smoke cooling
    Deng, Tao
    Norris, Stuart
    Sharma, Rajnish N.
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2022, 120
  • [32] Numerical studies on the smoke control by water mist screens with transverse ventilation in tunnel fires
    Liang, Qiang
    Li, Yangfeng
    Li, Junmei
    Xu, Hui
    Li, Kaiyuan
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2017, 64 : 177 - 183
  • [33] Experimental research on properties of smoke blocked by water mist screen in a long narrow channel
    Liang Q.
    Li Y.
    Li J.
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2017, 38 (11): : 1751 - 1756
  • [34] Study on numerical simulation of water mist suppression in tunnel fires
    Zhu Wei
    Wang Tong
    You Fei
    Jin Longzhe
    PROGRESS IN MINING SCIENCE AND SAFETY TECHNOLOGY, PTS A AND B, 2007, : 1884 - 1889
  • [35] Investigation on the smoke stratification stability behaviors in tunnel fires under water mist system
    Jia, Zhuo
    Wei, Xiaocui
    Gao, Zihe
    Wang, Pu
    Cai, Jiajun
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2025,
  • [36] The combined effect of a water mist system and longitudinal ventilation on the fire and smoke dynamics in a tunnel
    Liu, Yuanjun
    Fang, Zheng
    Tang, Zhi
    Beji, Tarek
    Merci, Bart
    FIRE SAFETY JOURNAL, 2021, 122
  • [37] Numerical simulation of deep-water wave breaking using RANS: Comparison with experiments
    Liu, Yuxuan
    van den Bremer, Ton S.
    Adcock, Thomas A. A.
    EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2024, 108 : 211 - 225
  • [38] Simulation Study on Suppressing Shielded Fires by Water Mist Systems
    Hamzehpour, Azad
    Verda, Vittorio
    Borchiellini, Romano
    FIRE-SWITZERLAND, 2023, 6 (04):
  • [39] Suppression on the tunnel fire by coupling the longitudinal smoke discharge and high pressure water mist
    Zhang, P.-H. (zhangpeihong@mail.neu.edu.cn), 2013, Northeast University (34):
  • [40] Research on the application mechanism of water mist curtain smoke blocking and heat blocking in tunnels
    Zhong, Wei
    Zhang, Zhanming
    Wu, Yinghao
    Gao, Zihe
    INDOOR AND BUILT ENVIRONMENT, 2025, 34 (02) : 330 - 354