Colorectal cancer staging: comparison of whole-body PET/CT and PET/MR

被引:41
|
作者
Catalano, Onofrio A. [1 ,2 ]
Coutinho, Artur M. [3 ,4 ]
Sahani, Dushyant V. [2 ]
Vangel, Mark G. [5 ,6 ]
Gee, Michael S. [2 ,7 ]
Hahn, Peter F. [2 ]
Witzel, Thomas [1 ]
Soricelli, Andrea [8 ]
Salvatore, Marco [9 ]
Catana, Ciprian [1 ]
Mahmood, Umar [1 ,10 ]
Rosen, Bruce R. [1 ]
Gervais, Debra [2 ]
机构
[1] Harvard Univ, Dept Radiol, Athinoula A Martinos Ctr Biomed Imaging, Massachusetts Gen Hosp,Med Sch, 149 Thirteenth St, Charlestown, MA 02129 USA
[2] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Abdominal Imaging, WHT 270,55 Fruit St, Boston, MA 02114 USA
[3] Univ Sao Paulo, Med Sch FMUSP, Dept Nucl Med, BR-01308050 Sao Paulo, Brazil
[4] Hosp Sirio Libanes, BR-01308050 Sao Paulo, Brazil
[5] Harvard Univ, MGH Biostat Ctr, Dept Radiol, Med Sch, 149 Thirteenth St, Charlestown, MA 02129 USA
[6] Harvard Univ, MGH Martinos Ctr, Med Sch, 149 Thirteenth St, Charlestown, MA 02129 USA
[7] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Pediat Imaging, 55 Fruit St, Boston, MA 02114 USA
[8] Univ Naples Parthenope, Dept Radiol, Via F Acton 38, I-80143 Naples, Italy
[9] SDN IRCCS, Dept Nucl Med, Via Gianturco 113, I-80143 Naples, Italy
[10] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Nucl Med, 55 Fruit St, Boston, MA 02114 USA
关键词
PET/MR; Colorectal cancer; Staging; PET/CT; Whole-body staging; DUAL-TIME-POINT; LIVER METASTASES; FDG-PET; DIAGNOSTIC-ACCURACY; RECTAL-CANCER; F-18-FDG PET; CT; MRI; PERFORMANCE; RECURRENCE;
D O I
10.1007/s00261-016-0985-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Correct staging is imperative for colorectal cancer (CRC) since it influences both prognosis and management. Several imaging methods are used for this purpose, with variable performance. Positron emission tomography-magnetic resonance (PET/MR) is an innovative imaging technique recently employed for clinical application. The present study was undertaken to compare the staging accuracy of whole-body positron emission tomography-computed tomography (PET/CT) with whole-body PET/MR in patients with both newly diagnosed and treated colorectal cancer. Methods: Twenty-six patients, who underwent same day whole-body (WB) PET/CT and WB-PET/MR, were evaluated. PET/CT and PET/MR studies were interpreted by consensus by a radiologist and a nuclear medicine physician. Correlations with prior imaging and follow-up studies were used as the reference standard. Correct staging was compared between methods using McNemar's Chi square test. Results: The two methods were in agreement and correct for 18/26 (69%) patients, and in agreement and incorrect for one patient (3.8%). PET/MR and PET/CT stages for the remaining 7/26 patients (27%) were discordant, with PET/MR staging being correct in all seven cases. PET/MR significantly outperformed PET/CT overall for accurate staging (P = 0.02). Conclusion: PET/MR outperformed PET/CT in CRC staging. PET/MR might allow accurate local and distant staging of CRC patients during both at the time of diagnosis and during follow-up.
引用
收藏
页码:1141 / 1151
页数:11
相关论文
共 50 条
  • [41] Three-way Comparison of Whole-Body MR, Coregistered Whole-Body FDG PET/MR, and Integrated Whole-Body FDG PET/CT Imaging: TNM and Stage Assessment Capability for Non-Small Cell Lung Cancer Patients
    Ohno, Yoshiharu
    Koyama, Hisanobu
    Yoshikawa, Takeshi
    Takenaka, Daisuke
    Seki, Shinichiro
    Yui, Masao
    Yamagata, Hitoshi
    Aoyagi, Kota
    Matsumoto, Sumiaki
    Sugimura, Kazuro
    RADIOLOGY, 2015, 275 (03) : 849 - 861
  • [42] Whole-body Doses to Technologists Working with PET and PET/CT
    Svalling, S.
    Jorgensen, H.
    Holm, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S290 - S290
  • [43] Intraindividual comparison of subsequently performed PET/MRI to PET/CT for whole-body staging: Results of a unicenter trial in 1000 patients
    Martin, O.
    Kirchner, J.
    Buchbender, C.
    Antoch, G.
    Herrmann, K.
    Suntharalingam, S.
    Forsting, M.
    Umutlu, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S210 - S211
  • [44] Implementation of FAST-PET/MRI for whole-body staging of female patients with recurrent pelvic malignancies: A comparison to PET/CT
    Grueneisen, Johannes
    Schaarschmidt, Benedikt Michael
    Heubner, Martin
    Suntharalingam, Saravanabavaan
    Milk, Ines
    Kinner, Sonja
    Heubner, Antonia
    Forsting, Michael
    Lauenstein, Thomas
    Ruhlmann, Verena
    Umutlu, Lale
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (11) : 2097 - 2102
  • [45] Staging performance of whole-body DWI, PET/CT and PET/MRI in invasive ductal carcinoma of the breast
    Catalano, Onofrio Antonio
    Daye, Dania
    Signore, Alberto
    Iannace, Carlo
    Vangel, Mark
    Luongo, Angelo
    Catalano, Marco
    Filomena, Mazzeo
    Mansi, Luigi
    Soricelli, Andrea
    Salvatore, Marco
    Fuin, Niccolo
    Catana, Ciprian
    Mahmood, Umar
    Rosen, Bruce Robert
    INTERNATIONAL JOURNAL OF ONCOLOGY, 2017, 51 (01) : 281 - 288
  • [46] 18F-FDG PET/CT of Patients With Cancer: Comparison of Whole-Body and Limited Whole-Body Technique
    Osman, Medhat M.
    Chaar, Bassem T.
    Muzaffar, Razi
    Oliver, Dana
    Reimers, Hans Joachim
    Walz, Bruce
    Nguyen, Nghi C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) : 1397 - 1403
  • [47] Staging and Prognosis in Patients With Breast Cancer by Means of MR-Mammography, Mammoscintigraphy and Whole-Body PET
    Sukhov, V. Y.
    Demshina, T. E.
    Zaplatnikov, K. L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S352 - S352
  • [48] Accuracy of whole-body FDG-PET/CT for tumor staging in oncology
    Antoch, G
    Saoudi, N
    Freudenberg, LS
    Kuehl, H
    Mueller, SP
    Beyer, T
    Bockisch, A
    Debatin, JF
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S285 - S285
  • [49] Cost considerations for whole-body MRI and PET/CT as part of oncologic staging
    Plathow, C.
    Walz, M.
    Lichy, M. P.
    Aschoff, P.
    Pfannenberg, C.
    Bock, H.
    Eschmann, S. M.
    Claussen, C. D.
    Schlemmer, H. P.
    RADIOLOGE, 2008, 48 (04): : 384 - 396
  • [50] Relative value of three whole-body MR approaches for PET-MR, including gadofosveset-enhanced MR, in comparison to PET-CT
    Obara, Piotr
    Loening, Andreas
    Taviani, Valentina
    Iagaru, Andrei
    Hargreaves, Brian A.
    Vasanawala, Shreyas
    CLINICAL IMAGING, 2018, 48 : 62 - 68