Colorectal cancer staging: comparison of whole-body PET/CT and PET/MR

被引:42
|
作者
Catalano, Onofrio A. [1 ,2 ]
Coutinho, Artur M. [3 ,4 ]
Sahani, Dushyant V. [2 ]
Vangel, Mark G. [5 ,6 ]
Gee, Michael S. [2 ,7 ]
Hahn, Peter F. [2 ]
Witzel, Thomas [1 ]
Soricelli, Andrea [8 ]
Salvatore, Marco [9 ]
Catana, Ciprian [1 ]
Mahmood, Umar [1 ,10 ]
Rosen, Bruce R. [1 ]
Gervais, Debra [2 ]
机构
[1] Harvard Univ, Dept Radiol, Athinoula A Martinos Ctr Biomed Imaging, Massachusetts Gen Hosp,Med Sch, 149 Thirteenth St, Charlestown, MA 02129 USA
[2] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Abdominal Imaging, WHT 270,55 Fruit St, Boston, MA 02114 USA
[3] Univ Sao Paulo, Med Sch FMUSP, Dept Nucl Med, BR-01308050 Sao Paulo, Brazil
[4] Hosp Sirio Libanes, BR-01308050 Sao Paulo, Brazil
[5] Harvard Univ, MGH Biostat Ctr, Dept Radiol, Med Sch, 149 Thirteenth St, Charlestown, MA 02129 USA
[6] Harvard Univ, MGH Martinos Ctr, Med Sch, 149 Thirteenth St, Charlestown, MA 02129 USA
[7] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Pediat Imaging, 55 Fruit St, Boston, MA 02114 USA
[8] Univ Naples Parthenope, Dept Radiol, Via F Acton 38, I-80143 Naples, Italy
[9] SDN IRCCS, Dept Nucl Med, Via Gianturco 113, I-80143 Naples, Italy
[10] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Nucl Med, 55 Fruit St, Boston, MA 02114 USA
关键词
PET/MR; Colorectal cancer; Staging; PET/CT; Whole-body staging; DUAL-TIME-POINT; LIVER METASTASES; FDG-PET; DIAGNOSTIC-ACCURACY; RECTAL-CANCER; F-18-FDG PET; CT; MRI; PERFORMANCE; RECURRENCE;
D O I
10.1007/s00261-016-0985-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Correct staging is imperative for colorectal cancer (CRC) since it influences both prognosis and management. Several imaging methods are used for this purpose, with variable performance. Positron emission tomography-magnetic resonance (PET/MR) is an innovative imaging technique recently employed for clinical application. The present study was undertaken to compare the staging accuracy of whole-body positron emission tomography-computed tomography (PET/CT) with whole-body PET/MR in patients with both newly diagnosed and treated colorectal cancer. Methods: Twenty-six patients, who underwent same day whole-body (WB) PET/CT and WB-PET/MR, were evaluated. PET/CT and PET/MR studies were interpreted by consensus by a radiologist and a nuclear medicine physician. Correlations with prior imaging and follow-up studies were used as the reference standard. Correct staging was compared between methods using McNemar's Chi square test. Results: The two methods were in agreement and correct for 18/26 (69%) patients, and in agreement and incorrect for one patient (3.8%). PET/MR and PET/CT stages for the remaining 7/26 patients (27%) were discordant, with PET/MR staging being correct in all seven cases. PET/MR significantly outperformed PET/CT overall for accurate staging (P = 0.02). Conclusion: PET/MR outperformed PET/CT in CRC staging. PET/MR might allow accurate local and distant staging of CRC patients during both at the time of diagnosis and during follow-up.
引用
收藏
页码:1141 / 1151
页数:11
相关论文
共 50 条
  • [21] Whole-body PET/CT-mammography for staging breast cancer: initial results
    Heusner, T-A
    Freudenberg, L. S.
    Kuehl, H.
    Hauth, E. A. M.
    Veit-Haibach, P.
    Forsting, M.
    Bockisch, A.
    Antoch, G.
    BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (969): : 743 - 748
  • [22] First Clinical Experience with Integrated Whole-Body PET/MR: Comparison to PET/CT in Patients with Oncologic Diagnoses
    Drzezga, Alexander
    Souvatzoglou, Michael
    Eiber, Matthias
    Beer, Ambros J.
    Fuerst, Sebastian
    Martinez-Moeller, Axel
    Nekolla, Stephan G.
    Ziegler, Sibylle
    Ganter, Carl
    Rummeny, Ernst J.
    Schwaiger, Markus
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (06) : 845 - 855
  • [23] Whole-body PET angiography on semiconductor PET/CT
    Norikane, Takashi
    Yamamoto, Yuka
    Takami, Yasukage
    Mitamura, Katsuya
    Matsumoto, Keisuke
    Maeda, Yukito
    Yamashita, Yoichi
    Nishiyama, Yoshihiro
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (02) : 885 - 888
  • [24] Whole-body PET angiography on semiconductor PET/CT
    Takashi Norikane
    Yuka Yamamoto
    Yasukage Takami
    Katsuya Mitamura
    Keisuke Matsumoto
    Yukito Maeda
    Yoichi Yamashita
    Yoshihiro Nishiyama
    Journal of Nuclear Cardiology, 2022, 29 : 885 - 888
  • [25] Comparison of lesion detectability of dedicated breast PET and whole-body PET/CT
    Hanaoka, Kohei
    Watanabe, Shota
    Morimoto-Ishikawa, Daisuke
    Ueno, Naomi
    Ohtani, Atsushi
    Yamakawa, Yoshiyuki
    Minagawa, Suzuka
    Takenouchi, Shiho
    Mizuta, Tetsuro
    Kaida, Hayato
    Itoh, Toshikazu
    Komoike, Yoshifumi
    Ishii, Kazunari
    JOURNAL OF NUCLEAR MEDICINE, 2022, 63
  • [26] Whole-body tumor staging: MRI or FDG-PET/CT?
    Antoch, G
    Vogt, FM
    Bockisch, A
    Ruehm, SG
    RADIOLOGE, 2004, 44 (09): : 882 - 888
  • [27] Whole-body dual-modality PET/CT and whole-body MRI for tumor staging in oncology
    Antoch, G
    Vogt, FM
    Freudenberg, LS
    Nazaradeh, F
    Goehde, SC
    Barkhausen, J
    Dahmen, G
    Bockisch, A
    Debatin, JF
    Ruehm, SG
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2003, 290 (24): : 3199 - 3206
  • [28] Side by side comparison of integrated whole-body PET/MR with PET/CT in prostate cancer: a systematic review and meta-analysis
    Salavati, Ali
    Gencturk, Mehmet
    Froelich, Jerry
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [29] Small Cell Lung Cancer Staging: Prospective Comparison of Conventional Staging Tests, FDG PET/CT, Whole-Body MRI, and Coregistered FDG PET/MRI
    Ohno, Yoshiharu
    Yoshikawa, Takeshi
    Takenaka, Daisuke
    Koyama, Hisanobu
    Aoyagi, Kota
    Yui, Masao
    Oshima, Yuka
    Hamabuchi, Nayu
    Tanaka, Yumi
    Shigemura, Chika
    Oota, Seiichiro
    Nomura, Masahiko
    Murayama, Kazuhiro
    Inui, Yoshitaka
    Kikukawa, Kaoru
    Toyama, Hiroshi
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (05) : 899 - 908
  • [30] Staging of colon cancer: whole-body MRI vs. whole-body PET-CT-initial clinical experience
    Squillaci, Ettore
    Manenti, Guglielmo
    Mancino, Stefano
    Ciccio, Carmelo
    Calabria, Ferdinando
    Danieli, Roberta
    Schillaci, Orazio
    Simonetti, Giovanni
    ABDOMINAL IMAGING, 2008, 33 (06): : 676 - 688