Microbubble Composition and Preparation for High-Frequency Contrast-Enhanced Ultrasound Imaging: In Vitro and In Vivo Evaluation

被引:27
|
作者
Daeichin, Verya [1 ,4 ,5 ]
van Rooij, Tom [1 ]
Skachkov, Ilya [1 ,2 ]
Ergin, Bulent [7 ]
Specht, Patricia A. C. [8 ]
Lima, Alexandre [6 ]
Ince, Can [6 ,7 ]
Bosch, Johan G. [1 ]
van der Steen, Antonius F. W. [1 ,3 ,4 ]
de Jong, Nico [1 ,4 ,5 ]
Kooiman, Klazina [1 ]
机构
[1] Erasmus MC, Ctr Thorax, Dept Biomed Engn, NL-3000 CA Rotterdam, Netherlands
[2] Univ Med Ctr Utrecht, Imaging Div, NL-3508 GA Utrecht, Netherlands
[3] Shenzhen Inst Adv Technol, Shenzhen 518000, Peoples R China
[4] Delft Univ Technol, Lab Acoust Wavefield Imaging, Fac Sci Appl, NL-2628 CJ Delft, Netherlands
[5] Netherlands Heart Inst, NL-3511 EP Utrecht, Netherlands
[6] Erasmus MC, Dept Intens Care Adults, NL-3000 CA Rotterdam, Netherlands
[7] Acad Med Ctr, Dept Translat Physiol, NL-1100 DD Amsterdam, Netherlands
[8] Erasmus MC, Dept Anesthesiol, Lab Expt Anesthesiol, NL-3000 CA Rotterdam, Netherlands
关键词
Contrast agent; contrast-enhanced ultrasound (CEUS) imaging; high-frequency; in vitro; in vivo; microbubble; LIPID-COATED MICROBUBBLES; PHOSPHOLIPID ENCAPSULATED MICROBUBBLES; MICRO-ULTRASOUND; VISCOELASTIC PROPERTIES; TARGETED MICROBUBBLES; SUBHARMONIC RESPONSE; TUMOR ANGIOGENESIS; AGENTS; BEHAVIOR; SIZE;
D O I
10.1109/TUFFC.2016.2640342
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Although high-frequency ultrasound imaging is gaining attention in various applications, hardly any ultrasound contrast agents (UCAs) dedicated to such frequencies (>15 MHz) are available for contrast-enhanced ultrasound (CEUS) imaging. Moreover, the composition of the limited commercially available UCAs for high-frequency CEUS (hfCEUS) is largely unknown, while shell properties have been shown to be an important factor for their performance. The aim of our study was to produce UCAs in-house for hfCEUS. Twelve different UCA formulations A-L were made by either sonication or mechanical agitation. The gas core consisted of C4F10 and the main coating lipid was either 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC; A-F formulation) or 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC; G-L formulation). Mechanical agitation resulted in UCAs with smaller microbubbles (number weighted mean diameter similar to 1 mu m) than sonication (number weighted mean diameter similar to 2 mu m). UCA formulations with similar size distributions but different main lipid components showed that the DPPC-based UCA formulations had higher nonlinear responses at both the fundamental and subharmonic frequencies in vitro for hfCEUS using the Vevo2100 high-frequency preclinical scanner (FUJIFILM VisualSonics, Inc.). In addition, UCA formulations F (DSPC-based) and L (DPPC-based) that were made by mechanical agitation performed similar in vitro to the commercially available TargetReady MicroMarker (FUJIFILM VisualSonics, Inc.). UCA formulation F also performed similar to Target-Ready MicroMarker in vivo in pigs with similar mean contrast intensity within the kidney (n = 7), but formulation L did not. This is likely due to the lower stability of formulation L in vivo. Our study shows that DSPC-based microbubbles produced by mechanical agitation resulted in small microbubbles with high nonlinear responses suitable for hfCEUS imaging.
引用
收藏
页码:555 / 567
页数:13
相关论文
共 50 条
  • [41] OPTIMIZING SENSITIVITY OF ULTRASOUND CONTRAST-ENHANCED SUPER-RESOLUTION IMAGING BY TAILORING SIZE DISTRIBUTION OF MICROBUBBLE CONTRAST AGENT
    Lin, Fanglue
    Tsuruta, James K.
    Rojas, Juan D.
    Dayton, Paul A.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (10): : 2488 - 2493
  • [42] In vivo adaptive focusing for clinical contrast-enhanced transcranial ultrasound imaging in human
    Robin, Justine
    Demene, Charlie
    Heiles, Baptiste
    Blanvillain, Victor
    Puke, Liene
    Perren, Fabienne
    Tanter, Mickael
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (02):
  • [43] Evaluation of renal microperfusion in hyperuricemic nephropathy by contrast-enhanced ultrasound imaging
    He, Li
    Li, Ze
    Zhang, Qunzi
    Chen, Yini
    Gao, Yihui
    Chen, Teng
    Wang, Niansong
    Jiang, Lixin
    Fan, Ying
    [J]. DISEASE MODELS & MECHANISMS, 2022, 15 (07)
  • [44] Contrast-enhanced ultrasound imaging using long-circulating cationic magnetic microbubbles in vitro and in vivo validations
    Liu, Yingying
    Lai, Xiaoshu
    Zhu, Yao
    Guo, Fengjuan
    Su, Lili
    Arkin, Gulzira
    He, Tianzhen
    Xu, Jinfeng
    Ran, Haitao
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2022, 616
  • [45] The use of high-frequency ultrasound imaging and biofluorescence for in vivo evaluation of gene therapy vectors
    Ingram, Nicola
    Macnab, Stuart A.
    Marston, Gemma
    Scott, Nigel
    Carr, Ian M.
    Markham, Alexander F.
    Whitehouse, Adrian
    Coletta, P. Louise
    [J]. BMC MEDICAL IMAGING, 2013, 13
  • [46] IMAGING MICROVASCULATURE WITH CONTRAST-ENHANCED ULTRAHARMONIC ULTRASOUND
    Maresca, David
    Skachkov, Ilya
    Renaud, Guillaume
    Jansen, Krista
    van Soest, Gijs
    de Jong, Nico
    van der Steen, Antonius F. W.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (06): : 1318 - 1328
  • [47] Imaging Microbubbles With Contrast-Enhanced Endobronchial Ultrasound
    Mcgrath, Sean
    Shen, Yu-Jack
    Aragaki, Masato
    Motooka, Yamato
    Koga, Takamasa
    Gregor, Alexander
    Bernards, Nicholas
    Cherin, Emmanuel
    Demore, Christine E. M.
    Yasufuku, Kazuhiro
    Matsuura, Naomi
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (01): : 28 - 38
  • [48] TRANSABDOMINAL CONTRAST-ENHANCED ULTRASOUND IMAGING OF THE PROSTATE
    Mischi, Massimo
    Demi, Libertario
    Smeenge, Martijn
    Kuenen, Maarten P. J.
    Postema, Arnoud W.
    de la Rosette, Jean J. M. C. H.
    Wijkstra, Hessel
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (04): : 1112 - 1118
  • [49] Contrast-enhanced ultrasound for molecular imaging of angiogenesis
    Eisenbrey, J. R.
    Forsberg, F.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S138 - S146
  • [50] Characteristics of high frame frequency contrast-enhanced ultrasound in renal tumors
    WeiPing Zhang
    JingLing Wang
    Li Chen
    [J]. BMC Medical Imaging, 24