Microbubble Composition and Preparation for High-Frequency Contrast-Enhanced Ultrasound Imaging: In Vitro and In Vivo Evaluation

被引:27
|
作者
Daeichin, Verya [1 ,4 ,5 ]
van Rooij, Tom [1 ]
Skachkov, Ilya [1 ,2 ]
Ergin, Bulent [7 ]
Specht, Patricia A. C. [8 ]
Lima, Alexandre [6 ]
Ince, Can [6 ,7 ]
Bosch, Johan G. [1 ]
van der Steen, Antonius F. W. [1 ,3 ,4 ]
de Jong, Nico [1 ,4 ,5 ]
Kooiman, Klazina [1 ]
机构
[1] Erasmus MC, Ctr Thorax, Dept Biomed Engn, NL-3000 CA Rotterdam, Netherlands
[2] Univ Med Ctr Utrecht, Imaging Div, NL-3508 GA Utrecht, Netherlands
[3] Shenzhen Inst Adv Technol, Shenzhen 518000, Peoples R China
[4] Delft Univ Technol, Lab Acoust Wavefield Imaging, Fac Sci Appl, NL-2628 CJ Delft, Netherlands
[5] Netherlands Heart Inst, NL-3511 EP Utrecht, Netherlands
[6] Erasmus MC, Dept Intens Care Adults, NL-3000 CA Rotterdam, Netherlands
[7] Acad Med Ctr, Dept Translat Physiol, NL-1100 DD Amsterdam, Netherlands
[8] Erasmus MC, Dept Anesthesiol, Lab Expt Anesthesiol, NL-3000 CA Rotterdam, Netherlands
关键词
Contrast agent; contrast-enhanced ultrasound (CEUS) imaging; high-frequency; in vitro; in vivo; microbubble; LIPID-COATED MICROBUBBLES; PHOSPHOLIPID ENCAPSULATED MICROBUBBLES; MICRO-ULTRASOUND; VISCOELASTIC PROPERTIES; TARGETED MICROBUBBLES; SUBHARMONIC RESPONSE; TUMOR ANGIOGENESIS; AGENTS; BEHAVIOR; SIZE;
D O I
10.1109/TUFFC.2016.2640342
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Although high-frequency ultrasound imaging is gaining attention in various applications, hardly any ultrasound contrast agents (UCAs) dedicated to such frequencies (>15 MHz) are available for contrast-enhanced ultrasound (CEUS) imaging. Moreover, the composition of the limited commercially available UCAs for high-frequency CEUS (hfCEUS) is largely unknown, while shell properties have been shown to be an important factor for their performance. The aim of our study was to produce UCAs in-house for hfCEUS. Twelve different UCA formulations A-L were made by either sonication or mechanical agitation. The gas core consisted of C4F10 and the main coating lipid was either 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC; A-F formulation) or 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC; G-L formulation). Mechanical agitation resulted in UCAs with smaller microbubbles (number weighted mean diameter similar to 1 mu m) than sonication (number weighted mean diameter similar to 2 mu m). UCA formulations with similar size distributions but different main lipid components showed that the DPPC-based UCA formulations had higher nonlinear responses at both the fundamental and subharmonic frequencies in vitro for hfCEUS using the Vevo2100 high-frequency preclinical scanner (FUJIFILM VisualSonics, Inc.). In addition, UCA formulations F (DSPC-based) and L (DPPC-based) that were made by mechanical agitation performed similar in vitro to the commercially available TargetReady MicroMarker (FUJIFILM VisualSonics, Inc.). UCA formulation F also performed similar to Target-Ready MicroMarker in vivo in pigs with similar mean contrast intensity within the kidney (n = 7), but formulation L did not. This is likely due to the lower stability of formulation L in vivo. Our study shows that DSPC-based microbubbles produced by mechanical agitation resulted in small microbubbles with high nonlinear responses suitable for hfCEUS imaging.
引用
收藏
页码:555 / 567
页数:13
相关论文
共 50 条
  • [31] The Preparation of Chicken Ex Ovo Embryos and Chorioallantoic Membrane Vessels as In Vivo Model for Contrast-Enhanced Ultrasound Imaging and Microbubble-Mediated Drug Delivery Studies
    Meijlink, Bram
    Skachkov, Ilya
    van der Steen, Antonius F. W.
    de Jong, Nico
    Kooiman, Klazina
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2021, (168): : 1 - 27
  • [32] Evaluation of contrast-enhanced color Doppler ultrasound for the quantification of angiogenesis in vivo
    Lassau, N
    Koscielny, S
    Opolon, P
    De Baere, T
    Peronneau, P
    Leclere, J
    Roche, A
    INVESTIGATIVE RADIOLOGY, 2001, 36 (01) : 50 - 55
  • [33] Evaluation of Uterine Fibroid Vascularity Using Contrast-Enhanced Ultrasound in Comparison with Contrast-Enhanced Magnetic Resonance Imaging
    Machado, Priscilla
    Tan, Allison
    Forsberg, Flemming
    Gonsalves, Carin F.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (03): : 394 - 398
  • [34] Three-dimensional evaluation of microvascular networks using contrast-enhanced ultrasound and microbubble tracking
    Johnson, Kenneth
    Oezdemir, Ipek
    Hoyt, Kenneth
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [35] Contrast Imaging in Mouse Embryos Using High-frequency Ultrasound
    Denbeigh, Janet M.
    Nixon, Brian A.
    Puri, Mira C.
    Foster, F. Stuart
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2015, (97):
  • [36] In Vitro Evaluation and Theoretical Modeling of the Dissolution Behavior of a Microbubble Contrast Agent for Ultrasound Imaging
    Conversano, Francesco
    Franchini, Roberto
    Lay-Ekuakille, Aime
    Casciaro, Sergio
    IEEE SENSORS JOURNAL, 2012, 12 (03) : 496 - 503
  • [37] Extracorporeal high-frequency combined with contrast-enhanced ultrasound: a novel imaging method for detection and treatment evaluation of patients with cervical trachea-associated relapsing polychondritis
    Tang, Jiaxing
    He, Weihua
    Zhang, Yuxin
    Tang, Qing
    He, Niantu
    Liang, Zechun
    Li, Shiyue
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (24)
  • [39] Evaluation of renal microperfusion in hyperuricemic nephropathy by contrast-enhanced ultrasound imaging
    He, Li
    Li, Ze
    Zhang, Qunzi
    Chen, Yini
    Gao, Yihui
    Chen, Teng
    Wang, Niansong
    Jiang, Lixin
    Fan, Ying
    DISEASE MODELS & MECHANISMS, 2022, 15 (07)
  • [40] In-vivo imaging of carotid plaque neoangiogenesis with contrast-enhanced harmonic ultrasound
    Papaioannou, Theodore G.
    Vavuranakis, Manolis
    Androulakis, Aristides
    Lazaros, George
    Kakadiaris, Ioannis
    Vlaseros, Ioannis
    Naghavi, Morteza
    Kallikazaros, Ioannis
    Stefanadis, Christodoulos
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 134 (03) : E110 - E112