Alterations of the bone dimension following immediate implant placement into extraction socket: systematic review and meta-analysis

被引:72
|
作者
Lee, Chun-Teh [1 ]
Chiu, Tzu-Shan [2 ]
Chuang, Sung-Kiang [3 ,4 ]
Tarnow, Dennis [2 ]
Stoupel, Janet [2 ]
机构
[1] Harvard Univ, Sch Dent Med, Dept Oral Med Infect & Immun, Div Periodontol, Boston, MA 02115 USA
[2] Columbia Univ, Coll Dent Med, Sect Oral & Diagnost Sci, Div Periodont, New York, NY 10032 USA
[3] Massachusetts Gen Hosp, Dept Oral & Maxillofacial Surg, Boston, MA 02114 USA
[4] Harvard Univ, Sch Dent Med, Boston, MA 02115 USA
关键词
bone dimension; immediate implant; meta-analysis; systematic review; BEAM COMPUTED-TOMOGRAPHY; HARD-TISSUE ALTERATIONS; ALVEOLAR RIDGE; MAXILLARY ANTERIOR; PROSPECTIVE COHORT; TOOTH EXTRACTION; CLINICAL-TRIAL; BUCCAL BONE; PRESERVATION; FLAP;
D O I
10.1111/jcpe.12276
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: This systematic review was aimed at analysing bone dimensional alterations within the first year following immediate implant placement. Materials and Methods: The electronic search was conducted using MEDLINE (PubMed), Cochrane Central Register of Controlled Trials (CENTRAL) and EMBASE from January 1980 to October 2013. Quality assessment of selected articles was performed using Cochrane Collaboration's tool or Newcastle-Ottawa scale according to the design of each study. A meta-analysis was performed to estimate bone dimensional reduction. Weighted mean differences in bone dimension between baseline and follow-up measurement were calculated. Subgroup analysis and mete-regression were conducted to evaluate the effects of different variables. Results: A total of 1348 articles were identified following the search process. Six studies were included in the present review. The weighted mean buccal horizontal bone dimensional reduction (BHDr) was 1.07 mm and buccal vertical bone dimensional reduction (BVDr) was 0.78 mm. The weighted mean palatal bone dimensional reduction was 0.62 mm horizontally (PHDr) and 0.50 mm vertically (PVDr). The initial thickness of the buccal alveolar plate (TB) of the socket was the only variable significantly correlated with BHDr and BVDr in meta-regression analysis. Conclusions: The bone dimensions of immediate implant sites demonstrated approximately 0.5-1.0 mm reduction in vertical and horizontal aspects 4-12 months following surgery. The results should be interpreted with care because of the data heterogeneity. The correlation of the socket buccal wall thickness, and other variables, with dimensional changes of the bony ridge should be investigated further in controlled clinical trials.
引用
收藏
页码:914 / 926
页数:13
相关论文
共 50 条
  • [31] Clinical Effectiveness of Immediate Implant Placement along with Demineralized Freeze-dried Bone Allograft - A Systematic Review and Meta-analysis
    Kalburgi, Veena
    Jain, Megha
    Bhole, Shravani
    Bagewadi, Shivanand
    Gupta, Sagar
    Katiyar, Rachna
    JOURNAL OF HEAD & NECK PHYSICIANS AND SURGEONS, 2024, 12 (01): : 18 - 27
  • [32] The effect of soft tissue augmentation on the clinical and radiographical outcomes following immediate implant placement and provisionalization: a systematic review and meta-analysis
    De Angelis, Paolo
    Manicone, Paolo Francesco
    Rella, Edoardo
    Liguori, Margherita Giorgia
    De Angelis, Silvio
    Tancredi, Sileno
    D'Addona, Antonio
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [33] The effect of soft tissue augmentation on the clinical and radiographical outcomes following immediate implant placement and provisionalization: a systematic review and meta-analysis
    Paolo De Angelis
    Paolo Francesco Manicone
    Edoardo Rella
    Margherita Giorgia Liguori
    Silvio De Angelis
    Sileno Tancredi
    Antonio D’Addona
    International Journal of Implant Dentistry, 7
  • [34] Immediate placement of implant into impacted maxillary canine extraction socket
    Cardaropoli, Daniele
    Debernardi, Cesare
    Cardaropoli, Giuseppe
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2007, 27 (01) : 71 - 77
  • [35] Immediate placement of implant in fresh extraction socket with early loading
    Singh, Archana
    Gupta, Aratee
    Yadav, Ashish
    Chaturvedi, T. P.
    Bhatnagar, Atul
    Singh, B. P.
    CONTEMPORARY CLINICAL DENTISTRY, 2012, 3 (06) : 219 - 222
  • [36] Clinical Outcomes of Immediate, Early, and Delayed Implant Placement in the Esthetic Zone: A Systematic Review and Meta-analysis
    Riachi, Emile
    Juodzbalys, Gintaras
    Maciuliene, Daiva
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (05) : e157 - e173
  • [37] Factors influencing ridge alterations following immediate implant placement into extraction sockets
    Ferrus, Jorge
    Cecchinato, Denis
    Pjetursson, E. Bjarni
    Lang, Niklaus P.
    Sanz, Mariano
    Lindhe, Jan
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (01) : 22 - 29
  • [38] Hard-tissue alterations following immediate implant placement in extraction sites
    Botticelli, D
    Berglundh, T
    Lindhe, J
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2004, 31 (10) : 820 - 828
  • [39] Bone envelope for implant placement after alveolar ridge preservation: a systematic review and meta-analysis
    Kai R. Fischer
    Alex Solderer
    Kristina Arlt
    Christian Heumann
    Chun Ching Liu
    Patrick R. Schmidlin
    International Journal of Implant Dentistry, 8
  • [40] Bone envelope for implant placement after alveolar ridge preservation: a systematic review and meta-analysis
    Fischer, Kai R.
    Solderer, Alex
    Arlt, Kristina
    Heumann, Christian
    Liu, Chun Ching
    Schmidlin, Patrick R.
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2022, 8 (01)