Potential Stable Low-Permeation Rate Standard Based on Micro-machined Silicon

被引:1
|
作者
Verwolf, Adrian [1 ]
Poling, Chris [2 ]
Barbosa, Nick [2 ]
White, Grady [2 ]
Rentz, Nikki [2 ]
机构
[1] Focused Labs LLC, Denver, CO 80239 USA
[2] NIST, Agcy US Dept Commerce, Boulder, CO 80305 USA
关键词
calibration; chilled mirror hygrometer; mass loss; permeation; Si; standard;
D O I
10.6028/jres.120.021
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Silicon wafers with micro-machined holes were evaluated for use as low-permeation-rate standard artifacts. Accuracy, stability, and reliability were assessed. Two independent experimental techniques for evaluating permeation were used: chilled mirror hygrometer and mass loss. The wafers exhibited a well-defined linear relationship between hole area and resultant water partial pressure for both techniques, although the mass loss curve exhibited a constant vertical offset from the hygrometer curve, attributed to water loss through the O-ring seal. In contrast to polymer permeation standards, Si wafers provided long-term reproducible permeation rates. However, they were also highly fragile, with most of them cracking during the course of the investigation.
引用
收藏
页码:329 / 342
页数:14
相关论文
共 50 条
  • [21] Research on Signal Demodulation Method of Silicon Micro-machined Gyroscope
    Yan, Qingwen
    Zhang, Fuxue
    Wu, Lifeng
    Sun, Chengxiang
    INFORMATION TECHNOLOGY FOR MANUFACTURING SYSTEMS, PTS 1 AND 2, 2010, : 11 - +
  • [22] Non-silicon micro-machined variable optical attenuator
    Zhou Hai-lin
    Dai Xu-han
    Ding Gui-fu
    Zhao Xiaolin
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2011: SENSOR AND MICROMACHINED OPTICAL DEVICE TECHNOLOGIES, 2011, 8191
  • [23] Sensitivity enhancement of a silicon micro-machined thermal flow sensor
    Roh, SC
    Choi, YM
    Kim, SY
    SENSORS AND ACTUATORS A-PHYSICAL, 2006, 128 (01) : 1 - 6
  • [24] Research on the signal of silicon micro-machined gyroscope for rotating carrier
    Xiao, Jianming
    Xu, Xiaosong
    Zhang, Fuxue
    PACIIA: 2008 PACIFIC-ASIA WORKSHOP ON COMPUTATIONAL INTELLIGENCE AND INDUSTRIAL APPLICATION, VOLS 1-3, PROCEEDINGS, 2008, : 814 - +
  • [25] A silicon based surface micro-machined distributed Bragg reflector for MEMS spectroscopic applications
    Tripathi, D. K.
    Silva, K. K. M. B. D.
    Rafiei, R.
    Bumgarner, J. W.
    Martyniuk, M.
    Nguyen, T.
    Antoszewski, J.
    Dell, J. M.
    Faraone, L.
    2013 8TH IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL AND INFORMATION SYSTEMS (ICIIS), 2013, : 289 - 293
  • [26] High Q Micro-machined Cavity Resonator Filter in Low-Cost Silicon Technology
    Gautier, William
    Schoenlinner, Bernhard
    Ziegler, Volker
    Prechtel, Ulrich
    Menzel, Wolfgang
    2008 EUROPEAN MICROWAVE CONFERENCE, VOLS 1-3, 2008, : 918 - +
  • [27] 100GHz Silicon-based micro-machined patch antenna and arrays
    Liu, Jingtian
    Chen, Shuming
    Xiao, Ke
    Chen, Xiaowen
    JOURNAL OF ENGINEERING-JOE, 2019, 2019 (19): : 5622 - 5625
  • [28] Sensitivity optimization of micro-machined thermo-resistive flow-rate sensors on silicon substrates
    Shaun, Ferdous
    Sarkar, Sreyash
    Marty, Frederic
    Poulichet, Patrick
    Cesar, William
    Nefzaoui, Elyes
    Bourouina, Tarik
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2018, 28 (07)
  • [29] An ultrasound source based on a micro-machined electromechanical resonator
    Huang, QT
    Kuratli, C
    ISCAS 96: 1996 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS - CIRCUITS AND SYSTEMS CONNECTING THE WORLD, VOL 4, 1996, : 348 - 351
  • [30] A bi-stable micro-machined switch employing three magnets
    Roshen, WA
    IECON 2005: THIRTY-FIRST ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-3, 2005, : 2123 - 2128