Histologic and Biomechanical Evaluation of the Effects of Implant Insertion Torque on Peri-Implant Bone Healing

被引:20
|
作者
Consolo, Ugo [1 ]
Travaglini, Domenico
Todisco, Marzio
Trisi, Paolo
Galli, Silvia
机构
[1] Univ Modena & Reggio Emilia, Fac Odontoiatria & Protesi Dent, I-41100 Modena, Italy
关键词
Dental implant; insertion torque; peri-implant bone; DENTAL IMPLANTS; DENSITY; MICROMOTION; INTERFACE; STABILITY;
D O I
10.1097/SCS.0b013e31827ca3cf
中图分类号
R61 [外科手术学];
学科分类号
摘要
The aim of this study was to evaluate histologically and biomechanically the peri-implant bone healing around implants placed with high torque after a follow-up of 8 and 12 weeks. A total of 12 implants were placed in the lower edge of the mandible of 2 sheep. In each sheep, 3 implants were placed with a low torque (<25 N center dot cm, LT group) as a control, and 3 implants were placed with a high insertion torque (maximum torque, HT group). The sheep were killed after 8 and 12 weeks of healing, and the implants were examined for removal torque, resonance frequency analysis, and histologic analysis. The mean insertion torque in the LT group was 24 N center dot cm, whereas it was 105.6 N center dot cm in HT. All the implants osseointegrated and histologic analysis showed similar aspects of the peri-implant bone tissue for both groups and both healing times. Mean removal torque values for LT implants were 159.5 and 131.5 N center dot cm after 8 and 12 weeks, respectively, whereas those for the HT were 140 and 120 N center dot cm at 8 and 12 weeks, respectively. Implant stability quotient values were 26.6 and 76 for the LT group and 74 and 76 for the HT group at 8 and 12 weeks, respectively. It could be concluded that high implant insertion torque does not induce adverse reaction in cortical bone and does not lead to implant failure.
引用
收藏
页码:860 / 865
页数:6
相关论文
共 50 条
  • [41] Effects of soft tissue punch size on the healing of peri-implant tissue in flapless implant surgery
    Lee, Du-Hyeong
    Choi, Byung-Ho
    Jeong, Seung-Mi
    Xuan, Feng
    Kim, Ha-Rang
    Mo, Dong-Yub
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2010, 109 (04): : 525 - 530
  • [42] Novel Biomarker Evaluation in Peri-Implant Crevicular Fluid as Disease Indicators for Peri-Implant Health
    Alsahhaf, Abdulaziz
    AlHamdan, Eman M.
    Vohra, Fahim
    Abduljabbar, Tariq
    Chaudhry, Ziaullah
    Kuyunov, Isaac
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2023, 13 (05) : 714 - 720
  • [43] Histologic and histomorphometric evaluation of peri-implant bone subjected to immediate loading:: An experimental study with Macaca fascicularis
    Romanos, GE
    Toh, CG
    Siar, CH
    Swaminathan, D
    Ong, AH
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2002, 17 (01) : 44 - 51
  • [44] The evaluation of peri-implant sulcus fluid osteocalcin, osteopontin, and osteonectin levels in peri-implant diseases
    Cakal, Oya Turkoglu
    Efeoglu, Candan
    Bozkurt, Emir
    JOURNAL OF PERIODONTOLOGY, 2018, 89 (04) : 418 - 423
  • [45] EVALUATION OF PERI-IMPLANT SULCULAR TEMPERATURE
    RAMS, TE
    ROBERTS, TW
    SLOTS, J
    JOURNAL OF CLINICAL PERIODONTOLOGY, 1993, 20 (06) : 465 - 468
  • [46] Evaluation of Biomechanical Health Degree of Peri-Implant Bone Through Finite Element Analysis: A First Approach
    Lin, Junxiong
    Zhang, Ge
    Jiang, Zhenyu
    Tang, Liqun
    Lian, Keqian
    INTERNATIONAL JOURNAL OF APPLIED MECHANICS, 2018, 10 (09)
  • [47] Evaluation of the Effects of Dual Antiplatelet Therapy on Guided Bone Regeneration in Peri-Implant Bone Defect
    Kobat, Mehmet Ali
    Dundar, Serkan
    Bozoglan, Alihan
    Gelen, Mehmet Ali
    Artas, Gokhan
    Kirtay, Mustafa
    Tasdemir, Ismail
    Karasu, Mehdi
    Habek, Osman
    JOURNAL OF CRANIOFACIAL SURGERY, 2023, 34 (05) : 1590 - 1594
  • [48] Evaluation of the Effects of Systemic Irisin Application on Guided Bone Regeneration in Peri-implant Bone Defects
    Bulmus, Ozgur
    Dundar, Serkan
    Bozoglan, Alihan
    Artas, Gokhan
    Kirtay, Mustafa
    Canpolat, Sinan
    JOURNAL OF CRANIOFACIAL SURGERY, 2022, 33 (07) : 2272 - 2275
  • [49] Evaluation of stress induced in peri-implant bone tissue by misfit in multi-implant prosthesis
    Natali, AN
    Pavan, PG
    Ruggero, AL
    DENTAL MATERIALS, 2006, 22 (04) : 388 - 395
  • [50] Effect of surgical techniques on primary implant stability and peri-implant bone
    Fanuscu, Mete I.
    Chang, Ting-Ling
    Akca, Kivanc
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 65 (12) : 2487 - 2491