Influence of the screw augmentation technique and a diameter increase on pedicle screw fixation in the osteoporotic spine: pullout versus fatigue testing

被引:86
|
作者
Kueny, Rebecca A. [1 ]
Kolb, Jan P. [2 ]
Lehmann, Wolfgang [2 ]
Pueschel, Klaus [3 ]
Morlock, Michael M. [1 ]
Huber, Gerd [1 ]
机构
[1] TUHH Hamburg Univ Technol, Inst Biomech, D-21073 Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Trauma Hand & Reconstruct Surg, D-20246 Hamburg, Germany
[3] Univ Med Ctr Hamburg Eppendorf, Inst Forens Med, D-22529 Hamburg, Germany
关键词
Pedicle screw; Spine; Cement augmentation; Pullout; Fatigue; Toggle; CEMENT AUGMENTATION; BIOMECHANICAL ANALYSIS; COMPLICATIONS; STRENGTH; LUMBAR; INSTRUMENTATION; STABILIZATION; VERTEBRAE; REVISION;
D O I
10.1007/s00586-014-3476-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
For posterior spinal stabilization, loosening of pedicle screws at the bone-screw interface is a clinical complication, especially in the osteoporotic population. Axial pullout testing is the standard pre-clinical testing method for new screw designs although it has questioned clinical relevance. The aim of this study was to determine the fixation strength of three current osteoporotic fixation techniques and to investigate whether or not pullout testing results can directly relate to those of the more physiologic fatigue testing. Thirty-nine osteoporotic, human lumbar vertebrae were instrumented with pedicle screws according to four treatment groups: (1) screw only (control), (2) prefilled augmentation, (3) screw injected augmentation, and (4) unaugmented screws with an increased diameter. Toggle testing was first performed on one pedicle, using a cranial-caudal sinusoidal, cyclic (1.0 Hz) fatigue loading applied at the screw head. The initial compressive forces ranged from 25 to 75 N. Peak force increased stepwise by 25 N every 250 cycles until a 5.4-mm screw head displacement. The contralateral screw then underwent pure axial pullout (5 mm/min). When compared to the control group, screw injected augmentation increased fatigue force (27 %, p = 0.045) while prefilled augmentation reduced fatigue force (-7 %, p = 0.73). Both augmentation techniques increased pullout force compared to the control (ps < 0.04). Increasing the screw diameter by 1 mm increased pullout force (24 %, p = 0.19), fatigue force (5 %, p = 0.73), and induced the least stiffness loss (-29 %) from control. For the osteoporotic spine, screw injected augmentation showed the best biomechanical stability. Although pullout testing was more sensitive, the differences observed were not reflected in the more physiological fatigue testing, thus casting further doubt on the clinical relevance of pullout testing.
引用
收藏
页码:2196 / 2202
页数:7
相关论文
共 50 条
  • [41] A new technique of bone cement augmentation via the disc space for percutaneous pedicle screw fixation
    Park, Chang Kyu
    Park, Choon Keun
    Lee, Dong Chan
    Lee, Dong Geun
    JOURNAL OF NEUROSURGERY-SPINE, 2016, 24 (01) : 16 - 19
  • [42] A PEDICLE SCREW BRIDGING DEVICE FOR POSTERIOR SEGMENTAL FIXATION OF THE SPINE - PRELIMINARY MECHANICAL TESTING RESULTS
    RAHMATALLA, AT
    HASTINGS, GW
    DOVE, J
    CRAWSHAW, AH
    JOURNAL OF BIOMEDICAL ENGINEERING, 1991, 13 (02): : 97 - 102
  • [43] Accuracy of Freehand Versus Modified Funnel Technique for Pedicle Screw Insertion in the Thoracic Spine
    Kilicaslan, Omer Faruk
    Tokgoz, Mehmet Ali
    Butun, Sevket
    Nabi, Vugar
    Akalin, Serdar
    TURKISH NEUROSURGERY, 2021, 31 (05) : 795 - 802
  • [44] Reinforcement of Percutaneous Pedicle Screw Fixation with Hydroxyapatite Granules in Patients with Osteoporotic Spine: Biomechanical Performance and Clinical Outcomes
    Kanno, Haruo
    Onoda, Yoshito
    Hashimoto, Ko
    Aizawa, Toshimi
    Ozawa, Hiroshi
    MEDICINA-LITHUANIA, 2022, 58 (05):
  • [45] Influence of Hydroxyapatite Stick on Pedicle Screw Fixation in Degenerative Lumbar Spine Biomechanical and Radiologic Study
    Shin, Sung Joon
    Lee, Ji-Ho
    Lee, Jae Hyup
    CLINICAL SPINE SURGERY, 2017, 30 (06): : E819 - E826
  • [46] Flexion-distraction injuries of the thoracolumbar spine: open fusion versus percutaneous pedicle screw fixation
    Grossbach, Andrew J.
    Dahdaleh, Nader S.
    Abel, Taylor J.
    Woods, Gregory D.
    Dlouhy, Brian J.
    Hitchon, Patrick W.
    NEUROSURGICAL FOCUS, 2013, 35 (02)
  • [47] Pedicle screw motion in the osteoporotic spine after augmentation with laminar hooks, sublaminar wires, or calcium phosphate cement: A comparative analysis
    Tan, JS
    Kwon, BK
    Dvorak, MF
    Fisher, CG
    Oxland, TR
    SPINE, 2004, 29 (16) : 1723 - 1730
  • [48] Effect and potential risks of using multilevel cement-augmented pedicle screw fixation in osteoporotic spine with lumbar degenerative disease
    Tang, Yong-chao
    Guo, Hui-zhi
    Guo, Dan-qing
    Luo, Pei-jie
    Li, Yong-xian
    Mo, Guo-ye
    Ma, Yan-huai
    Peng, Jian-cheng
    Liang, De
    Zhang, Shun-cong
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [49] Effect and potential risks of using multilevel cement-augmented pedicle screw fixation in osteoporotic spine with lumbar degenerative disease
    Yong-chao Tang
    Hui-zhi Guo
    Dan-qing Guo
    Pei-jie Luo
    Yong-xian Li
    Guo-ye Mo
    Yan-huai Ma
    Jian-cheng Peng
    De Liang
    Shun-cong Zhang
    BMC Musculoskeletal Disorders, 21
  • [50] Biomechanical Comparison of Corticopedicular Spine Fixation versus Pedicle Screw Fixation in a Lumbar Degenerative Spondylolisthesis Finite Element Analysis Model
    Farooqi, Ali S.
    Narayanan, Rajkishen
    Canseco, Jose A.
    Vaccaro, Alexander R.
    WORLD NEUROSURGERY, 2024, 190 : E129 - E136