Influence of the screw augmentation technique and a diameter increase on pedicle screw fixation in the osteoporotic spine: pullout versus fatigue testing

被引:86
|
作者
Kueny, Rebecca A. [1 ]
Kolb, Jan P. [2 ]
Lehmann, Wolfgang [2 ]
Pueschel, Klaus [3 ]
Morlock, Michael M. [1 ]
Huber, Gerd [1 ]
机构
[1] TUHH Hamburg Univ Technol, Inst Biomech, D-21073 Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Trauma Hand & Reconstruct Surg, D-20246 Hamburg, Germany
[3] Univ Med Ctr Hamburg Eppendorf, Inst Forens Med, D-22529 Hamburg, Germany
关键词
Pedicle screw; Spine; Cement augmentation; Pullout; Fatigue; Toggle; CEMENT AUGMENTATION; BIOMECHANICAL ANALYSIS; COMPLICATIONS; STRENGTH; LUMBAR; INSTRUMENTATION; STABILIZATION; VERTEBRAE; REVISION;
D O I
10.1007/s00586-014-3476-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
For posterior spinal stabilization, loosening of pedicle screws at the bone-screw interface is a clinical complication, especially in the osteoporotic population. Axial pullout testing is the standard pre-clinical testing method for new screw designs although it has questioned clinical relevance. The aim of this study was to determine the fixation strength of three current osteoporotic fixation techniques and to investigate whether or not pullout testing results can directly relate to those of the more physiologic fatigue testing. Thirty-nine osteoporotic, human lumbar vertebrae were instrumented with pedicle screws according to four treatment groups: (1) screw only (control), (2) prefilled augmentation, (3) screw injected augmentation, and (4) unaugmented screws with an increased diameter. Toggle testing was first performed on one pedicle, using a cranial-caudal sinusoidal, cyclic (1.0 Hz) fatigue loading applied at the screw head. The initial compressive forces ranged from 25 to 75 N. Peak force increased stepwise by 25 N every 250 cycles until a 5.4-mm screw head displacement. The contralateral screw then underwent pure axial pullout (5 mm/min). When compared to the control group, screw injected augmentation increased fatigue force (27 %, p = 0.045) while prefilled augmentation reduced fatigue force (-7 %, p = 0.73). Both augmentation techniques increased pullout force compared to the control (ps < 0.04). Increasing the screw diameter by 1 mm increased pullout force (24 %, p = 0.19), fatigue force (5 %, p = 0.73), and induced the least stiffness loss (-29 %) from control. For the osteoporotic spine, screw injected augmentation showed the best biomechanical stability. Although pullout testing was more sensitive, the differences observed were not reflected in the more physiological fatigue testing, thus casting further doubt on the clinical relevance of pullout testing.
引用
收藏
页码:2196 / 2202
页数:7
相关论文
共 50 条
  • [31] Krag Versus Caudad Trajectory Technique for Pedicle Screw Insertion in Osteoporotic Vertebrae
    Yuan, Qiang
    Han, Xiaoguang
    Han, Xiao
    He, Da
    Liu, Bo
    Tian, Wei
    SPINE, 2014, 39 (26B) : B27 - B35
  • [32] Cement augmentation of pedicle screw fixation in spine surgery among patients with osteoporosis: a systematic review
    Alshehri, Shaker Hassan Salem
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2019, 10 (05): : 641 - 645
  • [33] A NOVEL PEDICLE SCREW FOR PMMA AUGMENTATION: A PRELIMINARY STUDY OF PULL-OUT TEST IN OSTEOPOROTIC SPINE
    Soshi, S.
    Kida, Y.
    Ushiku, C.
    Marumo, K.
    Spengler, D.
    OSTEOPOROSIS INTERNATIONAL, 2010, 21 : 367 - 367
  • [34] Surgical Strategies to Improve Fixation in the Osteoporotic Spine: The Effects of Tapping, Cement Augmentation, and Screw Trajectory
    Kuhns, Craig A.
    Reiter, Michael
    Pfeiffer, Ferris
    Choma, Theodore J.
    GLOBAL SPINE JOURNAL, 2014, 4 (01) : 47 - 53
  • [35] Impact of Screw Type on Kyphotic Deformity Correction after Spine Fracture Fixation: Cannulated versus Solid Pedicle Screw
    Arbash, Mahmood Ali
    Parambathkandi, Ashik Mohsin
    Baco, Abdul Moeen
    Alhammoud, Abduljabbar
    ASIAN SPINE JOURNAL, 2018, 12 (06) : 1053 - 1059
  • [36] Pedicle Screw Design and Cement Augmentation in Osteoporotic Vertebrae Effects of Fenestrations and Cement Viscosity on Fixation and Extraction
    Choma, Theodore J.
    Pfeiffer, Ferris M.
    Swope, Ryan W.
    Hirner, Jesse P.
    SPINE, 2012, 37 (26) : E1628 - E1632
  • [37] Efficacy of novel-concept pedicle screw fixation augmented with calcium phosphate cement in the osteoporotic spine
    Yazu, N
    Kin, A
    Kosaka, R
    Kinoshita, M
    Abe, M
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2005, 10 (01) : 56 - 61
  • [38] Improving fixation strength of pedicle screw by microarc oxidation treatment: An experimental study of osteoporotic spine in sheep
    Shi, Lei
    Wang, Ling
    Zhang, Yang
    Guo, Zheng
    Wu, Zi-xiang
    Liu, Da
    Gao, Ming-xuan
    Chen, Huan
    Fu, Suo-chao
    Lei, Wei
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2012, 30 (08) : 1296 - 1303
  • [39] Pedicle Screw Fixation Study in Immature Porcine Spines to Improve Pullout Resistance during Animal Testing
    Le Cann, Sophie
    Cachon, Thibaut
    Viguier, Eric
    Miladi, Lotfi
    Odent, Thierry
    Rossi, Jean-Marie
    Chabrand, Patrick
    PLOS ONE, 2015, 10 (10):
  • [40] A comparative study of pedicle screw fixation in dorsolumbar spine by freehand versus image-assisted technique: A cadaveric study
    Agarwal, Archit
    Chauhan, Vijendra
    Singh, Deepa
    Shailendra, Raghuvanshi
    Maheshwari, Rajesh
    Juyal, Anil
    INDIAN JOURNAL OF ORTHOPAEDICS, 2016, 50 (03) : 243 - 249