Design of a Hip Joint Simulator According to the ISO 14242

被引:0
|
作者
Galanis, Nikolaos I. [1 ]
Manolakos, Dimitrios E. [1 ]
机构
[1] Natl Tech Univ Athens, Athens, Greece
关键词
Hip Joint Simulator; ISO; 14242; flexion; adduction; outwards rotation; ON-METAL JOINTS; TRACK ANALYSIS; WEAR; PERFORMANCE; HEADS;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Wear and simulator testing are complicated tasks. Controlled wear testing should not be routinely done to qualify a material, but rather to elucidate wear mechanisms. It, generally, may be described as a machine used to test a joint replacement under conditions approximating those occurring in the human body. Simulator tests, on the other hand, can be used to conduct accelerated protocols that replicate/simulate particularly extreme conditions, thereby establishing the limits of performance for the material. The present paper is dealing with the study of the most common simulators, and the design of a new one that has been analysed by a CAD software to meet the aforementioned study and the ISO 14242 Standard recommendations.
引用
收藏
页码:2088 / 2093
页数:6
相关论文
共 50 条
  • [31] A simulated synovial fluid for wear characterization of artificial hip joints by a hip joint simulator
    Takadama, H
    Mizuno, M
    BIOCERAMICS 18, PTS 1 AND 2, 2006, 309-311 : 1273 - 1276
  • [32] Human hip joint center analysis for biomechanical design of a hip joint exoskeleton
    Wei Yang
    Can-jun Yang
    Ting Xu
    Frontiers of Information Technology & Electronic Engineering, 2016, 17 : 792 - 802
  • [33] A Study of the Effect of the Femoral Head Diameter on Prosthetic Hip Joint Dislocation Using a Hip-Joint Motion Simulator
    Kiguchi, Kazuo
    Horie, Toru
    Yamashita, Akira
    Ueno, Masaru
    Kobayashi, Tsuneyuki
    Mawatari, Masaaki
    Hotokebuchi, Takao
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 6058 - +
  • [34] Human hip joint center analysis for biomechanical design of a hip joint exoskeleton
    Yang, Wei
    Yang, Can-jun
    Xu, Ting
    FRONTIERS OF INFORMATION TECHNOLOGY & ELECTRONIC ENGINEERING, 2016, 17 (08) : 792 - 802
  • [35] Design and Validation of a Simulator for Equine Joint Injections
    Fox, Victoria
    Sinclair, Charlotte
    Bolt, David M.
    Lowe, John
    Weller, Renate
    JOURNAL OF VETERINARY MEDICAL EDUCATION, 2013, 40 (02) : 152 - 157
  • [36] Design and evaluation of a hip prosthesis simulator: A technical note
    Fanous, Amir
    Botros, Michael
    Gholizadeh, Hossein
    Baddour, Natalie
    Lemaire, Edward D.
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2023, 47 (04) : 443 - 446
  • [37] A multi-station hip joint simulator study and wear characterization of commercial hip endoprostheses
    Jono, K
    Takigawa, Y
    Takadama, H
    Mizuno, M
    Nakamura, T
    27TH INTERNATIONAL COCOA BEACH CONFERENCE ON ADVANCED CERAMICS AND COMPOSITES: A, 2003, 24 (03): : 255 - 260
  • [38] Three-axis hip joint simulator for wear and friction studies on total hip prostheses
    Saikko, Vesa O.
    Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1996, 210 (03) : 175 - 185
  • [39] A biomimetic hip joint simulator and its application in in vitro study of the integrity of replacement cemented hip
    Chao-zong Liu
    S. M. Green
    N. D. Watkins
    A. W. McCaskie
    Journal of Bionic Engineering, 2005, 2 (4) : 177 - 185
  • [40] Biotribological study of multilayer coated metal-on-metal hip prostheses in a hip joint simulator
    Ortega-Saenz, J. A.
    Alvarez-Vera, M.
    Hernandez-Rodriguez, M. A. L.
    WEAR, 2013, 301 (1-2) : 234 - 242