Development of a ZnS (Ag)-Silicon Photomultiplier Fast Neutron Detector for the Neutron Hodoscope at TREAT

被引:0
|
作者
Wonders, Marc A. [1 ]
Chichester, David L. [2 ]
Flaska, Marek [1 ]
机构
[1] Penn State Univ, Ken & Mary Alice Dept Nucl Engn, University Pk, PA 16802 USA
[2] Idaho Natl Lab, Idaho Falls, ID 83402 USA
关键词
D O I
10.1109/nss/mic42101.2019.9059918
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The Transient Reactor Test (TREAT) Facility at Idaho National Laboratory is being restored to support the mission of advanced reactor and fuel development in the United States. A key part of this restoration is the fast neutron hodoscope which images the fuel tested during extreme transient conditions. Traditionally, this testing has been done with ZnS(Ag)-based proton recoil scintillators (PRS) coupled to photomultiplier tubes (PMTs). Recently, silicon photomultipliers (SiPMs) have emerged as a new candidate to replace PMTs in this application. This work develops, tests, and evaluates a SiPM-based PRS detector for incorporation into the updated fast neutron hodoscope, also known as the Fuel Motion Monitoring System (FMMS). The primary characteristics to be optimized are the gamma rejection and neutron detection efficiency of the detector, which will be done using a pulse shape discrimination (PSD) technique. Five types of SiPMs are tested and compared using standard PSD figures of merit, and the Hamamatsu 6075 is selected as the ideal SiPM. PSD performance for the Hamamatsu 6075 SiPM with the PRS detector is also characterized as a function of temperature. Finally, the gamma rejection and neutron detection efficiency are characterized for this SiPM and benchmarked to the traditional PMT-based PRS detectors. Both light sensors exhibit excellent gamma rejection and neutron detection efficiency. However, the SiPM-based detectors exhibit a greater ability to discriminate neutrons from gammas based only on pulse height which is important in operating at high count rates. This motivates the development of a SiPM-based PRS detector in a fully self-contained assembly to test directly with TREAT or in similar environments.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] High Data-Rate Neutron-Sensitive Pixelated Detector Using Silicon Photomultiplier
    Chong, Su-Ann
    Riedel, Richard
    Visscher, Theodore
    Dohanue, Cornelius, Jr.
    Hannan, Bruce
    Montcalm, Christopher
    Hayward, Jason
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [42] Development of a multi-channel gamma-blind fast neutron detector based on wavelength shifting fibers embedded in a ZnS:Ag epoxy mixture
    Wolfertz, Alexander
    Adams, Robert
    Perret, Gregory
    Lamirand, Vincent
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1053
  • [43] A fast-neutron detector based on single-crystalline silicon
    Varlachev, V. A.
    Solodovnikov, E. S.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2008, 51 (02) : 171 - 174
  • [44] A fast-neutron detector based on single-crystalline silicon
    V. A. Varlachev
    E. S. Solodovnikov
    Instruments and Experimental Techniques, 2008, 51 : 171 - 174
  • [45] Study on Performance of 6LiF/ZnS(Ag) Scintillation Screen for Scintillator Neutron Detector in China Spallation Neutron Source
    Jiang J.
    Huang C.
    Wei Y.
    Tang B.
    Yu Q.
    Zhou S.
    Cai X.
    Deng Q.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2023, 57 (08): : 1650 - 1657
  • [46] PARAMETERS OF ZNS(AG) SCINTILLATORS FOR NEUTRON RECORDING
    SOKOLOVA, ZY
    CHERNYAE.VB
    SOVIET ATOMIC ENERGY-USSR, 1970, 28 (02): : 205 - &
  • [47] ZNS(AG) PHOSPHOR MIXTURES FOR NEUTRON DETECTION
    KOONTZ, PG
    KEEPIN, GR
    ASHLEY, JE
    PHYSICAL REVIEW, 1954, 96 (03): : 862 - 862
  • [48] Development of diamond detector as fast neutron spectroscopy in the EAST tokamak
    Lin, S. Y.
    Zhou, R. J.
    Artemev, K. K.
    Zhang, J. Z.
    Zhao, J. L.
    Zhong, G. Q.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (07):
  • [49] SIMULATION OF RESPONSE FUNCTIONS OF FAST NEUTRON SENSORS AND DEVELOPMENT OF THIN NEUTRON SILICON SENSOR
    Takada, Masashi
    Nakamura, Takashi
    Matsuda, Mikihiko
    Nunomiya, Tomoya
    RADIATION PROTECTION DOSIMETRY, 2014, 161 (1-4) : 295 - 298
  • [50] A novel photomultiplier tube neutron time-of-flight detector
    Glebov, V. Yu.
    Stoeckl, C.
    Forrest, C. J.
    Knauer, J. P.
    Mannion, O. M.
    Romanofsky, M. H.
    Sangster, T. C.
    Regan, S. P.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (01):