Comparative Study of Ion Interaction Reagents for the Separation of Lanthanides by Reversed-Phase High Performance Liquid Chromatography (RP-HPLC)

被引:10
|
作者
Jaison, P. G. [1 ]
Kumar, Pranaw [1 ]
Telmore, Vijay M. [1 ]
Aggarwal, Suresh K. [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Fuel Chem, Bombay 400085, Maharashtra, India
关键词
HPLC; Ion interaction reagents; Lanthanides; Modification; Resolution; Reversed-phase; RARE-EARTH-ELEMENTS; URANIUM-DIOXIDE FUELS; METAL-IONS; EXCHANGE CHROMATOGRAPHY; GEOLOGICAL SAMPLES; COATED COLUMNS; HIGH-PURITY; THORIUM; GABON; MASS;
D O I
10.1080/10826070903163230
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A study of two ion interaction reagents (IIRs) viz. n-octadecane sulphonate (C-18-sulphonate) and eicosyl sulphate (C-20-sulphate) was carried out for the separation of lanthanides by reversed-phase high performance liquid chromatography (RP-HPLC). The objective of the study was to identify a suitable IIR offering long term adsorption onto the RP column, thereby obviating the need to introduce the IIR in the mobile phase during the separation of lanthanides. This avoids the rigorous treatment of purified fractions before their mass spectrometric analysis. Resolution was used for comparing different IIRs for separation of lanthanides under identical chromatographic conditions, employing alpha-hydroxy isobutyric acid (alpha-HIBA) as an eluent. The volume and composition of IIR solution required for the modification of the column, as well as their long term adsorption, were studied. Columns coated with C-18-sulphonate and C-20-sulphate allowed the separation of lanthanides without introducing the IIR in the mobile phase. Between these two IIRs, C-18-sulphonate offered higher resolution and provided good long term adsorption stability. A RP column modified with C-18-sulphonate, as per the optimised procedure, was used for the separation of lanthanides from a geological reference sample without the need to include IIR into the mobile phase.
引用
收藏
页码:2146 / 2163
页数:18
相关论文
共 50 条
  • [31] Evaluation of DNA synthesis quality using ion-pair reversed-phase high performance liquid chromatography (IP-RP-HPLC)
    Fountain, KJ
    Gilar, M
    Gebler, JC
    LC GC NORTH AMERICA, 2004, : 26 - 27
  • [32] Preparation and separation of metallobacteriochlorophyll a by reversed-phase high-performance liquid chromatography
    Inoue, H
    Nonomura, Y
    Ashizawa, A
    Tajima, I
    Nomura, M
    Nakamura, N
    Yoshioka, N
    CHROMATOGRAPHIA, 1996, 43 (7-8) : 361 - 364
  • [33] SEPARATION OF PEPTIDES BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HERMODSON, M
    MAHONEY, WC
    METHODS IN ENZYMOLOGY, 1983, 91 : 352 - 359
  • [34] SEPARATION OF DESULFOGLUCOSINOLATES BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MINCHINTON, I
    SANG, J
    BURKE, D
    TRUSCOTT, RJW
    JOURNAL OF CHROMATOGRAPHY, 1982, 247 (01): : 141 - 148
  • [35] SEPARATION OF FLAVONOIDS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    VADECASTEELE, K
    GEIGER, H
    VANSUMERE, CF
    JOURNAL OF CHROMATOGRAPHY, 1982, 240 (01): : 81 - 94
  • [37] SEPARATION OF MONOACYLGLYCEROLS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SEMPORE, BG
    BEZARD, JA
    JOURNAL OF CHROMATOGRAPHY, 1992, 596 (02): : 185 - 195
  • [38] SEPARATION OF INSECTICIDES BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    CABRAS, P
    MELONI, M
    PIRISI, FM
    JOURNAL OF CHROMATOGRAPHY, 1979, 176 (03): : 473 - 477
  • [39] SEPARATION OF NONAPEPTIDES BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KRUMMEN, K
    FREI, RW
    JOURNAL OF CHROMATOGRAPHY, 1977, 132 (01): : 27 - 36
  • [40] SEPARATION OF CYTOKININS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HOLLAND, JA
    MCKERRELL, EH
    FUELL, KJ
    BURROWS, WJ
    JOURNAL OF CHROMATOGRAPHY, 1978, 166 (02): : 545 - 553