A study of two ion interaction reagents (IIRs) viz. n-octadecane sulphonate (C-18-sulphonate) and eicosyl sulphate (C-20-sulphate) was carried out for the separation of lanthanides by reversed-phase high performance liquid chromatography (RP-HPLC). The objective of the study was to identify a suitable IIR offering long term adsorption onto the RP column, thereby obviating the need to introduce the IIR in the mobile phase during the separation of lanthanides. This avoids the rigorous treatment of purified fractions before their mass spectrometric analysis. Resolution was used for comparing different IIRs for separation of lanthanides under identical chromatographic conditions, employing alpha-hydroxy isobutyric acid (alpha-HIBA) as an eluent. The volume and composition of IIR solution required for the modification of the column, as well as their long term adsorption, were studied. Columns coated with C-18-sulphonate and C-20-sulphate allowed the separation of lanthanides without introducing the IIR in the mobile phase. Between these two IIRs, C-18-sulphonate offered higher resolution and provided good long term adsorption stability. A RP column modified with C-18-sulphonate, as per the optimised procedure, was used for the separation of lanthanides from a geological reference sample without the need to include IIR into the mobile phase.
引用
收藏
页码:2146 / 2163
页数:18
相关论文
共 50 条
  • [21] Development and validation of reversed phase high performance liquid chromatography (RP-HPLC) for quantification of captopril in rabbit plasma
    Rasool, Muhammad Fawad
    Qureshi, Umbreen Fatima
    Ranjha, Nazar Muhammad
    Imran, Imran
    Nisa, Mouqadus Un
    Majeed, Abdul
    ACTA CHROMATOGRAPHICA, 2021, 33 (04) : 315 - 321
  • [22] DEVELOPMENT AND VALIDATION OF REPAGLINIDE BY REVERSED PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (RP-HPLC) IN TABLET DOSAGE FORMS
    Begum, Ayesha K.
    Pamu, Sandhya
    Kodali, Geetha
    Kasu, Pavani
    INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2014, 1 (03): : 142 - 150
  • [23] Lipophilicity measurement by reversed-phase high-performance liquid chromatography (RP-HPLC): A comparison of two stationary phases based on retention mechanisms
    Liu, XL
    Tanaka, H
    Yamauchi, A
    Testa, B
    Chuman, H
    HELVETICA CHIMICA ACTA, 2004, 87 (11) : 2866 - 2876
  • [24] Rapid and Simple Reversed-Phase High-Performance Liquid Chromatography (RP-HPLC) Method for Simultaneous Quantifications of Triazole Antifungals in Human Serum
    Hansraj Choudhary
    Shreya Singh
    Rachna Singh
    Ritesh Agarwal
    Harsimran Kaur
    Anup Ghosh
    Arunaloke Chakrabarti
    Shivaprakash M. Rudramurthy
    Mycopathologia, 2021, 186 : 27 - 39
  • [25] Simultaneous determination of ibuprofen and diphenhydramine HCl in orally disintegrating tablets and its dissolution by reversed-phase high performance liquid chromatography (RP-HPLC)
    Ge, Z. K.
    Luo, Y. H.
    Zhao, X. Y.
    Zhang, Y. J.
    Zhang, H.
    Tian, C. C.
    AFRICAN JOURNAL OF PHARMACY AND PHARMACOLOGY, 2011, 5 (18): : 2100 - 2105
  • [26] Rapid and Simple Reversed-Phase High-Performance Liquid Chromatography (RP-HPLC) Method for Simultaneous Quantifications of Triazole Antifungals in Human Serum
    Choudhary, Hansraj
    Singh, Shreya
    Singh, Rachna
    Agarwal, Ritesh
    Kaur, Harsimran
    Ghosh, Anup
    Chakrabarti, Arunaloke
    Rudramurthy, Shivaprakash M.
    MYCOPATHOLOGIA, 2021, 186 (01) : 27 - 39
  • [27] QUANTITATIVE DETERMINATION OF ETORICOXIB AND PARACETAMOL IN PHARMACEUTICAL DOSAGE FORM AND IN-VITRO COMPARISON BY REVERSED-PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (RP-HPLC)
    Zaveri, Maitreyi
    Khandhar, Amit
    ASIAN JOURNAL OF PHARMACEUTICAL RESEARCH AND HEALTH CARE, 2010, 2 (04) : 307 - 313
  • [28] Simultaneous determination of seven effective constituents in the leaves of bamboo by reversed phase high performance liquid chromatography (RP-HPLC)
    Jin, Yong-chun
    Liu, Hua-liang
    Yuan, Ke
    JOURNAL OF MEDICINAL PLANTS RESEARCH, 2011, 5 (23): : 5630 - 5635
  • [29] SEPARATION OF METAL-CYANIDE COMPLEXES BY REVERSED-PHASE ION-INTERACTION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    GIROUX, L
    BARKLEY, DJ
    CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1994, 72 (02): : 269 - 273
  • [30] SEPARATION OF METHOXYANILINES BY COMPETING-ION REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HILL, RA
    JOURNAL OF CHROMATOGRAPHY, 1984, 316 (DEC): : 227 - 230